Volumn 182, Issue 9, 2010, Pages 773-779

Is it really not possible to use electronic personal dosimeters in clinical exposure situations?;Sind elektronische Personendosimeter in klinischen Expositionssituationen grundsätzlich nicht einsetzbar?

Author keywords

physics; radiation safety; technical aspects

Indexed keywords

ACCURACY; ARTICLE; DOSIMETER; ELECTRONIC PERSONAL DOSIMETER; MEASUREMENT ERROR; PHANTOM; PRIORITY JOURNAL; RADIATION; RADIATION DOSE; RADIATION EXPOSURE; RADIATION FIELD; RADIATION MEASUREMENT; RADIATION PROTECTION; RADIATION SCATTERING; ARTIFACT; BODY BURDEN; COMPARATIVE STUDY; DEVICES; EQUIPMENT DESIGN; HUMAN; IMAGE QUALITY; MICROCOMPUTER; RADIOGRAPHY; RADIOMETRY; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY;

EID: 77956031604     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0029-1245438     Document Type: Article
Times cited : (6)

References (16)
  • 1
    • 51549117964 scopus 로고    scopus 로고
    • Effective dose estimation in diagnostic radiology with two dosimeters: Impact of the 2007 recommendations of the ICRP
    • Boetticher H von, Lachmund J, Hoffmann W. Effective dose estimation in diagnostic radiology with two dosimeters: Impact of the 2007 recommendations of the ICRP. Health Physics 2008 95 337-340
    • (2008) Health Physics , vol.95 , pp. 337-340
    • Von, B.H.1    Lachmund, J.2    Hoffmann, W.3
  • 2
    • 47149095580 scopus 로고    scopus 로고
    • 2007 Recommendations of the ICRP change basis for estimation of the effective dose: What is the impact on radiation dose assessment of patient and personnel?
    • Boetticher H von, Lachmund J, Looe H K. et al. 2007 Recommendations of the ICRP change basis for estimation of the effective dose: What is the impact on radiation dose assessment of patient and personnel? Fortschr Röntgenstr 2008 180 391-395
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 391-395
    • Von, B.H.1    Lachmund, J.2    Looe, H.K.3
  • 3
    • 67651119736 scopus 로고    scopus 로고
    • Deficiencies of active electronic radiation protection dosemeters in pulsed fields
    • Ankerhold U, Hupe O, Ambrosi P. Deficiencies of active electronic radiation protection dosemeters in pulsed fields. Radiat Prot Dosimetry 2009 135 149-153
    • (2009) Radiat Prot Dosimetry , vol.135 , pp. 149-153
    • Ankerhold, U.1    Hupe, O.2    Ambrosi, P.3
  • 5
    • 55249124301 scopus 로고    scopus 로고
    • Intercomparison of active personal dosemeters in interventional radiology
    • Clairand I, Struelens L, Bordy J M. et al. Intercomparison of active personal dosemeters in interventional radiology. Radiat Prot Dosimetry 2008 129 340-345
    • (2008) Radiat Prot Dosimetry , vol.129 , pp. 340-345
    • Clairand, I.1    Struelens, L.2    Bordy, J.M.3
  • 8
    • 14944381949 scopus 로고    scopus 로고
    • Ist der Bleigleichwert zur Beurteilung der Schutzwirkung bleifreier Röntgenschutzkleidung geeignet?
    • Eder H, Panzer W, Schöfer H. Ist der Bleigleichwert zur Beurteilung der Schutzwirkung bleifreier Röntgenschutzkleidung geeignet? Fortschr Röntgenstr 2005 177 399-404
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 399-404
    • Eder, H.1    Panzer, W.2    Schöfer, H.3
  • 9
    • 56849108557 scopus 로고    scopus 로고
    • Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose area product values
    • Looe H K., Eenboom F, Chofor N et al. Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose area product values. Radiat Prot Dosimetry 2008 131 365-373
    • (2008) Radiat Prot Dosimetry , vol.131 , pp. 365-373
    • Looe, H.K.1    Eenboom, F.2    Chofor, N.3
  • 11
    • 0242409404 scopus 로고    scopus 로고
    • The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV Xrays to 60Co gamma rays
    • Davis S D., Ross C K., Mobit P N. et al. The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV Xrays to 60Co gamma rays. Radiat Prot Dosimetry 2003 106 33-43
    • (2003) Radiat Prot Dosimetry , vol.106 , pp. 33-43
    • Davis, S.D.1    Ross, C.K.2    Mobit, P.N.3
  • 13
    • 37449008827 scopus 로고    scopus 로고
    • Dose-Area Product measurements and determination of conversion factors for the estimation of effective dose in dental lateral cephalometric radiology
    • Looe H K., Eenboom F, Chofor N et al. Dose-Area Product measurements and determination of conversion factors for the estimation of effective dose in dental lateral cephalometric radiology. Radiat Prot Dosimetry 2007 124 181-186
    • (2007) Radiat Prot Dosimetry , vol.124 , pp. 181-186
    • Looe, H.K.1    Eenboom, F.2    Chofor, N.3
  • 14
    • 77957668959 scopus 로고    scopus 로고
    • Considerations concerning theuse of counting active personal dosemeters in pulsed fields of ionizing radiation
    • Ambrosi P, Borowski M, Iwatschenko M. Considerations concerning theuse of counting active personal dosemeters in pulsed fields of ionizing radiation. Radiat Prot Dosimetry 2010 1-11
    • (2010) Radiat Prot Dosimetry , pp. 1-11
    • Ambrosi, P.1    Borowski, M.2    Iwatschenko, M.3
  • 16
    • 0039808931 scopus 로고
    • Anforderungen an Personendosimeter
    • SSK
    • SSK. Anforderungen an Personendosimeter. Bundesanzeiger 1993 207 9817
    • (1993) Bundesanzeiger , vol.207 , pp. 9817


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.