메뉴 건너뛰기




Volumn , Issue , 2010, Pages 1049-1052

Experimental validation and sensitivity analysis for CFD simulations of cerebral aneurysms

Author keywords

Aneurysm; CFD simulation; Sensitivity analysis; Time intensity curve; Validation; Virtual angiography

Indexed keywords

ANEURYSM; CEREBRAL ANEURYSMS; CFD SIMULATIONS; COMPUTATIONAL FLUID DYNAMICS SIMULATIONS; CONTROLLED CONDITIONS; EXPERIMENTAL DATA; EXPERIMENTAL VALIDATIONS; MEASURING TECHNIQUE; PARAMETRIC STUDY; PATIENT CASE; QUANTITATIVE MEASURES; VIRTUAL ANGIOGRAPHY;

EID: 77955218176     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2010.5490170     Document Type: Conference Paper
Times cited : (4)

References (11)
  • 1
    • 29144522244 scopus 로고    scopus 로고
    • Virtual angiography for visualization and validation of computational fluid dynamics models of aneurysm hemodynamics
    • M.D. Ford et al., "Virtual angiography for visualization and validation of computational fluid dynamics models of aneurysm hemodynamics", IEEE Trans. Med. Imag. 24(12), pp. 1586-1592, 2005.
    • (2005) IEEE Trans. Med. Imag. , vol.24 , Issue.12 , pp. 1586-1592
    • Ford, M.D.1
  • 2
    • 34250197872 scopus 로고    scopus 로고
    • Computational fluid dynamics modeling of intracranial aneurysms: Qualitative comparison with cerebral angiography
    • J. Cebral et al., "Computational fluid dynamics modeling of intracranial aneurysms: Qualitative comparison with cerebral angiography", Academic Radiology, 14(7), pp. 804-813, 2007.
    • (2007) Academic Radiology , vol.14 , Issue.7 , pp. 804-813
    • Cebral, J.1
  • 3
    • 51049088598 scopus 로고    scopus 로고
    • Toward quantitative virtual angiography: Evaluation with in vitro studies
    • J. Durant et al., "Toward quantitative virtual angiography: evaluation with in vitro studies", 5th IEEE International Symposium on Biomedical Imaging, pp. 632-635, 2008.
    • (2008) 5th IEEE International Symposium on Biomedical Imaging , pp. 632-635
    • Durant, J.1
  • 4
    • 70449334329 scopus 로고    scopus 로고
    • Quantitative evaluation of virtual angiography for interventional X-ray acquisitions
    • Q. Sun et al., "Quantitative evaluation of virtual angiography for interventional X-ray acquisitions", IEEE International Symposium on Biomedical Imaging, pp. 895-898, 2009.
    • (2009) IEEE International Symposium on Biomedical Imaging , pp. 895-898
    • Sun, Q.1
  • 5
    • 33846412594 scopus 로고    scopus 로고
    • Validation of CFD simulations of cerebral aneurysms with implication of geometric variations
    • Y. Hoi et al., "Validation of CFD simulations of cerebral aneurysms with implication of geometric variations", Trans. of ASME, 128, pp. 844-851, 2006.
    • (2006) Trans. of ASME , vol.128 , pp. 844-851
    • Hoi, Y.1
  • 6
    • 34447320750 scopus 로고    scopus 로고
    • Flow in simplified and real models of intracranial aneurysms
    • G. Paál et al., "Flow in simplified and real models of intracranial aneurysms", International Journal of Heat and Fluid Flow 28, pp. 653-664, 2007.
    • (2007) International Journal of Heat and Fluid Flow , vol.28 , pp. 653-664
    • Paál, G.1
  • 7
    • 0029179430 scopus 로고
    • A signal processing approach to fair surface design
    • G. Taubin, "A signal processing approach to fair surface design", Proc. of Computer Graphics, pp. 351-358, 1995.
    • (1995) Proc. of Computer Graphics , pp. 351-358
    • Taubin, G.1
  • 8
    • 17444424630 scopus 로고    scopus 로고
    • Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity
    • J.R. Cebral et al., "Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity", IEEE Trans. Med. Imag., 24(4), pp. 457-467, 2005.
    • (2005) IEEE Trans. Med. Imag. , vol.24 , Issue.4 , pp. 457-467
    • Cebral, J.R.1
  • 9
    • 0037393677 scopus 로고    scopus 로고
    • Image-based computational simulation of flow dynamics in a giant intracranial aneurysm
    • D.A. Steinmann et al., "Image-based computational simulation of flow dynamics in a giant intracranial aneurysm", AJNR Am J Neuroradiol 24(4): pp. 556-566, 2003.
    • (2003) AJNR Am J Neuroradiol , vol.24 , Issue.4 , pp. 556-566
    • Steinmann, D.A.1
  • 10
    • 33845613667 scopus 로고    scopus 로고
    • The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: A CFD model compared to in vivo ultrasound measurement
    • N.M. Maurits et al., "The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: A CFD model compared to in vivo ultrasound measurement", Journal of Biomechanics 40, pp. 427-436, 2007.
    • (2007) Journal of Biomechanics , vol.40 , pp. 427-436
    • Maurits, N.M.1
  • 11
    • 0034778642 scopus 로고    scopus 로고
    • Importance of angle correction in measurement of blood flow velocity with transcranial doppler sonography
    • J. Krejza et al., "Importance of angle correction in measurement of blood flow velocity with transcranial doppler sonography", AJ R Am J Neuroradiol 22, pp. 1743-1747, 2001.
    • (2001) AJ R Am J Neuroradiol , vol.22 , pp. 1743-1747
    • Krejza, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.