메뉴 건너뛰기




Volumn 96, Issue 17, 2010, Pages 1390-1395

The impact of acute reduction of continuous-flow left ventricular assist device support on cardiac and exercise performance

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AORTA VALVE; ARTICLE; CARDIOPULMONARY EXERCISE TEST; CLINICAL ARTICLE; EXERCISE; HEART ASSIST DEVICE; HEART FUNCTION; HEART LEFT ATRIUM PRESSURE; HEART LEFT VENTRICLE PRESSURE; HEART OUTPUT; HEART PERFORMANCE; HEART PRELOAD; HUMAN; LEFT VENTRICULAR ASSIST DEVICE; LUNG GAS EXCHANGE; LUNG HEMODYNAMICS; MALE; MEAN ARTERIAL PRESSURE; OXYGEN CONSUMPTION; PRIORITY JOURNAL; REBREATHING; COMPLICATION; CONGESTIVE CARDIOMYOPATHY; EVALUATION STUDY; EXERCISE TEST; EXERCISE TOLERANCE; HEART FAILURE; HYPERTROPHIC CARDIOMYOPATHY; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; PROCEDURES; TREATMENT OUTCOME; YOUNG ADULT;

EID: 77956118046     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/hrt.2010.193698     Document Type: Article
Times cited : (57)

References (36)
  • 1
    • 62249114891 scopus 로고    scopus 로고
    • Left ventricular device as destination therapy: Are we there yet?
    • Badiwala MV, Rao V. Left ventricular device as destination therapy: are we there yet? Curr Opin Cardiol 2009;24:184-9.
    • (2009) Curr Opin Cardiol , vol.24 , pp. 184-189
    • Badiwala, M.V.1    Rao, V.2
  • 2
    • 1642409474 scopus 로고    scopus 로고
    • The role of bridge to transplantation: Should LVAD patients be transplanted?
    • Birks EJ, Yacoub MH, Banner NR, et al. The role of bridge to transplantation: should LVAD patients be transplanted? Curr Opin Cardiol 2004;19:148-53.
    • (2004) Curr Opin Cardiol , vol.19 , pp. 148-153
    • Birks, E.J.1    Yacoub, M.H.2    Banner, N.R.3
  • 3
    • 33750500333 scopus 로고    scopus 로고
    • Left ventricular assist device and drug therapy for the reversal of heart failure
    • Birks EJ, Tansley PD, Hardy J, et al. Left ventricular assist device and drug therapy for the reversal of heart failure. N Eng J Med 2006;355:1873-84.
    • (2006) N Eng J Med , vol.355 , pp. 1873-1884
    • Birks, E.J.1    Tansley, P.D.2    Hardy, J.3
  • 4
    • 0035783884 scopus 로고    scopus 로고
    • Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    • Frazier OH, Rose EA, Oz MC, et al. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. J Thorac Cardiovas Surg 2001;122:1186-95.
    • (2001) J Thorac Cardiovas Surg , vol.122 , pp. 1186-1195
    • Frazier, O.H.1    Rose, E.A.2    Oz, M.C.3
  • 6
    • 52049104955 scopus 로고    scopus 로고
    • Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy
    • discussion 34-5
    • John R, Kamdar F, Liao K, et al. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy. Ann Thorac Surg 2008;86:1227-34; discussion 34-5.
    • (2008) Ann Thorac Surg , vol.86 , pp. 1227-1234
    • John, R.1    Kamdar, F.2    Liao, K.3
  • 7
    • 74249110561 scopus 로고    scopus 로고
    • European results with a continuous-flow ventricular assist device for advanced heart-failure patients
    • Lahpor J, Khaghani A, Hetzer R, et al. European results with a continuous-flow ventricular assist device for advanced heart-failure patients. Eur J Cardiothorac Surg 2010;37:357-61.
    • (2010) Eur J Cardiothorac Surg , vol.37 , pp. 357-361
    • Lahpor, J.1    Khaghani, A.2    Hetzer, R.3
  • 8
    • 27144517136 scopus 로고    scopus 로고
    • Long-term destination therapy with the HeartMate XVE left ventricular assist device: Improved outcomes since the REMATCH study
    • Long JW, Kfoury AG, Slaughter MS, et al. Long-term destination therapy with the HeartMate XVE left ventricular assist device: improved outcomes since the REMATCH study. Cong Heart Fail 2005;11:133-8.
    • (2005) Cong Heart Fail , vol.11 , pp. 133-138
    • Long, J.W.1    Kfoury, A.G.2    Slaughter, M.S.3
  • 9
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • HeartMate II Clinical Investigators
    • Miller LW, Pagani FD, Russell SD, et al. HeartMate II Clinical Investigators. Use of a continuous-flow device in patients awaiting heart transplantation. N Eng J Med 2007;357:885-96.
    • (2007) N Eng J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 10
    • 4344653744 scopus 로고    scopus 로고
    • Left ventricular assist device as destination for patients undergoing intravenous inotropic therapy: A subset analysis from REMATCH (Randomized Evaluation of Mechanical Assistance in Treatment of Chronic Heart Failure)
    • REMATCH Investigators
    • Stevenson LW, Miller LW, Desvigne-Nickens P, et al; REMATCH Investigators. Left ventricular assist device as destination for patients undergoing intravenous inotropic therapy: a subset analysis from REMATCH (Randomized Evaluation of Mechanical Assistance in Treatment of Chronic Heart Failure). Circulation 2004;110:975-81.
    • (2004) Circulation , vol.110 , pp. 975-981
    • Stevenson, L.W.1    Miller, L.W.2    Desvigne-Nickens, P.3
  • 11
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani FD, Miller LW, Russell SD, et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 2009;54:312-21.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 12
    • 24644481862 scopus 로고    scopus 로고
    • Long term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices
    • Dandel M, Weng Y, Siniawski H, et al. Long term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices. Circulation 2005;112(Suppl 9):I37-45.
    • (2005) Circulation , vol.112 , Issue.SUPPL. 9
    • Dandel, M.1    Weng, Y.2    Siniawski, H.3
  • 13
    • 34248586648 scopus 로고    scopus 로고
    • Cardiac improvement during mechanical circulatory support: A prospective multicenter study of the LVAD Working Group
    • LVAD Working Group
    • Maybaum S, Mancini D, Xydas S, et al. LVAD Working Group. Cardiac improvement during mechanical circulatory support: a prospective multicenter study of the LVAD Working Group. Circulation 2007;115:2497-505.
    • (2007) Circulation , vol.115 , pp. 2497-2505
    • Maybaum, S.1    Mancini, D.2    Xydas, S.3
  • 14
    • 24644466420 scopus 로고    scopus 로고
    • Myocardial recovery using venricular assist devices: Prevalance, clinical characteristics, and outcomes
    • Simon MA, Kormos RL, Murali S, et al. Myocardial recovery using venricular assist devices: prevalance, clinical characteristics, and outcomes. Circulation 2005;112(Suppl 9):I32-6.
    • (2005) Circulation , vol.112 , Issue.SUPPL. 9
    • Simon, M.A.1    Kormos, R.L.2    Murali, S.3
  • 15
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009;361:2241-51.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 16
    • 0034936375 scopus 로고    scopus 로고
    • A novel strategy to maximize the efficacy of left ventricular assist devices as a bridge to recovery
    • Yacoub MH. A novel strategy to maximize the efficacy of left ventricular assist devices as a bridge to recovery. Eur Heart J 2001;22:534-40.
    • (2001) Eur Heart J , vol.22 , pp. 534-540
    • Yacoub, M.H.1
  • 17
    • 0035106218 scopus 로고    scopus 로고
    • HeartMate II left ventricular assist system: From concept to first clinical use
    • Griffith BP, Kormos RL, Borovetz HS, et al. HeartMate II left ventricular assist system: from concept to first clinical use. Ann Thorac Surg 2001;71(Suppl III): S116-S20.
    • (2001) Ann Thorac Surg , vol.71 , Issue.SUPPL. III
    • Griffith, B.P.1    Kormos, R.L.2    Borovetz, H.S.3
  • 18
    • 27444433897 scopus 로고    scopus 로고
    • Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation
    • Agostoni P, Cattadori G, Apostolo A, et al. Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol 2005;46:1779-81.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1779-1781
    • Agostoni, P.1    Cattadori, G.2    Apostolo, A.3
  • 19
    • 38649131971 scopus 로고    scopus 로고
    • Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise
    • Jakovljevic DG, Nunan D, Donovan G, et al. Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise. Eur J Appl Physiol 2008;102:593-9.
    • (2008) Eur J Appl Physiol , vol.102 , pp. 593-599
    • Jakovljevic, D.G.1    Nunan, D.2    Donovan, G.3
  • 20
    • 0031947809 scopus 로고    scopus 로고
    • Physiological cardiac reserve: Development of a non-invasive method and first estimates in man
    • Cooke GA, Marshall P, Al-Timman JK, et al. Physiological cardiac reserve: development of a non-invasive method and first estimates in man. Heart 1998;79:289-94.
    • (1998) Heart , vol.79 , pp. 289-294
    • Cooke, G.A.1    Marshall, P.2    Al-Timman, J.K.3
  • 21
    • 34848928672 scopus 로고    scopus 로고
    • Hemodynamic and echocardiographic responses to acute interruption of left ventricular assist device support: Relevance to assessment of myocardial recovery
    • George RS, Yacoub MH, Tasca G, et al. Hemodynamic and echocardiographic responses to acute interruption of left ventricular assist device support: relevance to assessment of myocardial recovery. J Heart Lung Transplant 2007;26:967-73.
    • (2007) J Heart Lung Transplant , vol.26 , pp. 967-973
    • George, R.S.1    Yacoub, M.H.2    Tasca, G.3
  • 22
    • 0032404059 scopus 로고    scopus 로고
    • Low incidence of myocardial recovery after left ventricular assist device implantation in patients with chronic heart failure
    • Mancini DM, Beniaminovitz A, Levin H, et al. Low incidence of myocardial recovery after left ventricular assist device implantation in patients with chronic heart failure. Circulation 1998;98:2383-9.
    • (1998) Circulation , vol.98 , pp. 2383-2389
    • Mancini, D.M.1    Beniaminovitz, A.2    Levin, H.3
  • 23
    • 33645084581 scopus 로고    scopus 로고
    • Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device
    • Myers TJ, Frazier OH, Mesina HS, et al. Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device. J Heart Lung Transplant 2006;25:379-83.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 379-383
    • Myers, T.J.1    Frazier, O.H.2    Mesina, H.S.3
  • 24
    • 0037314334 scopus 로고    scopus 로고
    • Assessment of myocardial recovery in a patient with acute myocarditis supported with a left ventricular assist device: A case report
    • Maybaum S, Stockwell P, Naka Y, et al. Assessment of myocardial recovery in a patient with acute myocarditis supported with a left ventricular assist device: a case report. J Heart Lung Transplant 2003;22:202-9.
    • (2003) J Heart Lung Transplant , vol.22 , pp. 202-209
    • Maybaum, S.1    Stockwell, P.2    Naka, Y.3
  • 25
    • 0035135226 scopus 로고    scopus 로고
    • A new method of monitoring recovery and weaning the Thoratec left ventricular assist device
    • Slaughter MS, Silver MA, Farrar DJ, et al. A new method of monitoring recovery and weaning the Thoratec left ventricular assist device. Ann Thorac Surg 2001;71:215-18.
    • (2001) Ann Thorac Surg , vol.71 , pp. 215-218
    • Slaughter, M.S.1    Silver, M.A.2    Farrar, D.J.3
  • 26
    • 13444311967 scopus 로고    scopus 로고
    • Evaluation of myocardial function in patients with end-stage heart failure during support with the Jarvik 2000 left ventricular assist device
    • Ferrari M, Kadipasaoglu KA, Croitoru M, et al. Evaluation of myocardial function in patients with end-stage heart failure during support with the Jarvik 2000 left ventricular assist device. J Heart Lung Transplant 2005;24:226-8.
    • (2005) J Heart Lung Transplant , vol.24 , pp. 226-228
    • Ferrari, M.1    Kadipasaoglu, K.A.2    Croitoru, M.3
  • 27
    • 77954362067 scopus 로고    scopus 로고
    • Echocardiographic evaluation of flow across HeartMate II axial flow LVADs at varying low speeds
    • George RS, Sabharwal NK, Webb C, et al. Echocardiographic evaluation of flow across HeartMate II axial flow LVADs at varying low speeds. J Heart Lung Transplant 2009;28:2S.
    • (2009) J Heart Lung Transplant , vol.28
    • George, R.S.1    Sabharwal, N.K.2    Webb, C.3
  • 28
    • 0036233651 scopus 로고    scopus 로고
    • Long-term follow-up of Thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function
    • Farrar DJ, Holman WR, McBridge LR, et al. Long-term follow-up of Thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function. J Heart Lung Transplant 2002;21:516-21.
    • (2002) J Heart Lung Transplant , vol.21 , pp. 516-521
    • Farrar, D.J.1    Holman, W.R.2    McBridge, L.R.3
  • 29
    • 0022966489 scopus 로고
    • Cardiac pumping capability and prognosis in heart failure
    • Tan LB. Cardiac pumping capability and prognosis in heart failure. Lancet 1986;13:1360-3.
    • (1986) Lancet , vol.13 , pp. 1360-1363
    • Tan, L.B.1
  • 30
    • 85047678697 scopus 로고
    • Clinical and research implications of new concepts in the assessment of cardiac pumping performance in heart failure
    • Tan LB. Clinical and research implications of new concepts in the assessment of cardiac pumping performance in heart failure. Cardiovasc Res 1987;21:615-22.
    • (1987) Cardiovasc Res , vol.21 , pp. 615-622
    • Tan, L.B.1
  • 31
    • 0024349125 scopus 로고
    • Assessing cardiac pumping capability by exercise testing and inotropic stimulation
    • Tan LB, Bain RJ, Littler WA. Assessing cardiac pumping capability by exercise testing and inotropic stimulation. Br Heart J 1989;62:20-5.
    • (1989) Br Heart J , vol.62 , pp. 20-25
    • Tan, L.B.1    Bain, R.J.2    Littler, W.A.3
  • 32
    • 3242689898 scopus 로고    scopus 로고
    • Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: A report from the shock trial registry
    • Fincke R, Hochman JS, Lowe AM, et al. Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: a report from the shock trial registry. J Am Coll Cardiol 2004;44:340-8.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 340-348
    • Fincke, R.1    Hochman, J.S.2    Lowe, A.M.3
  • 33
    • 33847264414 scopus 로고    scopus 로고
    • Cardiac power output predicts mortality across a broad spectrum of patients with acute cardiac disease
    • Mendoza DD, Cooper HA, Panza JA. Cardiac power output predicts mortality across a broad spectrum of patients with acute cardiac disease. Am Heart J 2007;153:366-70.
    • (2007) Am Heart J , vol.153 , pp. 366-370
    • Mendoza, D.D.1    Cooper, H.A.2    Panza, J.A.3
  • 34
    • 0028809801 scopus 로고
    • Prognostic factors of chronic heart failure in NYHA class II or III: Value of invasive exercise haemodynamic data
    • Roul G, Moulichon ME, Bareiss P, et al. Prognostic factors of chronic heart failure in NYHA class II or III: value of invasive exercise haemodynamic data. Eur Heart J 1995;16:1387-98.
    • (1995) Eur Heart J , vol.16 , pp. 1387-1398
    • Roul, G.1    Moulichon, M.E.2    Bareiss, P.3
  • 35
    • 0025285445 scopus 로고
    • Measurement of cardiac reserve in cardiogenic shock: Implication for prognosis and management
    • Tan LB, Littler WA. Measurement of cardiac reserve in cardiogenic shock: implication for prognosis and management. Br Heart J 1990;64:121-8.
    • (1990) Br Heart J , vol.64 , pp. 121-128
    • Tan, L.B.1    Littler, W.A.2
  • 36
    • 0034891135 scopus 로고    scopus 로고
    • Peak exercise cardiac power output: A indicator of cardiac function strongly predictive of prognosis in chronic heart failure
    • Williams SG, Cooke GA, Wright DJ, et al. Peak exercise cardiac power output: a indicator of cardiac function strongly predictive of prognosis in chronic heart failure. Eur Heart J 2001;22:1496-503.
    • (2001) Eur Heart J , vol.22 , pp. 1496-1503
    • Williams, S.G.1    Cooke, G.A.2    Wright, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.