메뉴 건너뛰기




Volumn 46, Issue 1, 2011, Pages 75-81

Distributions of respiratory contaminants from a patient with different postures and exhaling modes in a single-bed inpatient room

Author keywords

Breath; Cough; Displacement ventilation; Inpatient room; Mixing ventilation; Posture

Indexed keywords

BREATH; COUGH; DISPLACEMENT VENTILATION; INPATIENT ROOM; MIXING VENTILATION; POSTURE;

EID: 77956225029     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2010.07.003     Document Type: Article
Times cited : (49)

References (16)
  • 1
    • 1942467995 scopus 로고    scopus 로고
    • Evidence of airborne transmission of the severe acute respiratory syndrome virus
    • Yu I.T.S., Li Y., Wong T.W., Tam W., Chan A.T., Lee J.W., et al. Evidence of airborne transmission of the severe acute respiratory syndrome virus. New England Journal of Medicine 2004, 350(17):1731-1739.
    • (2004) New England Journal of Medicine , vol.350 , Issue.17 , pp. 1731-1739
    • Yu, I.T.S.1    Li, Y.2    Wong, T.W.3    Tam, W.4    Chan, A.T.5    Lee, J.W.6
  • 2
    • 51449094788 scopus 로고    scopus 로고
    • Transport of exhaled particulate matter in airborne infection isolation rooms
    • Richmond-Bryant J. Transport of exhaled particulate matter in airborne infection isolation rooms. Building and Environment 2009, 44(1):44-55.
    • (2009) Building and Environment , vol.44 , Issue.1 , pp. 44-55
    • Richmond-Bryant, J.1
  • 3
    • 33846592867 scopus 로고    scopus 로고
    • Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review
    • Li Y., Leung G.M., Tang J.W., Yang X., Chao C.Y.H., Lin J.Z., et al. Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. Indoor Air 2007, 17(2):2-18.
    • (2007) Indoor Air , vol.17 , Issue.2 , pp. 2-18
    • Li, Y.1    Leung, G.M.2    Tang, J.W.3    Yang, X.4    Chao, C.Y.H.5    Lin, J.Z.6
  • 4
    • 33750629996 scopus 로고    scopus 로고
    • Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises
    • Tang J.W., Li Y., Eames I., Chan P.K.S., Ridgway G.L. Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. Journal of Hospital Infection 2006, 64(2):100-114.
    • (2006) Journal of Hospital Infection , vol.64 , Issue.2 , pp. 100-114
    • Tang, J.W.1    Li, Y.2    Eames, I.3    Chan, P.K.S.4    Ridgway, G.L.5
  • 6
    • 35448960371 scopus 로고    scopus 로고
    • Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system
    • Qian H., Li Y., Nielsen P.V., Hylgaard C.E. Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system. Building and Environment 2008, 43(3):344-354.
    • (2008) Building and Environment , vol.43 , Issue.3 , pp. 344-354
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Hylgaard, C.E.4
  • 7
    • 33748325891 scopus 로고    scopus 로고
    • Droplet fate in indoor environment, or can we prevent the spread of infection?
    • Morawska L. Droplet fate in indoor environment, or can we prevent the spread of infection?. Indoor Air 2006, 16(5):335-347.
    • (2006) Indoor Air , vol.16 , Issue.5 , pp. 335-347
    • Morawska, L.1
  • 8
    • 70450163033 scopus 로고    scopus 로고
    • Flow dynamics and characterization of a cough
    • Gupta J.K., Lin C.H., Chen Q. Flow dynamics and characterization of a cough. Indoor Air 2009, 19(6):517-525.
    • (2009) Indoor Air , vol.19 , Issue.6 , pp. 517-525
    • Gupta, J.K.1    Lin, C.H.2    Chen, Q.3
  • 9
    • 33646674108 scopus 로고    scopus 로고
    • Investigation into airborne characteristics of airflow due to coughing in a stagnant indoor environment
    • Zhu S., Kato S., Yang J.H. Investigation into airborne characteristics of airflow due to coughing in a stagnant indoor environment. ASHRAE Transactions 2006, 112(1):123-133.
    • (2006) ASHRAE Transactions , vol.112 , Issue.1 , pp. 123-133
    • Zhu, S.1    Kato, S.2    Yang, J.H.3
  • 10
    • 33846635560 scopus 로고    scopus 로고
    • Measurement and prediction of indoor air quality using a breathing thermal manikin
    • Melikov A., Kaczmarczyk J. Measurement and prediction of indoor air quality using a breathing thermal manikin. Indoor Air 2007, 17(1):50-59.
    • (2007) Indoor Air , vol.17 , Issue.1 , pp. 50-59
    • Melikov, A.1    Kaczmarczyk, J.2
  • 11
    • 36248936692 scopus 로고    scopus 로고
    • Transport of droplets expelled by coughing in ventilated rooms
    • Sun W., Ji J. Transport of droplets expelled by coughing in ventilated rooms. Indoor and Built Environment 2007, 16(6):493-504.
    • (2007) Indoor and Built Environment , vol.16 , Issue.6 , pp. 493-504
    • Sun, W.1    Ji, J.2
  • 12
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilation rooms
    • Bjørn E., Nielsen P.V. Dispersal of exhaled air and personal exposure in displacement ventilation rooms. Indoor Air 2002, 12(3):147-164.
    • (2002) Indoor Air , vol.12 , Issue.3 , pp. 147-164
    • Bjørn, E.1    Nielsen, P.V.2
  • 13
    • 33644697163 scopus 로고    scopus 로고
    • Dispersion of exhaled droplet nuclei in a two-bed ward with three different ventilation systems
    • Qian H., Li Y., Nielsen P.V., Hyldgaard C.E., Wong T.W., Chwang A.T.Y. Dispersion of exhaled droplet nuclei in a two-bed ward with three different ventilation systems. Indoor Air 2006, 16(2):111-128.
    • (2006) Indoor Air , vol.16 , Issue.2 , pp. 111-128
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Hyldgaard, C.E.4    Wong, T.W.5    Chwang, A.T.Y.6
  • 14
  • 15
    • 59849085957 scopus 로고    scopus 로고
    • Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities
    • Morawska L., Johnson G.R., Ristovski Z.D., Hargreaves M., Mengersen K., Corbett S., et al. Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. Journal of Aerosol Science 2009, 40(3):256-269.
    • (2009) Journal of Aerosol Science , vol.40 , Issue.3 , pp. 256-269
    • Morawska, L.1    Johnson, G.R.2    Ristovski, Z.D.3    Hargreaves, M.4    Mengersen, K.5    Corbett, S.6
  • 16
    • 45949091378 scopus 로고    scopus 로고
    • Transport and removal of expiratory droplets in hospital ward environment
    • Chao C.Y.H., Wan M.P., Sze To G.N. Transport and removal of expiratory droplets in hospital ward environment. Aerosol Science and Technology 2008, 42(5):377-394.
    • (2008) Aerosol Science and Technology , vol.42 , Issue.5 , pp. 377-394
    • Chao, C.Y.H.1    Wan, M.P.2    Sze To, G.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.