Relationship between the retinal thickness of the macula and the difference in axial length

Author keywords

Cataract surgery; IOLMaster; Optical biometry; Retinal thickness; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; AUDITORY RESPONSE; CATARACT EXTRACTION; CLINICAL ARTICLE; CORNEA REFLEX; CORRELATION COEFFICIENT; CORRELATIONAL STUDY; ECHOOCULOGRAPHY; EYE AXIS LENGTH; HUMAN; INTERMETHOD COMPARISON; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; REFRACTION ERROR; RETINA MACULA EDEMA; RETINA MACULA LUTEA; STATISTICAL SIGNIFICANCE; WILCOXON SIGNED RANKS TEST;

EID: 33645770500     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-005-1146-5     Document Type: Article
Times cited : (16)

References (10)
  • 1
    • 0042206359 scopus 로고    scopus 로고
    • IOLMaster biometry: Refractive results of 100 consecutive cases
    • Eleftheriadis H (2003) IOLMaster biometry: Refractive results of 100 consecutive cases. Br J Ophthalmol 87:960-963
    • (2003) Br J Ophthalmol , vol.87 , pp. 960-963
    • Eleftheriadis, H.1
  • 2
    • 0043173718 scopus 로고    scopus 로고
    • Comparison of laser interferometry and ultrasound A-scan in the measurements of axial length
    • Goyal R, North RV, Morgan JE (2003) Comparison of laser interferometry and ultrasound A-scan in the measurements of axial length. Acta Ophthalmol Scand 81:331-335
    • (2003) Acta Ophthalmol Scand , vol.81 , pp. 331-335
    • Goyal, R.1    North, R.V.2    Morgan, J.E.3
  • 3
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser doppler interferometry
    • Hitzenberger CK (1991) Optical measurement of the axial eye length by laser doppler interferometry. Investig Ophthalmol Vis Sci 32:616-624
    • (1991) Investig Ophthalmol Vis Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 6
    • 1142299597 scopus 로고    scopus 로고
    • Laser interference biometry versus ultrasound biometry in certain clinical conditions
    • Lege BAM, Haigis W (2004) Laser interference biometry versus ultrasound biometry in certain clinical conditions. Graefe's Arch Clin Exp Ophthalmol 242:8-12
    • (2004) Graefe's Arch Clin Exp Ophthalmol , vol.242 , pp. 8-12
    • Lege, B.A.M.1    Haigis, W.2
  • 7
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T (1992) Sources of error in intraocular lens power calculation. J Cataract Refract Surg 18:125-129
    • (1992) J Cataract Refract Surg , vol.18 , pp. 125-129
    • Olsen, T.1
  • 8
    • 0029795914 scopus 로고    scopus 로고
    • Validation of laser Doppler interferometric measurements in vivo of axial eye length and thickness of fundus layers in chicks
    • Schmid GF, Papastergiou GI, Nickla DL, Riva CE, Lin T, Stone RA, Laties AM (1996) Validation of laser Doppler interferometric measurements in vivo of axial eye length and thickness of fundus layers in chicks. Curr Eye Res 15:691-696
    • (1996) Curr Eye Res , vol.15 , pp. 691-696
    • Schmid, G.F.1    Papastergiou, G.I.2    Nickla, D.L.3    Riva, C.E.4    Lin, T.5    Stone, R.A.6    Laties, A.M.7
  • 9
    • 0742305077 scopus 로고    scopus 로고
    • Ocular component measurement using the Zeiss IOLMaster
    • Sheng H, Bottler CA, Bullimore MA (2004) Ocular component measurement using the Zeiss IOLMaster. Optom Vis Sci 81:27-34
    • (2004) Optom Vis Sci , vol.81 , pp. 27-34
    • Sheng, H.1    Bottler, C.A.2    Bullimore, M.A.3
  • 10
    • 0035205647 scopus 로고    scopus 로고
    • Reproducibility of optical biometry using partial coherence interferometry intraobserver and interobserver reliability
    • Vogel A, Dick HB, Krummenauer F (2001) Reproducibility of optical biometry using partial coherence interferometry intraobserver and interobserver reliability. J Cataract Refract Surg 27:1961-1968
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1961-1968
    • Vogel, A.1    Dick, H.B.2    Krummenauer, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.