메뉴 건너뛰기




Volumn 4, Issue 6, 2009, Pages 345-350

Tactile mapping system: A novel imaging technology for surface topography and elasticity of tissues or organs

Author keywords

Elasticity image; Extracellular matrix; Resolution; Tactile mapping system; Vascular tissue

Indexed keywords

SODIUM CHLORIDE;

EID: 74249109947     PISSN: 15569845     EISSN: 15590879     Source Type: Journal    
DOI: 10.1097/IMI.0b013e3181c45bf9     Document Type: Article
Times cited : (4)

References (22)
  • 1
    • 48749100202 scopus 로고    scopus 로고
    • Imaging aspects of cardiovascular disease at the cell and molecular level
    • Taatjes DJ, Wadsworth MP, Quinn AS, et al. Imaging aspects of cardiovascular disease at the cell and molecular level. Histochem Cell Biol. 2008;130:235-245.
    • (2008) Histochem Cell Biol , vol.130 , pp. 235-245
    • Taatjes, D.J.1    Wadsworth, M.P.2    Quinn, A.S.3
  • 2
    • 14944380678 scopus 로고    scopus 로고
    • Imaging coronary artery microstructure using second-harmonic and two-photon fluorescence microscopy
    • Zoumi A, Lu X, Kassab GS, Tromberg BJ. Imaging coronary artery microstructure using second-harmonic and two-photon fluorescence microscopy. Biophys J. 2004;87:2778-2786.
    • (2004) Biophys J , vol.87 , pp. 2778-2786
    • Zoumi, A.1    Lu, X.2    Kassab, G.S.3    Tromberg, B.J.4
  • 4
    • 2342608476 scopus 로고    scopus 로고
    • Force and compliance measurements on living cells using atomic force microscopy 1 (AFM)
    • Wojcikiewicz EP, Zhang X, Moy VT. Force and compliance measurements on living cells using atomic force microscopy 1 (AFM). Biol Proced Online. 2003;6:1-9.
    • (2003) Biol Proced Online , vol.6 , pp. 1-9
    • Wojcikiewicz, E.P.1    Zhang, X.2    Moy, V.T.3
  • 5
    • 11244266995 scopus 로고    scopus 로고
    • Micromechanical architecture of the endothelial cell cortex
    • Pesen D, Hoh JH. Micromechanical architecture of the endothelial cell cortex. Biophys J. 2005;88:670-679.
    • (2005) Biophys J , vol.88 , pp. 670-679
    • Pesen, D.1    Hoh, J.H.2
  • 6
    • 4544250739 scopus 로고    scopus 로고
    • Surface probe measurements of the elasticity of sectioned tissue, thin gels and polyelectrolyte multilayer films: Correlations between substrate stiffness and cell adhesion
    • Engler AJ, Richert L, Wong JY, et al. Surface probe measurements of the elasticity of sectioned tissue, thin gels and polyelectrolyte multilayer films: correlations between substrate stiffness and cell adhesion. Surface Sci. 2004;570:142-154.
    • (2004) Surface Sci , vol.570 , pp. 142-154
    • Engler, A.J.1    Richert, L.2    Wong, J.Y.3
  • 7
    • 33847771071 scopus 로고    scopus 로고
    • The stiffness of collagen fibrils influences vascular smooth muscle cell phenotype
    • McDaniel DP, Shaw GA, Elliott JT, et al. The stiffness of collagen fibrils influences vascular smooth muscle cell phenotype. Biophys J. 2007;92: 1759-1769.
    • (2007) Biophys J , vol.92 , pp. 1759-1769
    • McDaniel, D.P.1    Shaw, G.A.2    Elliott, J.T.3
  • 9
    • 2142765353 scopus 로고    scopus 로고
    • Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy
    • Stolz M, Raiteri R, Daniels AU, et al. Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. Biophys J. 2004;86:3269-3283.
    • (2004) Biophys J , vol.86 , pp. 3269-3283
    • Stolz, M.1    Raiteri, R.2    Daniels, A.U.3
  • 10
    • 17644381242 scopus 로고    scopus 로고
    • Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology
    • Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sensor Actuat A. 2005;120:543-549.
    • (2005) Sensor Actuat A , vol.120 , pp. 543-549
    • Murayama, Y.1    Constantinou, C.E.2    Omata, S.3
  • 11
    • 0942299400 scopus 로고    scopus 로고
    • Fabrication of micro-tactile sensor for the measurement of micro-scale local elasticity
    • Murayama Y, Omata S. Fabrication of micro-tactile sensor for the measurement of micro-scale local elasticity. Sensor Actuat A. 2004;109: 202-207.
    • (2004) Sensor Actuat A , vol.109 , pp. 202-207
    • Murayama, Y.1    Omata, S.2
  • 12
    • 63549092341 scopus 로고    scopus 로고
    • Local elasticity imaging of vascular tissues by tactile mapping system
    • Oie T, Murayama Y, Fukuda T, et al. Local elasticity imaging of vascular tissues by tactile mapping system. J Artif Organs. 2009;12:40-46.
    • (2009) J Artif Organs , vol.12 , pp. 40-46
    • Oie, T.1    Murayama, Y.2    Fukuda, T.3
  • 13
    • 0346996699 scopus 로고    scopus 로고
    • Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement
    • Murayama Y, Omata S, Constantinou CE. Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67-72.
    • (2004) J Biomech , vol.37 , pp. 67-72
    • Murayama, Y.1    Omata, S.2    Constantinou, C.E.3
  • 14
    • 0033990271 scopus 로고    scopus 로고
    • A newly designed tensile tester for cells and its application to fibroblasts
    • Miyazaki H, Hasegawa Y, Hayashi K. A newly designed tensile tester for cells and its application to fibroblasts. J Biomech. 2000;33:97-104.
    • (2000) J Biomech , vol.33 , pp. 97-104
    • Miyazaki, H.1    Hasegawa, Y.2    Hayashi, K.3
  • 15
    • 0033935317 scopus 로고    scopus 로고
    • Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve 1 for hepatectomy
    • Kusaka K, Harihara Y, Torzilli, et al. Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve 1 for hepatectomy. J Am Coll Surg. 2000;1:47-53.
    • (2000) J Am Coll Surg , vol.1 , pp. 47-53
    • Kusaka, K.1    Torzilli, H.Y.2
  • 16
    • 0042431781 scopus 로고    scopus 로고
    • Tactile sensing technology for minimal access surgery-a review
    • Eltaib ME, Hewit JR. Tactile sensing technology for minimal access surgery-a review. Mechatronics. 2003;13:1163-1177.
    • (2003) Mechatronics , vol.13 , pp. 1163-1177
    • Eltaib, M.E.1    Hewit, J.R.2
  • 17
    • 0032788218 scopus 로고    scopus 로고
    • Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate
    • Nakayama Y, Matsuda T. Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate. J Biomed Mater Res. 1999;48:511-521.
    • (1999) J Biomed Mater Res , vol.48 , pp. 511-521
    • Nakayama, Y.1    Matsuda, T.2
  • 18
    • 33947504944 scopus 로고    scopus 로고
    • Development of biotube vascular grafts incorporating cuffs for easy implantation
    • Watanabe T, Kanda K, Ishibashi-Umeda H, et al. Development of biotube vascular grafts incorporating cuffs for easy implantation. J Artif Organs. 2007;10:10-15.
    • (2007) J Artif Organs , vol.10 , pp. 10-15
    • Watanabe, T.1    Kanda, K.2    Ishibashi-Umeda, H.3
  • 19
    • 34648816340 scopus 로고    scopus 로고
    • Development of the wingattached rod for acceleration of "biotube" vascular grafts fabrication in vivo
    • Sakai O, Kanda K, Ishibashi-Ueda H, et al. Development of the wingattached rod for acceleration of "Biotube" vascular grafts fabrication in vivo. J Biomed Mater Res. 2007;83:240-247.
    • (2007) J Biomed Mater Res , vol.83 , pp. 240-247
    • Sakai, O.1    Kanda, K.2    Ishibashi-Ueda, H.3
  • 20
    • 34250785137 scopus 로고    scopus 로고
    • Development of an in vivo tissue-engineered autologous heart valve (the Biovalve): Preparation of prototype model
    • Hayashida K, Kanda K, Yaku H, et al. Development of an in vivo tissue-engineered autologous heart valve (the Biovalve): preparation of prototype model. J Thorac Cardiovasc Surg. 2007;134:152-159.
    • (2007) J Thorac Cardiovasc Surg , vol.134 , pp. 152-159
    • Hayashida, K.1    Kanda, K.2    Yaku, H.3
  • 22
    • 34948849851 scopus 로고    scopus 로고
    • Tissue-engineered blood vessel for adult arterial revascularization
    • L'Heureux N, McAllister TN, de la Fuente LM. Tissue-engineered blood vessel for adult arterial revascularization. N Engl J Med. 2007;357: 1451-1453.
    • (2007) N Engl J Med , vol.357 , pp. 1451-1453
    • L'Heureux, N.1    McAllister, T.N.2    De La Fuente, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.