메뉴 건너뛰기




Volumn 32, Issue 3, 2010, Pages 654-662

Post-processing correction of the endorectal coil reception effects in MR spectroscopic imaging of the prostate

Author keywords

Correction; Endorectal coil; Magnetic resonance spectroscopic imaging; Prostate; Reception profile

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; CLINICAL ARTICLE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; PROSTATE CANCER;

EID: 77956301805     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22258     Document Type: Article
Times cited : (18)

References (30)
  • 1
    • 46049104223 scopus 로고    scopus 로고
    • American Cancer Society. Atlanta: American Cancer Society
    • American Cancer Society. Cancer Facts & Figures 2008. Atlanta: American Cancer Society; 2008.
    • (2008) Cancer Facts & Figures 2008
  • 2
    • 36949010950 scopus 로고    scopus 로고
    • Current status of intensity-modulated radiation therapy (IMRT)
    • Hatano K, Araki H, Sakai M, et al. Current status of intensity-modulated radiation therapy (IMRT). Int J Clin Oncol 2007;12:408-415.
    • (2007) Int J Clin Oncol , vol.12 , pp. 408-415
    • Hatano, K.1    Araki, H.2    Sakai, M.3
  • 3
    • 0028113557 scopus 로고
    • Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal - Pelvic phased-array coils
    • Hricak H, White S, Vigneron D, et al. Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal - pelvic phased-array coils. Radiology 1994;193:703-709.
    • (1994) Radiology , vol.193 , pp. 703-709
    • Hricak, H.1    White, S.2    Vigneron, D.3
  • 4
    • 0030056928 scopus 로고    scopus 로고
    • Three-dimensional H-1 MR spectroscopic imaging of the in situ human prostate with high (0.24-0.7-cm3) spatial resolution
    • Kurhanewicz J, Vigneron DB, Hricak H, Narayan P, Carroll P, Nelson SJ. Three-dimensional H-1 MR spectroscopic imaging of the in situ human prostate with high (0.24-0.7-cm3) spatial resolution. Radiology 1996;198:795-805.
    • (1996) Radiology , vol.198 , pp. 795-805
    • Kurhanewicz, J.1    Vigneron, D.B.2    Hricak, H.3    Narayan, P.4    Carroll, P.5    Nelson, S.J.6
  • 5
    • 0034087595 scopus 로고    scopus 로고
    • Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer
    • Kurhanewicz J, Vigneron DB, Nelson SJ. Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer. Neoplasia 2000;2:166-189.
    • (2000) Neoplasia , vol.2 , pp. 166-189
    • Kurhanewicz, J.1    Vigneron, D.B.2    Nelson, S.J.3
  • 6
    • 0029930459 scopus 로고    scopus 로고
    • Hormonal ablation of prostatic cancer: Effects on prostate morphology, tumor detection, and staging by endorectal coil MR imaging
    • Chen M, Hricak H, Kalbhen CL, et al. Hormonal ablation of prostatic cancer: effects on prostate morphology, tumor detection, and staging by endorectal coil MR imaging. AJR Am J Roentgenol 1996;166:1157-1163.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 1157-1163
    • Chen, M.1    Hricak, H.2    Kalbhen, C.L.3
  • 7
    • 0029671181 scopus 로고    scopus 로고
    • Prostate carcinoma: MR imaging findings after cryosurgery
    • Kalbhen CL, Hricak H, Shinohara K, et al. Prostate carcinoma: MR imaging findings after cryosurgery. Radiology 1996;198:807-811.
    • (1996) Radiology , vol.198 , pp. 807-811
    • Kalbhen, C.L.1    Hricak, H.2    Shinohara, K.3
  • 8
    • 2942513713 scopus 로고    scopus 로고
    • Endorectal MR imaging and MR spectroscopic imaging for locally recurrent prostate cancer after external beam radiation therapy: Preliminary experience
    • Coakley FV, Teh HS, Qayyum A, et al. Endorectal MR imaging and MR spectroscopic imaging for locally recurrent prostate cancer after external beam radiation therapy: preliminary experience. Radiology 2004;233:441-448.
    • (2004) Radiology , vol.233 , pp. 441-448
    • Coakley, F.V.1    Teh, H.S.2    Qayyum, A.3
  • 9
    • 0027477819 scopus 로고
    • In vitro high resolution 1H-spectroscopy of the human prostate: Benign prostatic hyperplasia, normal peripheral zone and adenocarcinoma
    • Schiebler ML, Miyamoto KK, White M, Maygarden SJ, Mohler JL. In vitro high resolution 1H-spectroscopy of the human prostate: benign prostatic hyperplasia, normal peripheral zone and adenocarcinoma. Magn Reson Med 1993;29:285-291.
    • (1993) Magn Reson Med , vol.29 , pp. 285-291
    • Schiebler, M.L.1    Miyamoto, K.K.2    White, M.3    Maygarden, S.J.4    Mohler, J.L.5
  • 11
    • 0033970816 scopus 로고    scopus 로고
    • Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer
    • Tran TK, Vigneron DB, Sailasuta N, et al. Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer. Magn Reson Med 2000;43:23-33.
    • (2000) Magn Reson Med , vol.43 , pp. 23-33
    • Tran, T.K.1    Vigneron, D.B.2    Sailasuta, N.3
  • 12
    • 18244403532 scopus 로고    scopus 로고
    • Sequence design for magnetic resonance spectroscopic imaging of prostate cancer at 3 T
    • Cunningham CH, Vigneron DB, Marjanska M, et al. Sequence design for magnetic resonance spectroscopic imaging of prostate cancer at 3 T. Magn Reson Med 2005;53:1033-1039.
    • (2005) Magn Reson Med , vol.53 , pp. 1033-1039
    • Cunningham, C.H.1    Vigneron, D.B.2    Marjanska, M.3
  • 13
    • 33746983480 scopus 로고    scopus 로고
    • High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence
    • Chen AP, Cunningham CH, Kurhanewicz J, et al. High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence. Magn Reson Imaging 2006;24:825-832.
    • (2006) Magn Reson Imaging , vol.24 , pp. 825-832
    • Chen, A.P.1    Cunningham, C.H.2    Kurhanewicz, J.3
  • 14
    • 0031422032 scopus 로고    scopus 로고
    • Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses
    • Star-Lack J, Vigneron DB, Pauly J, Kurhanewicz J, Nelson SJ. Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses. J Magn Reson Imaging 1997;7:745-757.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 745-757
    • Star-Lack, J.1    Vigneron, D.B.2    Pauly, J.3    Kurhanewicz, J.4    Nelson, S.J.5
  • 15
    • 45249126523 scopus 로고
    • A new method for automatic quantifcation of 1-D spectra with low signal to noise ratio
    • Nelson S, Brown T. A new method for automatic quantifcation of 1-D spectra with low signal to noise ratio. J Magn Reson Imaging 1987;84:95-109.
    • (1987) J Magn Reson Imaging , vol.84 , pp. 95-109
    • Nelson, S.1    Brown, T.2
  • 16
    • 0034904232 scopus 로고    scopus 로고
    • Analysis of volume MRI and MR spectroscopic imaging data for the evaluation of patients with brain tumors
    • Nelson SJ. Analysis of volume MRI and MR spectroscopic imaging data for the evaluation of patients with brain tumors. Magn Reson Med 2001;46:228-239.
    • (2001) Magn Reson Med , vol.46 , pp. 228-239
    • Nelson, S.J.1
  • 17
    • 0026116321 scopus 로고
    • Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]
    • Pauly J, Le Roux P, Nishimura D, Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. IEEE Trans Med Imaging 1991;10:53-65.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 53-65
    • Pauly, J.1    Le Roux, P.2    Nishimura, D.3    Macovski, A.4
  • 18
    • 0029265843 scopus 로고
    • Surface coil MR imaging of the human brain with an analytical reception profile correction
    • Moyher SE, Vigneron DB, Nelson SJ. Surface coil MR imaging of the human brain with an analytical reception profile correction. J Magn Reson Imaging 1995;5:139-144.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 139-144
    • Moyher, S.E.1    Vigneron, D.B.2    Nelson, S.J.3
  • 19
    • 31844453906 scopus 로고    scopus 로고
    • Expandable and rigid endorectal coils for prostate MRI: Impact on prostate distortion and rigid image registration
    • Kim Y, Noworolski SM, Pouliot J, Hsu IJ, Vigneron DB, Kurhanewicz J. Expandable and rigid endorectal coils for prostate MRI: impact on prostate distortion and rigid image registration. Med Phys 2005;32:3569-3578.
    • (2005) Med Phys , vol.32 , pp. 3569-3578
    • Kim, Y.1    Noworolski, S.M.2    Pouliot, J.3    Hsu, I.J.4    Vigneron, D.B.5    Kurhanewicz, J.6
  • 20
    • 12844274447 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced MRI in normal and abnormal prostate tissues as defined by biopsy, MRI and 3D MRSI
    • Noworolski SM, Henry RG, Vigneron DB, Kurhanewicz J. Dynamic contrast-enhanced MRI in normal and abnormal prostate tissues as defined by biopsy, MRI and 3D MRSI. Magn Reson Med 2005;53:249-255.
    • (2005) Magn Reson Med , vol.53 , pp. 249-255
    • Noworolski, S.M.1    Henry, R.G.2    Vigneron, D.B.3    Kurhanewicz, J.4
  • 21
  • 22
    • 51449117038 scopus 로고    scopus 로고
    • Reproducibility study of whole-brain 1H spectroscopic imaging with automated quantification
    • Gu M, Kim DH, Mayer D, Sullivan EV, Pfefferbaum A, Spielman DM. Reproducibility study of whole-brain 1H spectroscopic imaging with automated quantification. Magn Reson Med 2008;60:542-547.
    • (2008) Magn Reson Med , vol.60 , pp. 542-547
    • Gu, M.1    Kim, D.H.2    Mayer, D.3    Sullivan, E.V.4    Pfefferbaum, A.5    Spielman, D.M.6
  • 23
    • 35948981483 scopus 로고    scopus 로고
    • Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T
    • Li Y, Osorio JA, Ozturk-Isik E, et al. Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T. Magn Reson Imaging 2006;24:1295-1302.
    • (2006) Magn Reson Imaging , vol.24 , pp. 1295-1302
    • Li, Y.1    Osorio, J.A.2    Ozturk-Isik, E.3
  • 24
    • 34547765838 scopus 로고    scopus 로고
    • 3D 1H MRSI of brain tumors at 3.0 Tesla using an eight-channel phased-array head coil
    • Osorio JA, Ozturk-Isik E, Xu D, et al. 3D 1H MRSI of brain tumors at 3.0 Tesla using an eight-channel phased-array head coil. J Magn Reson Imaging 2007;26:23-30.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 23-30
    • Osorio, J.A.1    Ozturk-Isik, E.2    Xu, D.3
  • 26
    • 33646465663 scopus 로고    scopus 로고
    • Unaliasing lipid contamination for MR spectroscopic imaging of gliomas at 3T using sensitivity encoding (SENSE)
    • Ozturk-Isik E, Crane JC, Cha S, Chang SM, Berger MS, Nelson SJ. Unaliasing lipid contamination for MR spectroscopic imaging of gliomas at 3T using sensitivity encoding (SENSE). Magn Reson Med 2006;55:1164-1169.
    • (2006) Magn Reson Med , vol.55 , pp. 1164-1169
    • Ozturk-Isik, E.1    Crane, J.C.2    Cha, S.3    Chang, S.M.4    Berger, M.S.5    Nelson, S.J.6
  • 27
    • 33846783246 scopus 로고    scopus 로고
    • Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in the human brain
    • Lin FH, Tsai SY, Otazo R, et al. Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in the human brain. Magn Reson Med 2007;57:249-57.
    • (2007) Magn Reson Med , vol.57 , pp. 249-257
    • Lin, F.H.1    Tsai, S.Y.2    Otazo, R.3
  • 28
    • 13244249778 scopus 로고    scopus 로고
    • Prostate cancer: Evaluation with endorectal MR imaging and three-dimensional proton MR spectroscopic imaging
    • Torino
    • Casciani E, Polettini E, Bertini L, et al. Prostate cancer: evaluation with endorectal MR imaging and three-dimensional proton MR spectroscopic imaging. Radiol Med (Torino) 2004;108:530-541.
    • (2004) Radiol Med , vol.108 , pp. 530-541
    • Casciani, E.1    Polettini, E.2    Bertini, L.3
  • 29
    • 7044233362 scopus 로고    scopus 로고
    • Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostate
    • Futterer JJ, Scheenen TW, Huisman HJ, et al. Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostate. Invest Radiol 2004;39:671-680.
    • (2004) Invest Radiol , vol.39 , pp. 671-680
    • Futterer, J.J.1    Scheenen, T.W.2    Huisman, H.J.3
  • 30
    • 0032902819 scopus 로고    scopus 로고
    • High spatial resolution 1H-MRSI and segmented MRI of cortical gray matter and subcortical white matter in three regions of the human brain
    • Noworolski SM, Nelson SJ, Henry RG, et al. High spatial resolution 1H-MRSI and segmented MRI of cortical gray matter and subcortical white matter in three regions of the human brain. Magn Reson Med 1999;41:21-29.
    • (1999) Magn Reson Med , vol.41 , pp. 21-29
    • Noworolski, S.M.1    Nelson, S.J.2    Henry, R.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.