메뉴 건너뛰기




Volumn 138, Issue 3, 2010, Pages 264-276

Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BONE REGENERATION; CEPHALOMETRY; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; DENTAL ACID ETCHING; DENTAL ETCHING; FEMALE; HUMAN; INSTRUMENTATION; MALE; MALOCCLUSION; MAXILLA; MAXILLARY SINUS; METHODOLOGY; MOLAR TOOTH; ORTHODONTICS; PANORAMIC RADIOGRAPHY; PHYSIOLOGY; PREMOLAR TOOTH; RADIOGRAPHY; RISK FACTOR; SURFACE PROPERTY; THREE DIMENSIONAL IMAGING; TOOTH IMPLANTATION; TOOTH ROOT; DEVICES; MALOCCLUSION, ANGLE CLASS I; MALOCCLUSION, ANGLE CLASS II; PROCEDURES; SURGERY; TOOTH IMPLANT;

EID: 77956333709     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2008.07.026     Document Type: Article
Times cited : (66)

References (35)
  • 1
    • 33644639434 scopus 로고    scopus 로고
    • ''Safe zones'': A guide for miniscrew positioning in the maxillary and mandibular arch
    • P.M. Poggio, C. Incorvati, S. Velo, and A. Carano ''Safe zones'': a guide for miniscrew positioning in the maxillary and mandibular arch Angle Orthod 76 2006 191 197
    • (2006) Angle Orthod , vol.76 , pp. 191-197
    • Poggio, P.M.1    Incorvati, C.2    Velo, S.3    Carano, A.4
  • 2
    • 4444301021 scopus 로고    scopus 로고
    • An anatomical study using CT image for the implantation of micro-implants
    • H.S. Park An anatomical study using CT image for the implantation of micro-implants Korea J Orthod 32 2002 435 441
    • (2002) Korea J Orthod , vol.32 , pp. 435-441
    • Park, H.S.1
  • 3
    • 38349009101 scopus 로고    scopus 로고
    • Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region
    • C.H. Moon, D.G. Lee, H.S. Lee, J.S. Im, and S.H. Baek Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region Angle Orthod 78 2008 101 106
    • (2008) Angle Orthod , vol.78 , pp. 101-106
    • Moon, C.H.1    Lee, D.G.2    Lee, H.S.3    Im, J.S.4    Baek, S.H.5
  • 5
    • 65249097776 scopus 로고    scopus 로고
    • Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography
    • S.H. Kim, H.G. Yoon, Y.S. Choi, E.H. Hwang, Y.A. Kook, and G. Nelson Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography Am J Orthod Dentofacial Orthop 135 2009 635 641
    • (2009) Am J Orthod Dentofacial Orthop , vol.135 , pp. 635-641
    • Kim, S.H.1    Yoon, H.G.2    Choi, Y.S.3    Hwang, E.H.4    Kook, Y.A.5    Nelson, G.6
  • 7
    • 34548567237 scopus 로고    scopus 로고
    • A precise wire guide for positioning interradicular miniscrews
    • H.J. Choi, T.W. Kim, and H.W. Kim A precise wire guide for positioning interradicular miniscrews J Clin Orthod 41 2007 258 261
    • (2007) J Clin Orthod , vol.41 , pp. 258-261
    • Choi, H.J.1    Kim, T.W.2    Kim, H.W.3
  • 8
    • 33644694854 scopus 로고    scopus 로고
    • An adjustable surgical guide for miniscrew placement
    • E.Y. Suzuki, and B. Buranastidporn An adjustable surgical guide for miniscrew placement J Clin Orthod 39 2005 588 590
    • (2005) J Clin Orthod , vol.39 , pp. 588-590
    • Suzuki, E.Y.1    Buranastidporn, B.2
  • 10
    • 34247137843 scopus 로고    scopus 로고
    • Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography
    • S.H. Kim, Y.S. Choi, E.H. Hwang, K.R. Chung, Y.A. Kook, and G. Nelson Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography Am J Orthod Dentofacial Orthop 131 Suppl 2007 S82 S89
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , Issue.SUPPL.
    • Kim, S.H.1    Choi, Y.S.2    Hwang, E.H.3    Chung, K.R.4    Kook, Y.A.5    Nelson, G.6
  • 12
    • 3843123180 scopus 로고    scopus 로고
    • Dental CT and orthodontic implants: Imaging technique and assessment of available bone volume in the hard palate
    • A. Gahleitner, B. Podesser, S. Schick, G. Watzek, and H. Imhof Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate Eur J Radiol 51 2004 257 262
    • (2004) Eur J Radiol , vol.51 , pp. 257-262
    • Gahleitner, A.1    Podesser, B.2    Schick, S.3    Watzek, G.4    Imhof, H.5
  • 13
  • 16
    • 32644476336 scopus 로고    scopus 로고
    • Clinical study on success rate on microscrew implants for orthodontic anchorage
    • H.S. Park Clinical study on success rate on microscrew implants for orthodontic anchorage Korea J Orthod 33 2003 151 156
    • (2003) Korea J Orthod , vol.33 , pp. 151-156
    • Park, H.S.1
  • 17
    • 33745835122 scopus 로고    scopus 로고
    • Factors affecting the clinical success of screw implants used as orthodontic anchorage
    • H.S. Park, S.H. Jeong, and O.W. Kwon Factors affecting the clinical success of screw implants used as orthodontic anchorage Am J Orthod Dentofacial Orthop 130 2006 18 24
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 18-24
    • Park, H.S.1    Jeong, S.H.2    Kwon, O.W.3
  • 20
    • 38349001355 scopus 로고    scopus 로고
    • Influence of surface characteristics on survival rates of mini-implants
    • K. Chaddad, A.F.H. Ferreira, N. Geurs, and M.S. Reddy Influence of surface characteristics on survival rates of mini-implants Angle Orthod 78 2008 107 113
    • (2008) Angle Orthod , vol.78 , pp. 107-113
    • Chaddad, K.1    Ferreira, A.F.H.2    Geurs, N.3    Reddy, M.S.4
  • 22
    • 3042598772 scopus 로고    scopus 로고
    • Do miniscrews remain stationary under orthodontic forces?
    • E.J. Liou, B.C. Pai, and J.C. Lin Do miniscrews remain stationary under orthodontic forces? Am J Orthod Dentofacial Orthop 126 2004 42 47
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 42-47
    • Liou, E.J.1    Pai, B.C.2    Lin, J.C.3
  • 23
    • 34447098273 scopus 로고    scopus 로고
    • Severe bidentoalveolar protrusion treated with orthodontic microimplant-dependent en-masse retraction
    • K.R. Chung, G. Nelson, S.H. Kim, and Y.A. Kook Severe bidentoalveolar protrusion treated with orthodontic microimplant-dependent en-masse retraction Am J Orthod Dentofacial Orthop 132 2007 105 115
    • (2007) Am J Orthod Dentofacial Orthop , vol.132 , pp. 105-115
    • Chung, K.R.1    Nelson, G.2    Kim, S.H.3    Kook, Y.A.4
  • 24
    • 67949112899 scopus 로고    scopus 로고
    • Analysis of temporary skeletal anchorage devices used for en-masse retraction: A preliminary study
    • S.H. Kim, Y.S. Hwang, A. Ferreira, and K.R. Chung Analysis of temporary skeletal anchorage devices used for en-masse retraction: a preliminary study Am J Orthod Dentofacial Orthop 136 2009 268 276
    • (2009) Am J Orthod Dentofacial Orthop , vol.136 , pp. 268-276
    • Kim, S.H.1    Hwang, Y.S.2    Ferreira, A.3    Chung, K.R.4
  • 25
    • 46249091720 scopus 로고    scopus 로고
    • Study on removal torque of SLA (sandblasted, large grit and acid etched) treated microimplant
    • N.H. Oh, S.H. Kim, Y.A. Kook, and S.S. Mo Study on removal torque of SLA (sandblasted, large grit and acid etched) treated microimplant Korean J Orthod 36 2006 324 330
    • (2006) Korean J Orthod , vol.36 , pp. 324-330
    • Oh, N.H.1    Kim, S.H.2    Kook, Y.A.3    Mo, S.S.4
  • 26
    • 67949121476 scopus 로고    scopus 로고
    • The comparison of removal torque values and SEM findings of orthodontic C-implant before and after recycling procedure
    • T.S. Ko, Y.J. Ji, S.H. Kim, Y.A. Kook, H.G. Gong, and H.C. Song The comparison of removal torque values and SEM findings of orthodontic C-implant before and after recycling procedure J Korean Assoc Hosp Dent 2 2006 88 95
    • (2006) J Korean Assoc Hosp Dent , vol.2 , pp. 88-95
    • Ko, T.S.1    Ji, Y.J.2    Kim, S.H.3    Kook, Y.A.4    Gong, H.G.5    Song, H.C.6
  • 27
    • 84875810264 scopus 로고    scopus 로고
    • A pilot study of the osseointegration potential of a surface-treated mini-implant: Bone contact of implants retrieved from patients
    • W.K. Seo, S.H. Kim, K.R. Chung, and G. Nelson A pilot study of the osseointegration potential of a surface-treated mini-implant: bone contact of implants retrieved from patients World J Orthod 10 2009 202 210
    • (2009) World J Orthod , vol.10 , pp. 202-210
    • Seo, W.K.1    Kim, S.H.2    Chung, K.R.3    Nelson, G.4
  • 28
    • 52449092888 scopus 로고    scopus 로고
    • Anterior torque control using partial-osseointegration mini-implants: Biocreative therapy type i technique
    • K.R. Chung, S.H. Kim, Y.A. Kook, and J.H. Son Anterior torque control using partial-osseointegration mini-implants: biocreative therapy type I technique World J Orthod 9 2008 95 104
    • (2008) World J Orthod , vol.9 , pp. 95-104
    • Chung, K.R.1    Kim, S.H.2    Kook, Y.A.3    Son, J.H.4
  • 29
    • 52449092883 scopus 로고    scopus 로고
    • Anterior torque control using partial-osseointegration mini-implants: Biocreative therapy type II technique
    • K.R. Chung, S.H. Kim, Y.A. Kook, and H. Choo Anterior torque control using partial-osseointegration mini-implants: biocreative therapy type II technique World J Orthod 9 2008 105 113
    • (2008) World J Orthod , vol.9 , pp. 105-113
    • Chung, K.R.1    Kim, S.H.2    Kook, Y.A.3    Choo, H.4
  • 30
    • 21344445511 scopus 로고    scopus 로고
    • Early wound healing around endosseous implants: A review of the literature
    • S. Raghavendra, M.C. Wood, and T.D. Taylor Early wound healing around endosseous implants: a review of the literature Int J Oral Maxillofac Implants 20 2005 425 431
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 425-431
    • Raghavendra, S.1    Wood, M.C.2    Taylor, T.D.3
  • 31
    • 0019553907 scopus 로고
    • Repair processes in the cervical region of replanted and transplanted teeth in monkeys
    • J.O. Andreasen, and L. Kristerson Repair processes in the cervical region of replanted and transplanted teeth in monkeys Int J Oral Surg 10 1981 128 136
    • (1981) Int J Oral Surg , vol.10 , pp. 128-136
    • Andreasen, J.O.1    Kristerson, L.2
  • 32
    • 3242689084 scopus 로고    scopus 로고
    • Mechanism of osseointegration: Characterization of supporting bone with indentation testing and backscattered imaging
    • S.S. Huja, and E. Roberts Mechanism of osseointegration: characterization of supporting bone with indentation testing and backscattered imaging Semin Orthod 10 2004 162 173
    • (2004) Semin Orthod , vol.10 , pp. 162-173
    • Huja, S.S.1    Roberts, E.2
  • 34
    • 0036651454 scopus 로고    scopus 로고
    • The miniplate with tube for skeletal anchorage
    • K.R. Chung, Y.S. Kim, and Y.J. Lee The miniplate with tube for skeletal anchorage J Clin Orthod 36 2002 407 412
    • (2002) J Clin Orthod , vol.36 , pp. 407-412
    • Chung, K.R.1    Kim, Y.S.2    Lee, Y.J.3
  • 35
    • 37449025849 scopus 로고    scopus 로고
    • Class II malocclusion corrected with a lingual retractor combined with a palatal plate
    • K.R. Chung, Y.A. Kook, S.H. Kim, S.S. Mo, and J.A. Jung Class II malocclusion corrected with a lingual retractor combined with a palatal plate Am J Orthod Dentofacial Orthop 133 2008 112 123
    • (2008) Am J Orthod Dentofacial Orthop , vol.133 , pp. 112-123
    • Chung, K.R.1    Kook, Y.A.2    Kim, S.H.3    Mo, S.S.4    Jung, J.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.