메뉴 건너뛰기




Volumn 33, Issue 4, 2010, Pages 732-738

Günter tulip filter retrieval experience: Predictors of successful retrieval

Author keywords

Filter retrieval; Optional inferior vena cava filters

Indexed keywords

ADULT; ARTICLE; DEEP VEIN THROMBOSIS; DEMOGRAPHY; DEVICE REMOVAL; EXPERIENCE; FEMALE; FEMORAL VEIN; FLUOROSCOPY; FOLLOW UP; GUIDE WIRE; GUNTER TULIP FILTER; HUMAN; HYPERCOAGULABILITY; INFERIOR CAVA VEIN; INTERNAL JUGULAR VEIN; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; VENA CAVA FILTER;

EID: 77956189024     PISSN: 01741551     EISSN: 1432086X     Source Type: Journal    
DOI: 10.1007/s00270-009-9684-6     Document Type: Article
Times cited : (29)

References (11)
  • 1
    • 36949000074 scopus 로고    scopus 로고
    • Pulmonary embolism is an important cause of death in young adults
    • 10.1253/circj.71.1765 17965499
    • M Sakuma M Nakamura T Takahashi, et al. 2007 Pulmonary embolism is an important cause of death in young adults Circ J 71 11 1765 1770 10.1253/circj.71.1765 17965499
    • (2007) Circ J , vol.71 , Issue.11 , pp. 1765-1770
    • Sakuma, M.1    Nakamura, M.2    Takahashi, T.3
  • 2
    • 34748899407 scopus 로고    scopus 로고
    • Inferior vena cava filters in the management of venous thromboembolism
    • 10.1016/j.amjmed.2007.07.015 17916454
    • MA Crowther 2007 Inferior vena cava filters in the management of venous thromboembolism Am J Med 120 10; Suppl 2 S13 S17 10.1016/j.amjmed.2007.07.015 17916454
    • (2007) Am J Med , vol.120 , Issue.10 SUPPL. 2
    • Crowther, M.A.1
  • 3
    • 39449116099 scopus 로고    scopus 로고
    • Management of severe vena cava filter tilting: Experience with bard g-2 filters
    • 10.1016/j.jvir.2007.11.020 18295708
    • UC Turba C Glaiberman D Picus B Arslan JF Angle AH Matsumoto 2008 Management of severe vena cava filter tilting: experience with bard g-2 filters J Vasc Interv Radiol 19 3 449 453 10.1016/j.jvir.2007.11.020 18295708
    • (2008) J Vasc Interv Radiol , vol.19 , Issue.3 , pp. 449-453
    • Turba, U.C.1    Glaiberman, C.2    Picus, D.3    Arslan, B.4    Angle, J.F.5    Matsumoto, A.H.6
  • 4
    • 35448948777 scopus 로고    scopus 로고
    • Retrieval of a tilted Gunther Tulip filter with the superior hook embedded in the caval wall
    • 10.1016/j.jvir.2007.08.006 18004000
    • S Contractor N Bhagat Y Mahmood V Shenyzon T Clark 2007 Retrieval of a tilted Gunther Tulip filter with the superior hook embedded in the caval wall J Vasc Interv Radiol 18 11 1455 1456 10.1016/j.jvir.2007.08.006 18004000
    • (2007) J Vasc Interv Radiol , vol.18 , Issue.11 , pp. 1455-1456
    • Contractor, S.1    Bhagat, N.2    Mahmood, Y.3    Shenyzon, V.4    Clark, T.5
  • 5
    • 34648840844 scopus 로고    scopus 로고
    • Loop-snare technique for difficult inferior vena cava filter retrievals
    • 10.1016/j.jvir.2007.07.002 17911525
    • L Rubenstein AK Chun M Chew CA Binkert 2007 Loop-snare technique for difficult inferior vena cava filter retrievals J Vasc Interv Radiol 18 10 1315 1318 10.1016/j.jvir.2007.07.002 17911525
    • (2007) J Vasc Interv Radiol , vol.18 , Issue.10 , pp. 1315-1318
    • Rubenstein, L.1    Chun, A.K.2    Chew, M.3    Binkert, C.A.4
  • 6
    • 4644221063 scopus 로고    scopus 로고
    • Antithrombotic therapy for venous thromboembolic disease: The seventh ACCP conference on antithrombotic and thrombolytic therapy
    • 10.1378/chest.126.3-suppl.401S 1:CAS:528:DC%2BD2cXptV2msbo%3D 15383479
    • HR Buller G Agnelli RD Hull TM Hyers MH Prins GE Raskob 2004 Antithrombotic therapy for venous thromboembolic disease: the seventh ACCP conference on antithrombotic and thrombolytic therapy Chest 126 Suppl 3 401S 428S 10.1378/chest.126.3-suppl.401S 1:CAS:528:DC%2BD2cXptV2msbo%3D 15383479
    • (2004) Chest , vol.126 , Issue.SUPPL. 3
    • Buller, H.R.1    Agnelli, G.2    Hull, R.D.3    Hyers, T.M.4    Prins, M.H.5    Raskob, G.E.6
  • 7
    • 33747875019 scopus 로고    scopus 로고
    • Guidelines for the use of retrievable and convertible vena cava filters: Report from the society of interventional radiology multidisciplinary consensus conference
    • 10.1097/01.RVI.0000203418-39769.0D 16567669
    • JA Kaufman TB Kinney MB Streiff, et al. 2006 Guidelines for the use of retrievable and convertible vena cava filters: report from the society of interventional radiology multidisciplinary consensus conference J Vasc Interv Radiol 17 3 449 459 10.1097/01.RVI.0000203418-39769.0D 16567669
    • (2006) J Vasc Interv Radiol , vol.17 , Issue.3 , pp. 449-459
    • Kaufman, J.A.1    Kinney, T.B.2    Streiff, M.B.3
  • 8
    • 33845430407 scopus 로고    scopus 로고
    • Gunther Tulip retrievable inferior vena caval filters: Indications, efficacy, retrieval, and complications
    • 10.1007/s00270-006-0093-9 1:STN:280:DC%2BD28jgt12jsw%3D%3D
    • S Looby MF Given T Geoghegan A McErlean MJ Lee 2007 Gunther Tulip retrievable inferior vena caval filters: indications, efficacy, retrieval, and complications CardioVasc Interv Radiol 30 1 59 65 10.1007/s00270-006-0093-9 1:STN:280:DC%2BD28jgt12jsw%3D%3D
    • (2007) CardioVasc Interv Radiol , vol.30 , Issue.1 , pp. 59-65
    • Looby, S.1    Given, M.F.2    Geoghegan, T.3    McErlean, A.4    Lee, M.J.5
  • 9
    • 40949146154 scopus 로고    scopus 로고
    • The Gunther-Tulip retrievable IVC filter: Clinical experience in 118 consecutive patients
    • 10.1253/circj.72.287 18219168
    • S Ota N Yamada A Tsuji, et al. 2008 The Gunther-Tulip retrievable IVC filter: clinical experience in 118 consecutive patients Circ J 72 2 287 292 10.1253/circj.72.287 18219168
    • (2008) Circ J , vol.72 , Issue.2 , pp. 287-292
    • Ota, S.1    Yamada, N.2    Tsuji, A.3
  • 10
    • 33748199059 scopus 로고    scopus 로고
    • Gunther Tulip filter retrievability multicenter study including CT follow-up: Final report
    • 10.1097/01.RVI.90000223689.49091.76 16778236
    • H Hoppe CW Nutting HR Smouse, et al. 2006 Gunther Tulip filter retrievability multicenter study including CT follow-up: final report J Vasc Interv Radiol 17 6 1017 1023 10.1097/01.RVI.90000223689.49091.76 16778236
    • (2006) J Vasc Interv Radiol , vol.17 , Issue.6 , pp. 1017-1023
    • Hoppe, H.1    Nutting, C.W.2    Smouse, H.R.3
  • 11
    • 34447336136 scopus 로고    scopus 로고
    • Retrievability of the Gunther Tulip vena cava filter after dwell times longer than 180 days in patients with multiple trauma
    • 10.1583/06-2045.1 17723017
    • D Rosenthal ED Wellons SM Hancock AB Burkett 2007 Retrievability of the Gunther Tulip vena cava filter after dwell times longer than 180 days in patients with multiple trauma J Endovasc Ther 14 3 406 410 10.1583/06-2045.1 17723017
    • (2007) J Endovasc Ther , vol.14 , Issue.3 , pp. 406-410
    • Rosenthal, D.1    Wellons, E.D.2    Hancock, S.M.3    Burkett, A.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.