메뉴 건너뛰기




Volumn 36, Issue 9, 2010, Pages 1535-1545

Amplitude-modulation chirp imaging for contrast detection

Author keywords

Amplitude modulation chirp imaging; Frequency sum and difference; Pulse compression

Indexed keywords

AXIAL RESOLUTIONS; BACK-SCATTERED; CHIRP IMAGING; CHIRP SIGNALS; CONTRAST-TO-TISSUE RATIO; CROSS SECTION; FREQUENCY-SUM AND -DIFFERENCE; HIGH FREQUENCY HF; HIGH FREQUENCY ULTRASOUNDS; HIGH RESOLUTION; IMAGING PULSE; LOW FREQUENCY; MICRO-VASCULATURE; MICROBUBBLES; MODULATION DEPTH; NARROW BANDS; ON FLOW; RESONANCE FREQUENCIES; SIGNAL EXTRACTION; WAVE FORMS; WIDE-BAND;

EID: 77956017647     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2010.06.002     Document Type: Article
Times cited : (5)

References (27)
  • 4
    • 0033980281 scopus 로고    scopus 로고
    • Pulse inversion imaging of liver blood flow: Improved method for characterizing focal masses with microbubble contrast
    • Burns P.N., Wilson S.R., Simpson D.H. Pulse inversion imaging of liver blood flow: Improved method for characterizing focal masses with microbubble contrast. Invest Radiol 2000, 35:58-71.
    • (2000) Invest Radiol , vol.35 , pp. 58-71
    • Burns, P.N.1    Wilson, S.R.2    Simpson, D.H.3
  • 8
    • 13644249895 scopus 로고    scopus 로고
    • Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power
    • Eckersley R.J., Chin C.T., Burns P.N. Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power. Ultrasound Med Biol 2005, 31:213-219.
    • (2005) Ultrasound Med Biol , vol.31 , pp. 213-219
    • Eckersley, R.J.1    Chin, C.T.2    Burns, P.N.3
  • 10
    • 0033727931 scopus 로고    scopus 로고
    • Influence of bubble size distribution on the echogenicity of ultrasound contrast agents: A study of SonoVue™
    • Gorce J., Arditi M., Schneider M. Influence of bubble size distribution on the echogenicity of ultrasound contrast agents: A study of SonoVue™. Invest Radiol 2000, 35:661-671.
    • (2000) Invest Radiol , vol.35 , pp. 661-671
    • Gorce, J.1    Arditi, M.2    Schneider, M.3
  • 12
    • 32444435115 scopus 로고    scopus 로고
    • Arbitrary waveform coded excitation using bipolar square wave pulsers in medical ultrasound
    • Huang S.W., Li P.C. Arbitrary waveform coded excitation using bipolar square wave pulsers in medical ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control 2006, 53:106-116.
    • (2006) IEEE Trans Ultrason Ferroelectr Freq Control , vol.53 , pp. 106-116
    • Huang, S.W.1    Li, P.C.2
  • 16
    • 54049109240 scopus 로고    scopus 로고
    • Using optical scattering to measure properties of ultrasound contrast agent shells
    • US Patent 0098232.
    • Matula T, Guan J. Using optical scattering to measure properties of ultrasound contrast agent shells. US Patent 0098232, 2007.
    • (2007)
    • Matula, T.1    Guan, J.2
  • 17
    • 0021428883 scopus 로고
    • Bubble size measurements using the nonlinear mixing of two frequencies
    • Newhouse V.L., Shankar P.M. Bubble size measurements using the nonlinear mixing of two frequencies. J Acoust Soc Am 1984, 75:1473-1477.
    • (1984) J Acoust Soc Am , vol.75 , pp. 1473-1477
    • Newhouse, V.L.1    Shankar, P.M.2
  • 18
    • 0026866582 scopus 로고
    • Coded excitation system for improving the penetration of real-time phased-array imaging systems
    • O'Donnell M. Coded excitation system for improving the penetration of real-time phased-array imaging systems. IEEE Trans Ultrason Ferroelectr Freq Control 1992, 39:341-351.
    • (1992) IEEE Trans Ultrason Ferroelectr Freq Control , vol.39 , pp. 341-351
    • O'Donnell, M.1
  • 19
    • 0024409983 scopus 로고
    • Contrast agents in diagnostic ultrasound
    • Ophir J., Parker K.J. Contrast agents in diagnostic ultrasound. Ultrasound Med Biol 1989, 15:319-333.
    • (1989) Ultrasound Med Biol , vol.15 , pp. 319-333
    • Ophir, J.1    Parker, K.J.2
  • 20
    • 0029988860 scopus 로고    scopus 로고
    • High-resolution bubble sizing through detection of the subharmonic response with a two-frequency excitation technique
    • Phelps A.D., Leighton T.G. High-resolution bubble sizing through detection of the subharmonic response with a two-frequency excitation technique. J Acoust Soc Amer 1996, 99:1985-1992.
    • (1996) J Acoust Soc Amer , vol.99 , pp. 1985-1992
    • Phelps, A.D.1    Leighton, T.G.2
  • 22
    • 0142007937 scopus 로고    scopus 로고
    • Pulse-inversion-based fundamental imaging for contrast detection
    • Shen C.C., Li P.C. Pulse-inversion-based fundamental imaging for contrast detection. IEEE Trans Ultrason Ferroelectr Freq Control 2003, 50:1124-1133.
    • (2003) IEEE Trans Ultrason Ferroelectr Freq Control , vol.50 , pp. 1124-1133
    • Shen, C.C.1    Li, P.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.