메뉴 건너뛰기




Volumn 13, Issue 2, 2010, Pages 121-125

Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope

Author keywords

Elasticity Vascular tissue; Extracellular matrix; Mapping; Scanning haptic microscope

Indexed keywords

COLLAGEN FIBRIL; ELASTIN; WATER;

EID: 77956493944     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-010-0503-2     Document Type: Article
Times cited : (13)

References (17)
  • 2
    • 33845321780 scopus 로고    scopus 로고
    • A pinch elastometer for soft tissue
    • Harrison S, Bush M, Petros P. A pinch elastometer for soft tissue. Med Eng Phys. 2007;29:307-15.
    • (2007) Med Eng Phys , vol.29 , pp. 307-315
    • Harrison, S.1    Bush, M.2    Petros, P.3
  • 5
    • 33746784797 scopus 로고    scopus 로고
    • Elastic response, buckling, and instability of microtubules underradial indentation
    • Schaap A, Carrasco C, Pablo P, MacKintosh F, Schmidt C. Elastic response, buckling, and instability of microtubules underradial indentation. Biophys J. 2006;91:1521-31.
    • (2006) Biophys J , vol.91 , pp. 1521-1531
    • Schaap, A.1    Carrasco, C.2    Pablo, P.3    MacKintosh, F.4    Schmidt, C.5
  • 6
    • 77956489306 scopus 로고    scopus 로고
    • Assessment of elasticity and topography of Aspergillus nidulans spores via atomic force microscopy
    • Zhao L, Schaefer D, Marten M. Assessment of elasticity and topography of Aspergillus nidulans spores via atomic force microscopy. Biophys J. 2007;92:955-60.
    • (2007) Biophys J , vol.92 , pp. 955-960
    • Zhao, L.1    Schaefer, D.2    Marten, M.3
  • 7
    • 2142765353 scopus 로고    scopus 로고
    • Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy
    • Stolz M, Raiteri R, Daniels A, Landingham M, Baschong W, Aebi U. Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. Biophys J. 2004;86: 3269-83.
    • (2004) Biophys J , vol.86 , pp. 3269-3283
    • Stolz, M.1    Raiteri, R.2    Daniels, A.3    Landingham, M.4    Baschong, W.5    Aebi, U.6
  • 8
    • 33751558937 scopus 로고    scopus 로고
    • A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues
    • Jacot J, Dianis S, Schnall J, Wong J. A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues. J Biomed Mater Res. 2006; 79A:485-94.
    • (2006) J Biomed Mater Res , vol.79 A , pp. 485-494
    • Jacot, J.1    Dianis, S.2    Schnall, J.3    Wong, J.4
  • 9
    • 0346996699 scopus 로고    scopus 로고
    • Micro-mechanical platform for the characterization of the elastic properties of the ovum via uniaxial measurement
    • Murayama Y, Constantinou C, Omata S. Micro-mechanical platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67-72.
    • (2004) J Biomech , vol.37 , pp. 67-72
    • Murayama, Y.1    Constantinou, C.2    Omata, S.3
  • 10
    • 17644381242 scopus 로고    scopus 로고
    • Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology
    • Murayama Y, Constantinou C, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sens Actuators A. 2005; 120:543-9.
    • (2005) Sens Actuators A , vol.120 , pp. 543-549
    • Murayama, Y.1    Constantinou, C.2    Omata, S.3
  • 12
    • 74249109947 scopus 로고    scopus 로고
    • Tactile mapping system: A novel imaging technology for surface topography and elasticity of tissues or organs
    • Oie T, Suzuki H, Fukuda T, Murayama Y, Omata S, Kanda K, Nakayama Y. Tactile mapping system: a novel imaging technology for surface topography and elasticity of tissues or organs. Innovations. 2009;4:345-50.
    • (2009) Innovations , vol.4 , pp. 345-350
    • Oie, T.1    Suzuki, H.2    Fukuda, T.3    Murayama, Y.4    Omata, S.5    Kanda, K.6    Nakayama, Y.7
  • 13
    • 33947504944 scopus 로고    scopus 로고
    • Development of biotube vascular grafts incorporating cuffs for easy implantation
    • Watanabe T, Kanda K, Ishibashi-Umeda H, Yaku H, Nakayama Y. Development of biotube vascular grafts incorporating cuffs for easy implantation. J Artif Organs. 2007;10:10-5.
    • (2007) J Artif Organs , vol.10 , pp. 10-15
    • Watanabe, T.1    Kanda, K.2    Ishibashi-Umeda, H.3    Yaku, H.4    Nakayama, Y.5
  • 14
    • 74849086723 scopus 로고    scopus 로고
    • Autologous small-caliber "biotube" vascular grafts with arg-atroban loading: A histomorphological examination after implantation to rabbits
    • Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Autologous small-caliber "Biotube" vascular grafts with arg-atroban loading: a histomorphological examination after implantation to rabbits. J Biomed Mater Res B. 2010;92B:236-42.
    • (2010) J Biomed Mater Res B , vol.92 B , pp. 236-242
    • Watanabe, T.1    Kanda, K.2    Ishibashi-Ueda, H.3    Yaku, H.4    Nakayama, Y.5
  • 15
    • 34250785137 scopus 로고    scopus 로고
    • Development of an in vivo tissue-engineered autologous heart valve (the Biovalve): Preparation of prototype model
    • Hayashida K, Kanda K, Yaku H, Ando J, Nakayama Y. Development of an in vivo tissue-engineered autologous heart valve (the Biovalve): preparation of prototype model. J Thorac Cardiovasc Surg. 2007;134:152-9.
    • (2007) J Thorac Cardiovasc Surg , vol.134 , pp. 152-159
    • Hayashida, K.1    Kanda, K.2    Yaku, H.3    Ando, J.4    Nakayama, Y.5
  • 16
    • 77956475423 scopus 로고    scopus 로고
    • Development of a completely autologous valved-conduit with the sinus of valsalva (BIOVALVE) using in body tissue architecture technology: A pilot study in pulmonary valve replacement in a beagle model
    • [Epub ahead of print]
    • Yamanami M, Yahata Y, Uechi M, Fujiwara M, Ishibashi-Ueda Hatsue, Kanda K, Watanabe T, Tajikawa T, Ohba K, Yaku H, Nakayama Y. (2010) Development of a completely autologous valved-conduit with the sinus of valsalva (BIOVALVE) using in body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model. Circulation [Epub ahead of print]
    • (2010) Circulation
    • Yamanami, M.1    Yahata, Y.2    Uechi, M.3    Fujiwara, M.4    Hatsue, I.5    Kanda, K.6    Watanabe, T.7    Tajikawa, T.8    Ohba, K.9    Yaku, H.10    Nakayama, Y.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.