메뉴 건너뛰기




Volumn 18, Issue 11, 2010, Pages 1532-1541

Biomechanical evaluation of a medial knee reconstruction with comparison of bioabsorbable interference screw constructs and optimization with a cortical button

Author keywords

Biomechanics; Cortical button; Interference screw; Superficial medial collateral ligament

Indexed keywords

ALLOTRANSPLANTATION; ANALYSIS OF VARIANCE; ANIMAL; ANIMAL MODEL; ARTICLE; BIODEGRADABLE IMPLANT; BIOMECHANICS; BONE DENSITY; BONE SCREW; CATTLE; COMPARATIVE STUDY; KNEE; KNEE LIGAMENT; MATERIALS TESTING; MECHANICAL STRESS; METHODOLOGY; PLASTIC SURGERY; PROSTHESIS; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY; SWINE; TENDON; TENSILE STRENGTH; TIBIA; TRANSPLANTATION;

EID: 77956260448     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-010-1127-z     Document Type: Article
Times cited : (18)

References (39)
  • 1
    • 0029914015 scopus 로고    scopus 로고
    • Total and regional bone mass in female soccer players
    • Alfredson H, Nordstrom P, Lorentzon R (1996) Total and regional bone mass in female soccer players. Calcif Tissue Int 59: 438-442.
    • (1996) Calcif Tissue Int , vol.59 , pp. 438-442
    • Alfredson, H.1    Nordstrom, P.2    Lorentzon, R.3
  • 2
    • 53949121629 scopus 로고    scopus 로고
    • Medial collateral ligament reconstruction with allograft using a double-bundle technique
    • Borden PS, Kantaras AT, Caborn DN (2002) Medial collateral ligament reconstruction with allograft using a double-bundle technique. Arthroscopy 18: E19.
    • (2002) Arthroscopy , vol.18
    • Borden, P.S.1    Kantaras, A.T.2    Caborn, D.N.3
  • 3
    • 0012631371 scopus 로고
    • Transplantation of the semitendinosus for repair of laceration of medial collateral ligament of the knee
    • Bosworth DM (1952) Transplantation of the semitendinosus for repair of laceration of medial collateral ligament of the knee. J Bone Joint Surg Am 34-A: 196-202.
    • (1952) J Bone Joint Surg Am , vol.34 A , pp. 196-202
    • Bosworth, D.M.1
  • 4
    • 0033802701 scopus 로고    scopus 로고
    • Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque
    • Brand JC Jr, Pienkowski D, Steenlage E, Hamilton D, Johnson DL, Caborn DNM (2000) Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am J Sports Med 28: 705-710.
    • (2000) Am J Sports Med , vol.28 , pp. 705-710
    • Brand Jr., J.C.1    Pienkowski, D.2    Steenlage, E.3    Hamilton, D.4    Johnson, D.L.5    Caborn, D.N.M.6
  • 5
    • 21444442026 scopus 로고    scopus 로고
    • Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35-mm delta screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae
    • Chang HC, Nyland J, Nawab A, Burden R, Caborn DN (2005) Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35-mm delta screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae. Am J Sports Med 33: 1057-1064.
    • (2005) Am J Sports Med , vol.33 , pp. 1057-1064
    • Chang, H.C.1    Nyland, J.2    Nawab, A.3    Burden, R.4    Caborn, D.N.5
  • 6
    • 0034321805 scopus 로고    scopus 로고
    • Technical note: alternative soft-tissue graft preparation technique for cruciate ligament reconstruction
    • Charlick DA, Caborn DN (2000) Technical note: alternative soft-tissue graft preparation technique for cruciate ligament reconstruction. Arthroscopy 16: E20.
    • (2000) Arthroscopy , vol.16
    • Charlick, D.A.1    Caborn, D.N.2
  • 8
    • 0025389116 scopus 로고
    • Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone
    • Daniels AU, Chang MK, Andriano KP (1990) Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone. J Appl Biomater 1: 57-78.
    • (1990) J Appl Biomater , vol.1 , pp. 57-78
    • Daniels, A.U.1    Chang, M.K.2    Andriano, K.P.3
  • 9
    • 67649497005 scopus 로고    scopus 로고
    • Biomechanical comparison of medial collateral ligament reconstructions using computer-assisted navigation
    • Feeley BT, Muller MS, Allen AA, Granchi CC, Pearle AD (2009) Biomechanical comparison of medial collateral ligament reconstructions using computer-assisted navigation. Am J Sports Med 37: 1123-1130.
    • (2009) Am J Sports Med , vol.37 , pp. 1123-1130
    • Feeley, B.T.1    Muller, M.S.2    Allen, A.A.3    Granchi, C.C.4    Pearle, A.D.5
  • 10
    • 70649099893 scopus 로고    scopus 로고
    • Medial knee injury: part 1, static function of the individual components of the main medial knee structures
    • Griffith CJ, LaPrade RF, Johansen S, Armitage B, Wijdicks C, Engebretsen L (2009) Medial knee injury: part 1, static function of the individual components of the main medial knee structures. Am J Sports Med 37: 1762-1770.
    • (2009) Am J Sports Med , vol.37 , pp. 1762-1770
    • Griffith, C.J.1    Laprade, R.F.2    Johansen, S.3    Armitage, B.4    Wijdicks, C.5    Engebretsen, L.6
  • 11
    • 58149269114 scopus 로고    scopus 로고
    • Force measurements on the posterior oblique ligament and superficial medial collateral ligament proximal and distal divisions to applied loads
    • Griffith CJ, Wijdicks CA, LaPrade RF, Armitage BM, Johansen S, Engebretsen L (2009) Force measurements on the posterior oblique ligament and superficial medial collateral ligament proximal and distal divisions to applied loads. Am J Sports Med 37: 140-148.
    • (2009) Am J Sports Med , vol.37 , pp. 140-148
    • Griffith, C.J.1    Wijdicks, C.A.2    Laprade, R.F.3    Armitage, B.M.4    Johansen, S.5    Engebretsen, L.6
  • 12
    • 0025453134 scopus 로고
    • The effects of test environment and cyclic stretching on the failure properties of human patellar tendons
    • Haut RC, Powlison AC (1990) The effects of test environment and cyclic stretching on the failure properties of human patellar tendons. J Orthop Res 8: 532-540.
    • (1990) J Orthop Res , vol.8 , pp. 532-540
    • Haut, R.C.1    Powlison, A.C.2
  • 13
    • 0036329978 scopus 로고    scopus 로고
    • Bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction: an in vitro comparison of mechanical behavior under failure tensile loading and cyclic submaximal tensile loading
    • Honl M, Carrero V, Hille E, Schneider E, Morlock MM (2002) Bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction: an in vitro comparison of mechanical behavior under failure tensile loading and cyclic submaximal tensile loading. Am J Sports Med 30: 549-557.
    • (2002) Am J Sports Med , vol.30 , pp. 549-557
    • Honl, M.1    Carrero, V.2    Hille, E.3    Schneider, E.4    Morlock, M.M.5
  • 14
    • 0028006685 scopus 로고
    • The importance of the posterior oblique ligament in repairs of acute tears of the medial ligaments in knees with and without an associated rupture of the anterior cruciate ligament. Results of long-term follow-up
    • Hughston JC (1994) The importance of the posterior oblique ligament in repairs of acute tears of the medial ligaments in knees with and without an associated rupture of the anterior cruciate ligament. Results of long-term follow-up. J Bone Joint Surg Am 76: 1328-1344.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1328-1344
    • Hughston, J.C.1
  • 15
    • 0023853258 scopus 로고
    • Long-term results of conservatively treated medial collateral ligament injuries of the knee joint
    • Kannus P (1988) Long-term results of conservatively treated medial collateral ligament injuries of the knee joint. Clin Orthop Relat Res 226: 103-112.
    • (1994) Clin Orthop Relat Res , vol.226 , pp. 103-112
    • Kannus, P.1
  • 16
    • 0037346994 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site
    • Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site. Am J Sports Med 31: 182-188.
    • (2003) Am J Sports Med , vol.31 , pp. 182-188
    • Kousa, P.1    Jarvinen, T.L.2    Vihavainen, M.3    Kannus, P.4    Jarvinen, M.5
  • 18
    • 67649565525 scopus 로고    scopus 로고
    • Anatomical reconstruction of the medial collateral ligament and posteromedial corner of the knee in patients with chronic medial collateral ligament instability
    • Lind M, Jakobsen BW, Lund B, Hansen MS, Abdallah O, Christiansen SE (2009) Anatomical reconstruction of the medial collateral ligament and posteromedial corner of the knee in patients with chronic medial collateral ligament instability. Am J Sports Med 37: 1116-1122.
    • (2009) Am J Sports Med , vol.37 , pp. 1116-1122
    • Lind, M.1    Jakobsen, B.W.2    Lund, B.3    Hansen, M.S.4    Abdallah, O.5    Christiansen, S.E.6
  • 19
    • 0001993993 scopus 로고
    • The incidence of knee ligament injuries in the general population
    • Miyasaka KC, Daniel DM, Stone ML (1991) The incidence of knee ligament injuries in the general population. Am J Knee Surg 4: 3-8.
    • (1991) Am J Knee Surg , vol.4 , pp. 3-8
    • Miyasaka, K.C.1    Daniel, D.M.2    Stone, M.L.3
  • 20
    • 0035121512 scopus 로고    scopus 로고
    • Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation
    • Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29: 67-71.
    • (2001) Am J Sports Med , vol.29 , pp. 67-71
    • Nagarkatti, D.G.1    McKeon, B.P.2    Donahue, B.S.3    Fulkerson, J.P.4
  • 21
    • 0037269438 scopus 로고    scopus 로고
    • Modeling elite male athletes' peripheral bone mass, assessed using regional dual X-ray absorptiometry
    • Nevill AM, Holder RL, Stewart AD (2003) Modeling elite male athletes' peripheral bone mass, assessed using regional dual X-ray absorptiometry. Bone 32: 62-68.
    • (2003) Bone , vol.32 , pp. 62-68
    • Nevill, A.M.1    Holder, R.L.2    Stewart, A.D.3
  • 22
    • 0029857872 scopus 로고    scopus 로고
    • Site-specific bone mass differences of the lower extremities in 17-year-old ice hockey players
    • Nordstrom P, Lorentzon R (1996) Site-specific bone mass differences of the lower extremities in 17-year-old ice hockey players. Calcif Tissue Int 59: 443-448.
    • (1996) Calcif Tissue Int , vol.59 , pp. 443-448
    • Nordstrom, P.1    Lorentzon, R.2
  • 23
    • 0029117985 scopus 로고
    • The treatment of acute combined ruptures of the anterior cruciate and medial ligaments of the knee
    • Noyes FR, Barber-Westin SD (1995) The treatment of acute combined ruptures of the anterior cruciate and medial ligaments of the knee. Am J Sports Med 23: 380-389.
    • (1995) Am J Sports Med , vol.23 , pp. 380-389
    • Noyes, F.R.1    Barber-Westin, S.D.2
  • 25
    • 37349009642 scopus 로고    scopus 로고
    • Minimally invasive medial collateral ligament reconstruction using achilles tendon allograft
    • Rue J, Lewis PB, Detterline AJ, Verma N, Bach BR (2007) Minimally invasive medial collateral ligament reconstruction using achilles tendon allograft. Tech Knee Surg 6: 266.
    • (2007) Tech Knee Surg , vol.6 , pp. 266
    • Rue, J.1    Lewis, P.B.2    Detterline, A.J.3    Verma, N.4    Bach, B.R.5
  • 26
    • 0028910292 scopus 로고
    • Medial collateral ligament injuries: evaluation of multiple signs, prevalence and location of associated bone bruises, and assessment with MR imaging
    • Schweitzer ME, Tran D, Deely DM, Hume EL (1995) Medial collateral ligament injuries: evaluation of multiple signs, prevalence and location of associated bone bruises, and assessment with MR imaging. Radiology 194: 825-829.
    • (1995) Radiology , vol.194 , pp. 825-829
    • Schweitzer, M.E.1    Tran, D.2    Deely, D.M.3    Hume, E.L.4
  • 27
    • 0031730815 scopus 로고    scopus 로고
    • Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model
    • Seil R, Rupp S, Krauss PW, Benz A, Kohn DM (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26: 815-819.
    • (1998) Am J Sports Med , vol.26 , pp. 815-819
    • Seil, R.1    Rupp, S.2    Krauss, P.W.3    Benz, A.4    Kohn, D.M.5
  • 28
    • 54049136943 scopus 로고    scopus 로고
    • Distal biceps repair using cortical button fixation
    • Sethi PM, Tibone JE (2008) Distal biceps repair using cortical button fixation. Sports Med Arthrosc 16: 130-135.
    • (2008) Sports Med Arthrosc , vol.16 , pp. 130-135
    • Sethi, P.M.1    Tibone, J.E.2
  • 29
    • 71649089105 scopus 로고    scopus 로고
    • Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation
    • Sethi P, Obopilwe E, Rincon L, Miller S, Mazzocca A (2010) Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation. J Shoulder Elbow Surg 19: 53-57.
    • (2010) J Shoulder Elbow Surg , vol.19 , pp. 53-57
    • Sethi, P.1    Obopilwe, E.2    Rincon, L.3    Miller, S.4    Mazzocca, A.5
  • 30
    • 0014262122 scopus 로고
    • Rotatory instability of the knee. Its pathogenesis and a clinical test to demonstrate its presence
    • Slocum DB, Larson RL (1968) Rotatory instability of the knee. Its pathogenesis and a clinical test to demonstrate its presence. J Bone Joint Surg Am 50: 211-225.
    • (1968) J Bone Joint Surg Am , vol.50 , pp. 211-225
    • Slocum, D.B.1    Larson, R.L.2
  • 31
    • 33748064667 scopus 로고    scopus 로고
    • Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws
    • Tecklenburg K, Burkart P, Hoser C, Rieger M, Fink C (2006) Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws. Arthroscopy 22: 993-999.
    • (2006) Arthroscopy , vol.22 , pp. 993-999
    • Tecklenburg, K.1    Burkart, P.2    Hoser, C.3    Rieger, M.4    Fink, C.5
  • 32
    • 70449714162 scopus 로고    scopus 로고
    • The 1:1 versus the 2:2 tunnel-drilling technique: optimization of fixation strength and stiffness in an all-inside double-bundle anterior cruciate ligament reconstruction-a biomechanical study
    • Walsh MP, Wijdicks CA, Armitage BM, Westerhaus BD, Parker JB, Laprade RF (2009) The 1: 1 versus the 2: 2 tunnel-drilling technique: optimization of fixation strength and stiffness in an all-inside double-bundle anterior cruciate ligament reconstruction-a biomechanical study. Am J Sports Med 37: 1539-1547.
    • (2009) Am J Sports Med , vol.37 , pp. 1539-1547
    • Walsh, M.P.1    Wijdicks, C.A.2    Armitage, B.M.3    Westerhaus, B.D.4    Parker, J.B.5    Laprade, R.F.6
  • 33
    • 58149231143 scopus 로고    scopus 로고
    • A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model
    • Walsh MP, Wijdicks CA, Parker JB, Hapa O, LaPrade RF (2009) A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model. Am J Sports Med 37: 160-167.
    • (2009) Am J Sports Med , vol.37 , pp. 160-167
    • Walsh, M.P.1    Wijdicks, C.A.2    Parker, J.B.3    Hapa, O.4    Laprade, R.F.5
  • 36
    • 0032727741 scopus 로고    scopus 로고
    • The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions
    • Yamanaka M, Yasuda K, Tohyama H, Nakano H, Wada T (1999) The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions. Am J Sports Med 27: 772-777.
    • (1999) Am J Sports Med , vol.27 , pp. 772-777
    • Yamanaka, M.1    Yasuda, K.2    Tohyama, H.3    Nakano, H.4    Wada, T.5
  • 37
    • 43049102763 scopus 로고    scopus 로고
    • An in vivo biomechanical study on the tension-versus-knee flexion angle curves of 2 grafts in anatomic double-bundle anterior cruciate ligament reconstruction: effects of initial tension and internal tibial rotation
    • Yasuda K, Ichiyama H, Kondo E, Miyatake S, Inoue M, Tanabe Y (2008) An in vivo biomechanical study on the tension-versus-knee flexion angle curves of 2 grafts in anatomic double-bundle anterior cruciate ligament reconstruction: effects of initial tension and internal tibial rotation. Arthroscopy 24: 276-284.
    • (2008) Arthroscopy , vol.24 , pp. 276-284
    • Yasuda, K.1    Ichiyama, H.2    Kondo, E.3    Miyatake, S.4    Inoue, M.5    Tanabe, Y.6
  • 38
    • 10044246174 scopus 로고    scopus 로고
    • Anatomic reconstruction of the anteromedial and posterolateral bundles of the anterior cruciate ligament using hamstring tendon grafts
    • Yasuda K, Kondo E, Ichiyama H, Kitamura N, Tanabe Y, Tohyama H, Minami A (2004) Anatomic reconstruction of the anteromedial and posterolateral bundles of the anterior cruciate ligament using hamstring tendon grafts. Arthroscopy 20: 1015-1025.
    • (2004) Arthroscopy , vol.20 , pp. 1015-1025
    • Yasuda, K.1    Kondo, E.2    Ichiyama, H.3    Kitamura, N.4    Tanabe, Y.5    Tohyama, H.6    Minami, A.7
  • 39
    • 23944432985 scopus 로고    scopus 로고
    • Medial collateral ligament reconstruction using autogenous hamstring tendons: technique and results in initial cases
    • Yoshiya S, Kuroda R, Mizuno K, Yamamoto T, Kurosaka M (2005) Medial collateral ligament reconstruction using autogenous hamstring tendons: technique and results in initial cases. Am J Sports Med 33: 1380-1385.
    • (2005) Am J Sports Med , vol.33 , pp. 1380-1385
    • Yoshiya, S.1    Kuroda, R.2    Mizuno, K.3    Yamamoto, T.4    Kurosaka, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.