메뉴 건너뛰기




Volumn 25, Issue 2, 1999, Pages 275-283

Pressure dependence of subharmonic signals from contrast microbubbles

Author keywords

Blood pressure; Contrast agents; Harmonic signals; Microbubbles; Pressure estimation; Subharmonic signals; Ultrasound imaging

Indexed keywords

ACOUSTIC SIGNAL PROCESSING; BLOOD VESSELS; BUBBLES (IN FLUIDS); CARDIOVASCULAR SYSTEM; CONTRAST MEDIA; MEDICAL IMAGING; NONINVASIVE MEDICAL PROCEDURES;

EID: 0033084094     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(98)00163-X     Document Type: Article
Times cited : (217)

References (31)
  • 1
    • 0029932815 scopus 로고    scopus 로고
    • Effect of static pressure on acoustic transmittance of Albunex microbubble suspensions
    • Brayman A.A., Azadniv M., Miller M.W., Meltzer R.S. Effect of static pressure on acoustic transmittance of Albunex microbubble suspensions. J Acoust Soc Am. 99:1996;2403-2408.
    • (1996) J Acoust Soc Am , vol.99 , pp. 2403-2408
    • Brayman, A.A.1    Azadniv, M.2    Miller, M.W.3    Meltzer, R.S.4
  • 3
    • 0030171567 scopus 로고    scopus 로고
    • In vitro evaluation of acoustic properties of ultrasound contrast agents: Experimental set-up and signal processing
    • Cachard C., Bouakkaz A., Gimenez G. In vitro evaluation of acoustic properties of ultrasound contrast agents experimental set-up and signal processing . Ultrasonics. 34:1996;595-598.
    • (1996) Ultrasonics , vol.34 , pp. 595-598
    • Cachard, C.1    Bouakkaz, A.2    Gimenez, G.3
  • 5
    • 0026830293 scopus 로고
    • Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measurements
    • de Jong N., Hoff L., Skotland T., Bom N. Absorption and scatter of encapsulated gas filled microspheres theoretical considerations and some measurements . Ultrasonics. 30:1992;95-103.
    • (1992) Ultrasonics , vol.30 , pp. 95-103
    • De Jong, N.1    Hoff, L.2    Skotland, T.3    Bom, N.4
  • 7
    • 0030297084 scopus 로고    scopus 로고
    • Improvements in ultrasound contrast agents
    • de Jong N. Improvements in ultrasound contrast agents. IEEE Eng Med Biol Mag. 15:1996;72-82.
    • (1996) IEEE Eng Med Biol Mag , vol.15 , pp. 72-82
    • De Jong, N.1
  • 8
    • 0014574831 scopus 로고
    • Generation of subharmonics of order one-half by bubble in a sound field
    • Eller A., Flynn H.G. Generation of subharmonics of order one-half by bubble in a sound field. J Acoust Soc Am. 46:1969;722-727.
    • (1969) J Acoust Soc Am , vol.46 , pp. 722-727
    • Eller, A.1    Flynn, H.G.2
  • 11
    • 0029239771 scopus 로고
    • Effect of pressure on echocardio-graphic videodensity from sonicated albumin: An in vitro model
    • Gottlieb S., Ernst A., Meltzer R.S. Effect of pressure on echocardio-graphic videodensity from sonicated albumin An in vitro model . J Ultrasound Med. 14:1995;101-108.
    • (1995) J Ultrasound Med , vol.14 , pp. 101-108
    • Gottlieb, S.1    Ernst, A.2    Meltzer, R.S.3
  • 12
    • 0016925396 scopus 로고
    • Numerical investigation of nonlinear oscillations of gas bubble in liquids
    • Lauterborne W. Numerical investigation of nonlinear oscillations of gas bubble in liquids. J Acoust Soc Am. 59:1976;283-293.
    • (1976) J Acoust Soc Am , vol.59 , pp. 283-293
    • Lauterborne, W.1
  • 13
    • 0026189724 scopus 로고
    • Acoustic bubble sizing by combination of subharmonic emission with imaging frequency
    • Leighton T.G., Lingard R.J., Walton A.J., Field J.E. Acoustic bubble sizing by combination of subharmonic emission with imaging frequency. Ultrasonics. 29:1991;319-323.
    • (1991) Ultrasonics , vol.29 , pp. 319-323
    • Leighton, T.G.1    Lingard, R.J.2    Walton, A.J.3    Field, J.E.4
  • 15
    • 0029867509 scopus 로고    scopus 로고
    • Experimental observation of subharmonic oscillations in infoson bubbles
    • Lotsberg O., Hovem J.M., Aksum B. Experimental observation of subharmonic oscillations in infoson bubbles. J Acoust Soc Am. 99:1996;1366-1369.
    • (1996) J Acoust Soc Am , vol.99 , pp. 1366-1369
    • Lotsberg, O.1    Hovem, J.M.2    Aksum, B.3
  • 16
    • 0029556001 scopus 로고    scopus 로고
    • Contrast agents in ultrasound
    • Needleman L., Forsberg F. Contrast agents in ultrasound. Ultrasound Q. 13:1996;121-138.
    • (1996) Ultrasound Q , vol.13 , pp. 121-138
    • Needleman, L.1    Forsberg, F.2
  • 17
    • 0014574534 scopus 로고
    • Subharmonic and other low-frequency emission from bubbles in sound-irradiated liquids
    • Neppiras E.A. Subharmonic and other low-frequency emission from bubbles in sound-irradiated liquids. J Acoust Soc Am. 46:1968;587-601.
    • (1968) J Acoust Soc Am , vol.46 , pp. 587-601
    • Neppiras, E.A.1
  • 18
    • 0024409983 scopus 로고
    • Contrast agents in diagnostic ultrasound
    • Ophir J., Parker K.J. Contrast agents in diagnostic ultrasound. Ultrasound Med Biol. 15:1989;319-325.
    • (1989) Ultrasound Med Biol , vol.15 , pp. 319-325
    • Ophir, J.1    Parker, K.J.2
  • 19
    • 0029988860 scopus 로고    scopus 로고
    • High-resolution bubble sizing through detection of the subharmonic response with a two-frequency excitation technique
    • Phelps A.D., Leighton T.G. High-resolution bubble sizing through detection of the subharmonic response with a two-frequency excitation technique. J Acoust Soc Am. 99:1996;1985-1992.
    • (1996) J Acoust Soc Am , vol.99 , pp. 1985-1992
    • Phelps, A.D.1    Leighton, T.G.2
  • 20
    • 0008876869 scopus 로고
    • Application of the subharmonic threshold to the measurement of the damping of oscillating gas bubbles
    • Prosperetti A. Application of the subharmonic threshold to the measurement of the damping of oscillating gas bubbles. J Acoust Soc Am. 61:1977;11-16.
    • (1977) J Acoust Soc Am , vol.61 , pp. 11-16
    • Prosperetti, A.1
  • 22
    • 0001903878 scopus 로고    scopus 로고
    • Galactose-based echo-enhancing agents
    • B.B. Goldberg. London: Martin Dunitz Ltd
    • Schlief R. Galactose-based echo-enhancing agents. Goldberg B.B. Ultrasound contrast agents. 1997;75-82 Martin Dunitz Ltd, London.
    • (1997) Ultrasound Contrast Agents , pp. 75-82
    • Schlief, R.1
  • 23
    • 0027496845 scopus 로고
    • Second harmonic ultrasound blood perfusion measurement
    • Schrope B.A., Newhouse V.L. Second harmonic ultrasound blood perfusion measurement. Ultrasound Med Biol. 19:1993;567-579.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 567-579
    • Schrope, B.A.1    Newhouse, V.L.2
  • 24
    • 0026535688 scopus 로고
    • Simulated capillary blood flow measurement using a nonlinear ultrasonic contrast agent
    • Schrope B.A., Newhouse V.L., Uhlendorf V. Simulated capillary blood flow measurement using a nonlinear ultrasonic contrast agent. Ultrasonic Imaging. 14:1992;134-158.
    • (1992) Ultrasonic Imaging , vol.14 , pp. 134-158
    • Schrope, B.A.1    Newhouse, V.L.2    Uhlendorf, V.3
  • 25
    • 0032033485 scopus 로고    scopus 로고
    • Advantages of subharmonic over second harmonic backscatter for contrast-to-tissue echo enhancement
    • Shankar P.M., Krishna P.D., Newhouse V.L. Advantages of subharmonic over second harmonic backscatter for contrast-to-tissue echo enhancement. Ultrasound Med Biol. 24:1998;395-399.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 395-399
    • Shankar, P.M.1    Krishna, P.D.2    Newhouse, V.L.3
  • 26
    • 0025612337 scopus 로고
    • Intravenous contrast echocardiography with use of sonicated albumin in humans: Systolic disappearance of left ventricular contrast after transpulmonary transmission
    • Shapiro J.S., Reisner S.A., Lichtenberg G.S., Meltzer R.S. Intravenous contrast echocardiography with use of sonicated albumin in humans systolic disappearance of left ventricular contrast after transpulmonary transmission . J Am Coll Cardiol. 7:1990;1603-1607.
    • (1990) J Am Coll Cardiol , vol.7 , pp. 1603-1607
    • Shapiro, J.S.1    Reisner, S.A.2    Lichtenberg, G.S.3    Meltzer, R.S.4
  • 27
    • 0013199954 scopus 로고    scopus 로고
    • Subharmonic imaging with gas-filled microbubbles
    • (Abstr.)
    • Shi W.T., Forsberg F., Goldberg B.B. Subharmonic imaging with gas-filled microbubbles. (Abstr.) J Acoust Soc Am. 101:1997;3139.
    • (1997) J Acoust Soc Am , vol.101 , pp. 3139
    • Shi, W.T.1    Forsberg, F.2    Goldberg, B.B.3
  • 29
    • 0031347251 scopus 로고    scopus 로고
    • Spectral broadening in conventional and harmonic doppler measurements with gaseous contrast agents
    • Shi WT, Forsberg F, Oung H. Spectral broadening in conventional and harmonic doppler measurements with gaseous contrast agents. Proc 1997 IEEE Ultrason Symp 1997:1575-1578.
    • (1997) Proc 1997 IEEE Ultrason Symp , pp. 1575-1578
    • Shi, W.T.1    Forsberg, F.2    Oung, H.3
  • 30
    • 0344626986 scopus 로고    scopus 로고
    • Effect of ambient pressure change on subharmonic response of microbubbles
    • (Abstr.)
    • Shi W.T., Raichlen J.S., Forsberg F., Goldberg B.B. Effect of ambient pressure change on subharmonic response of microbubbles. (Abstr.) J Ultrasound Med. 17:1998;S55.
    • (1998) J Ultrasound Med , vol.17 , pp. 55
    • Shi, W.T.1    Raichlen, J.S.2    Forsberg, F.3    Goldberg, B.B.4
  • 31
    • 0345057412 scopus 로고    scopus 로고
    • Surfactant-stabilized microbubble mixtures, process for preparing and methods of using the same. 1993. U.S. Patent 5,352,436
    • Wheatley MA, Peng S, Singhal S, Goldberg BB. Surfactant-stabilized microbubble mixtures, process for preparing and methods of using the same. 1993. U.S. Patent 5,352,436.
    • Wheatley, M.A.1    Peng, S.2    Singhal, S.3    Goldberg, B.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.