메뉴 건너뛰기




Volumn 117, Issue 9, 2010, Pages 1750-1754

Evaluation of axial length measurement of the eye using partial coherence interferometry and ultrasound in cases of macular disease

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; AGED; ARTICLE; CATARACT EXTRACTION; CENTRAL RETINAL THICKNESS; ECHOOCULOGRAPHY; EPIRETINAL MEMBRANE; EYE AXIS LENGTH; FEMALE; HUMAN; INTERFEROMETRY; LENS IMPLANT; MAJOR CLINICAL STUDY; MALE; OPTICAL COHERENCE TOMOGRAPHY; PARTIAL COHERENCE INTERFEROMETRY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; REFRACTION ERROR; RETINA MACULA EDEMA; RETINA MACULA HOLE; RETINA MACULOPATHY; RETROSPECTIVE STUDY; VISUAL SYSTEM PARAMETERS; VITRECTOMY;

EID: 77956340175     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2010.01.018     Document Type: Article
Times cited : (30)

References (11)
  • 1
    • 33745014147 scopus 로고    scopus 로고
    • Surgical results of combined pars plana vitrectomy, phacoemulsification, and intraocular lens implantation
    • Y. Mochizuki, T. Kubota, and Y. Hata Surgical results of combined pars plana vitrectomy, phacoemulsification, and intraocular lens implantation Eur J Ophthalmol 16 2006 279 286
    • (2006) Eur J Ophthalmol , vol.16 , pp. 279-286
    • Mochizuki, Y.1    Kubota, T.2    Hata, Y.3
  • 2
    • 2342657885 scopus 로고    scopus 로고
    • Foldable versus rigid intraocular lenses in conjunction with pars plana vitrectomy and other vitreoretinal procedures
    • L. Al-Attar, W.E. Smiddy, and J.C. Schiffman Foldable versus rigid intraocular lenses in conjunction with pars plana vitrectomy and other vitreoretinal procedures J Cataract Refract Surg 30 2004 1092 1097
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1092-1097
    • Al-Attar, L.1    Smiddy, W.E.2    Schiffman, J.C.3
  • 3
    • 0037373676 scopus 로고    scopus 로고
    • Combined phacoemulsification, intraocular lens implantation, and vitrectomy for eyes with coexisting cataract and vitreoretinal pathology
    • A.M. Demetriades, J.D. Gottsch, and R. Thomsen Combined phacoemulsification, intraocular lens implantation, and vitrectomy for eyes with coexisting cataract and vitreoretinal pathology Am J Ophthalmol 135 2003 291 296
    • (2003) Am J Ophthalmol , vol.135 , pp. 291-296
    • Demetriades, A.M.1    Gottsch, J.D.2    Thomsen, R.3
  • 4
    • 1642482604 scopus 로고    scopus 로고
    • Combined pars plana vitrectomy and lens management in complex vitreoretinal disease
    • N.A. Chaudhry, K.A. Cohen, H.W. Flynn Jr, and T.G. Murray Combined pars plana vitrectomy and lens management in complex vitreoretinal disease Semin Ophthalmol 18 2003 132 141
    • (2003) Semin Ophthalmol , vol.18 , pp. 132-141
    • Chaudhry, N.A.1    Cohen, K.A.2    Flynn, Jr.H.W.3    Murray, T.G.4
  • 5
    • 0037974445 scopus 로고    scopus 로고
    • Combined phacoemulsification and pars plana vitrectomy: Clear corneal versus scleral incisions: Prospective randomized multicenter study
    • A. Heiligenhaus, A. Holtkamp, and J. Koch Combined phacoemulsification and pars plana vitrectomy: clear corneal versus scleral incisions: prospective randomized multicenter study J Cataract Refract Surg 29 2003 1106 1112
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1106-1112
    • Heiligenhaus, A.1    Holtkamp, A.2    Koch, J.3
  • 7
    • 0034747904 scopus 로고    scopus 로고
    • The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster
    • A.K. Lam, R. Chan, and P.C. Pang The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster Ophthalmic Physiol Opt 21 2001 477 483
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 477-483
    • Lam, A.K.1    Chan, R.2    Pang, P.C.3
  • 9
    • 33846440521 scopus 로고    scopus 로고
    • Intraocular lens power calculation for combined cataract surgery, vitrectomy and peeling of epiretinal membranes for macular oedema
    • I. Kovacs, M. Ferencz, and J. Nemes Intraocular lens power calculation for combined cataract surgery, vitrectomy and peeling of epiretinal membranes for macular oedema Acta Ophthalmol Scand 85 2007 88 91
    • (2007) Acta Ophthalmol Scand , vol.85 , pp. 88-91
    • Kovacs, I.1    Ferencz, M.2    Nemes, J.3
  • 10
    • 33645770500 scopus 로고    scopus 로고
    • Relationship between the retinal thickness of the macula and the difference in axial length
    • T. Ueda, Y. Nawa, and Y. Hara Relationship between the retinal thickness of the macula and the difference in axial length Graefes Arch Clin Exp Ophthalmol 244 2006 498 501
    • (2006) Graefes Arch Clin Exp Ophthalmol , vol.244 , pp. 498-501
    • Ueda, T.1    Nawa, Y.2    Hara, Y.3
  • 11
    • 34547190129 scopus 로고    scopus 로고
    • Axial length measurement in eyes with diabetic macular edema: A-scan ultrasound versus IOLMaster
    • L. Attas-Fox, D. Zadok, and Y. Gerber Axial length measurement in eyes with diabetic macular edema: a-scan ultrasound versus IOLMaster Ophthalmology 114 2007 1499 1504
    • (2007) Ophthalmology , vol.114 , pp. 1499-1504
    • Attas-Fox, L.1    Zadok, D.2    Gerber, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.