메뉴 건너뛰기




Volumn 141, Issue , 2010, Pages 20S-24S

Integrating Three-Dimensional Digital Technologies for Comprehensive Implant Dentistry

(1)  Patel, Neal a  

a NONE   (United States)

Author keywords

CAD CAM; cone beam computed tomography; fixed prosthetics; guided implant surgery; implants; restorative dentistry

Indexed keywords

ARTICLE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED SURGERY; CONE BEAM COMPUTED TOMOGRAPHY; DENTAL IMPRESSION; DENTURE; EDENTULOUSNESS; HUMAN; METHODOLOGY; RADIOGRAPHY; TASK PERFORMANCE; THREE DIMENSIONAL IMAGING; TOOTH CROWN; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 77956292105     PISSN: 00028177     EISSN: None     Source Type: Journal    
DOI: 10.14219/jada.archive.2010.0357     Document Type: Article
Times cited : (80)

References (10)
  • 1
    • 33749265329 scopus 로고    scopus 로고
    • Clinical performance of chairside CAD/CAM restorations
    • Fasbinder, DJ, Clinical performance of chairside CAD/CAM restorations. JADA 137:9 suppl (2006), 22S–31S.
    • (2006) JADA , vol.137 , Issue.9 , pp. 22S-31S
    • Fasbinder, D.J.1
  • 2
    • 33749254614 scopus 로고    scopus 로고
    • Materials for chairside CAD/CAM-produced restorations
    • Giordano, R, Materials for chairside CAD/CAM-produced restorations. JADA 137:9 suppl (2006), 14S–21S.
    • (2006) JADA , vol.137 , Issue.9 , pp. 14S-21S
    • Giordano, R.1
  • 3
    • 77649205143 scopus 로고    scopus 로고
    • A systematic review of the clinical performance of CAD/CAM single-tooth restorations
    • Wittneben, JG, Wright, RF, Weber, HP, Gallucci, GO, A systematic review of the clinical performance of CAD/CAM single-tooth restorations. Int J Prosthodont 22:5 (2009), 466–471.
    • (2009) Int J Prosthodont , vol.22 , Issue.5 , pp. 466-471
    • Wittneben, J.G.1    Wright, R.F.2    Weber, H.P.3    Gallucci, G.O.4
  • 5
    • 54049149919 scopus 로고    scopus 로고
    • Quadrant rehabilitation with implants and CAD/CAM crowns
    • 124, 126 passim.
    • Griffin, JD Jr, Quadrant rehabilitation with implants and CAD/CAM crowns. Dent Today, 27(9), 2008, 122 124, 126 passim.
    • (2008) Dent Today , vol.27 , Issue.9 , pp. 122
    • Griffin, J.D.1
  • 7
    • 29144507753 scopus 로고    scopus 로고
    • Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns
    • Bindl, A, Lüthy, H, Mörmann, WH, Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns. Dent Mater 22:1 (2006), 29–36.
    • (2006) Dent Mater , vol.22 , Issue.1 , pp. 29-36
    • Bindl, A.1    Lüthy, H.2    Mörmann, W.H.3
  • 8
    • 84989591508 scopus 로고
    • A novel bite force recorder and maximal isometric bite force values for healthy young adults
    • Waltimo, A, Könönen, M, A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:3 (1993), 171–175.
    • (1993) Scand J Dent Res , vol.101 , Issue.3 , pp. 171-175
    • Waltimo, A.1    Könönen, M.2
  • 9
    • 85005413838 scopus 로고
    • Maximal contraction force and endurance of human jaw-closing muscles in isometric clenching
    • Waltimo, A, Kemppainen, P, Könönen, M, Maximal contraction force and endurance of human jaw-closing muscles in isometric clenching. Scand J Dent Res 101:6 (1993), 416–421.
    • (1993) Scand J Dent Res , vol.101 , Issue.6 , pp. 416-421
    • Waltimo, A.1    Kemppainen, P.2    Könönen, M.3
  • 10
    • 70350007810 scopus 로고    scopus 로고
    • Accuracy of a newly developed integrated system for dental implant planning
    • Dreiseidler, T, Neugebauer, J, Ritter, L, et al. Accuracy of a newly developed integrated system for dental implant planning. Clin Oral Implants Res 20:11 (2009), 1191–1199.
    • (2009) Clin Oral Implants Res , vol.20 , Issue.11 , pp. 1191-1199
    • Dreiseidler, T.1    Neugebauer, J.2    Ritter, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.