메뉴 건너뛰기




Volumn 43, Issue 3, 2008, Pages 344-354

Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system

Author keywords

Airborne transmission; Breathing exhalation jet; Downward ventilation; Flow visualization; Hospital ventilation; Infection control

Indexed keywords

AIR ENTRAINMENT; AIR POLLUTION; COMPUTATIONAL FLUID DYNAMICS; DIFFUSION; FLOW PATTERNS; FLOW VISUALIZATION; HEALTH RISKS; HOSPITALS; LAMINAR FLOW; THERMAL PLUMES; TURBULENT FLOW;

EID: 35448960371     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2006.03.025     Document Type: Article
Times cited : (140)

References (18)
  • 1
    • 15744393009 scopus 로고    scopus 로고
    • Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
    • Li Y., Huang X., Yu I.T.S., Wong T.W., and Qian H. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. Indoor Air 15 2 (2005) 83-95
    • (2005) Indoor Air , vol.15 , Issue.2 , pp. 83-95
    • Li, Y.1    Huang, X.2    Yu, I.T.S.3    Wong, T.W.4    Qian, H.5
  • 2
    • 77957178387 scopus 로고
    • On air-borne infection study: II-droplets and droplet nuclei
    • Wells W.F. On air-borne infection study: II-droplets and droplet nuclei. American Journal of Hygiene 20 (1934) 619-627
    • (1934) American Journal of Hygiene , vol.20 , pp. 619-627
    • Wells, W.F.1
  • 4
    • 17444368830 scopus 로고    scopus 로고
    • ASHRAE, American Society of Heating Refrigerating and Air-Conditioning Engineers Inc., Atlanta, GA
    • ASHRAE. HVAC design manual for hospitals and clinics (2003), American Society of Heating Refrigerating and Air-Conditioning Engineers Inc., Atlanta, GA
    • (2003) HVAC design manual for hospitals and clinics
  • 6
    • 8644263177 scopus 로고    scopus 로고
    • CDC, US Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, Atlanta, GA
    • CDC. Guidelines for environmental infection control in health-care facilities (2003), US Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, Atlanta, GA
    • (2003) Guidelines for environmental infection control in health-care facilities
  • 7
  • 8
    • 0142048870 scopus 로고
    • A re-evaluation of laminar air flow in hospital operating rooms
    • Pfost J.F. A re-evaluation of laminar air flow in hospital operating rooms. ASHRAE Transactions 87 2 (1981) 729-739
    • (1981) ASHRAE Transactions , vol.87 , Issue.2 , pp. 729-739
    • Pfost, J.F.1
  • 9
    • 0034700254 scopus 로고    scopus 로고
    • Hospital ventilation and risk for tuberculous infection in Canadian health care workers, Canadian collaborative group in Nosocomial transmission of TB
    • Menzies D., Fanning A., Yuan L., and FitzGerald J.M. Hospital ventilation and risk for tuberculous infection in Canadian health care workers, Canadian collaborative group in Nosocomial transmission of TB. Annals of Internal Medicine 133 (2000) 779-789
    • (2000) Annals of Internal Medicine , vol.133 , pp. 779-789
    • Menzies, D.1    Fanning, A.2    Yuan, L.3    FitzGerald, J.M.4
  • 10
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjørn E., and Nielsen P.V. Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Indoor Air 12 (2002) 147-164
    • (2002) Indoor Air , vol.12 , pp. 147-164
    • Bjørn, E.1    Nielsen, P.V.2
  • 11
  • 12
    • 35449000030 scopus 로고    scopus 로고
    • Brohus H. Personal exposure to contaminant sources in ventilated rooms. PhD. thesis, Department of Building and Structural Engineering, Aalborg University, Aalborg, Denmark, 1997.
  • 13
    • 4344606832 scopus 로고    scopus 로고
    • Fluent Inc, Fluent Inc., Lebanon, NH
    • Fluent Inc. Gambit 2.0 user's guide (2001), Fluent Inc., Lebanon, NH
    • (2001) Gambit 2.0 user's guide
  • 14
    • 0011783527 scopus 로고    scopus 로고
    • Fluent Inc, Fluent Inc., Lebanon, NH
    • Fluent Inc. Fluent 6.0 user's guide (2001), Fluent Inc., Lebanon, NH
    • (2001) Fluent 6.0 user's guide
  • 16
    • 35448947173 scopus 로고    scopus 로고
    • Qian H, Nielsen PV, Li Y, Hyldgaard CE. Airflow and contaminant distribution in hospital wards. In: Proceedings of the second international conference on building environment and public health, Shenzhen, China, 6-10 December 2004. p. 355-64.
  • 17
    • 33644697163 scopus 로고    scopus 로고
    • Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems
    • Qian H., Li Y., Nielsen P.V., Hyldgaard C.E., Wong T.W., and Chwang A.T.Y. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. Indoor Air 16 (2006) 111-128
    • (2006) Indoor Air , vol.16 , pp. 111-128
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Hyldgaard, C.E.4    Wong, T.W.5    Chwang, A.T.Y.6
  • 18
    • 0038298803 scopus 로고    scopus 로고
    • SARS: experience at prince of Wales Hospital, Hong Kong
    • Tomlinson B., and Cockram C. SARS: experience at prince of Wales Hospital, Hong Kong. Lancet 361 (2003) 1486-1487
    • (2003) Lancet , vol.361 , pp. 1486-1487
    • Tomlinson, B.1    Cockram, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.