Design of a MEMS-based total phosphorus sensor with a microdigestion system

Author keywords

Cobalt; Microelectrode; Sensor; Total phosphorus

Indexed keywords

AUTOMATIC MEASUREMENTS; BUFFER SOLUTIONS; COBALT ELECTRODES; FABRICATION PROCESS; LINEAR RELATIONSHIPS; METAL FILM; MICRO DEVICES; MICROELECTROMECHANICAL SYSTEMS; PHOSPHATE IONS; SENSING MATERIAL; SENSING MECHANISM; TOTAL PHOSPHORUS; WATER ENVIRONMENTS;

EID: 77956153682     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICBBE.2010.5515051     Document Type: Conference Paper
Times cited : (6)

References (8)
  • 1
    • 0030176650 scopus 로고    scopus 로고
    • Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate
    • 1996.
    • R. K. Meruva, and M. E. Meyerhoff, 1996 "Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate," Anal. Chem., vol. 68, pp. 2022-2026,1996.
    • (1996) Anal. Chem. , vol.68 , pp. 2022-2026
    • Meruva, R.K.1    Meyerhoff, M.E.2
  • 2
    • 0001649268 scopus 로고
    • Surface-modified cobalt-based sensor as a phosphate-sensitive electrode
    • D. Xiao, H. Yuan, J. Li, and R. Yu, "Surface-Modified Cobalt-Based Sensor as a Phosphate-Sensitive Electrode," Anal. Chem., vol. 67, pp, 288-291,1995.
    • (1995) Anal. Chem. , vol.67 , pp. 288-291
    • Xiao, D.1    Yuan, H.2    Li, J.3    Yu, R.4
  • 3
    • 0039907244 scopus 로고    scopus 로고
    • Flow-injection potentiometrie detection of phosphates using a metallic cobalt wire ion-selective electrode
    • Z. Chen, R. D. Marco, and P. W. Alexander, "Flow-injection Potentiometrie Detection of Phosphates Using a Metallic Cobalt Wire Ion-selective Electrode," Analytical Communications, Vol. 34, pp. 93-95, 1997.
    • (1997) Analytical Communications , vol.34 , pp. 93-95
    • Chen, Z.1    Marco, R.D.2    Alexander, P.W.3
  • 4
    • 19944395204 scopus 로고    scopus 로고
    • Development of a phosphate ion-selective microelectrode and its use in studies of the enhanced biological phosphorus removal (ebpr) process
    • J. J. Wang, P. L, Bishop, "Development of a Phosphate Ion-selective Microelectrode and Its Use in Studies of the Enhanced Biological Phosphorus Removal (ebpr) Process," Environmental Technology, vol. 26, pp. 381-388,2005.
    • (2005) Environmental Technology , vol.26 , pp. 381-388
    • Wang, J.J.1    Bishop, P.L.2
  • 5
    • 33847415823 scopus 로고    scopus 로고
    • A disposable onchip phosphate sensor with, planar cobalt microelectrodes on polymer substrate
    • Z. Zhou, J. Han, A, Jiang, P. L.bishop, and C. H. Ahn, "A disposable onchip phosphate sensor with, planar cobalt microelectrodes on polymer substrate," Biosensors and. Bioelectronies, vol. 22, pp. 1902-1907,2007.
    • (2007) Biosensors And. Bioelectronies , vol.22 , pp. 1902-1907
    • Zhou, Z.1    Han, J.2    Jiang, A.3    Bishop, P.L.4    Ahn, C.H.5
  • 6
    • 61849156391 scopus 로고    scopus 로고
    • A. cobalt -coated needle-type microelectrode array sensor for in situ monitoring of phosphate
    • J. Lee, W. H. Lee, P. L. Bishop, and I. Papautsky, "A. cobalt -coated needle-type microelectrode array sensor for in situ monitoring of phosphate," J. Micromech. Microeng. Vol. 19, pp. 025022, 2009.
    • (2009) J. Micromech. Microeng. , vol.19 , pp. 025022
    • Lee, J.1    Lee, W.H.2    Bishop, P.L.3    Papautsky, I.4
  • 7
    • 35748934480 scopus 로고    scopus 로고
    • Needle-type dissolved oxygen microelectrode array sensors for in situ measurements
    • J. Lee, T. Lim, Y. Seo, P. L. Bishop, and I. Papautsky, "Needle-type dissolved oxygen microelectrode array sensors for in situ measurements," Sensors and Actuators B vol. 128, pp. 179-185,2007.
    • (2007) Sensors and Actuators B , vol.128 , pp. 179-185
    • Lee, J.1    Lim, T.2    Seo, Y.3    Bishop, P.L.4    Papautsky, I.5
  • 8
    • 0032433937 scopus 로고    scopus 로고
    • Determination of inorganic phosphate in a soil extract using a cobalt electrode
    • S. O. Engblom, "Determination of inorganic phosphate in a soil extract using a cobalt electrode. Plant Soil, vol. 206, pp. 173-179, 1999.
    • (1999) Plant Soil , vol.206 , pp. 173-179
    • Engblom, S.O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.