메뉴 건너뛰기




Volumn 3, Issue 3, 2010, Pages 249-256

Comparison of the long-term safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts

Author keywords

Angioplasty; Saphenous vein graft; Stent thrombosis; Stents

Indexed keywords

'TAXUS'; CYPHER; PACLITAXEL; RAPAMYCIN; UNCLASSIFIED DRUG;

EID: 77955890949     PISSN: 19417640     EISSN: 19417632     Source Type: Journal    
DOI: 10.1161/CIRCINTERVENTIONS.109.929042     Document Type: Article
Times cited : (17)

References (32)
  • 3
    • 0029089448 scopus 로고
    • Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: The multicenter U.S. Palmaz-Schatz stent experience
    • The Palmaz-Schatz Stent Study Group
    • Wong SC, Baim DS, Schatz RA, Teirstein PS, King SB III, Curry RC Jr, Heuser RR, Ellis SG, Cleman MW, Overlie P. Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: the multicenter U.S. Palmaz-Schatz stent experience. The Palmaz-Schatz Stent Study Group. J Am Coll Cardiol. 1995;26:704-712.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 704-712
    • Wong, S.C.1    Baim, D.S.2    Schatz, R.A.3    Teirstein, P.S.4    King III, S.B.5    Curry Jr., R.C.6    Heuser, R.R.7    Ellis, S.G.8    Cleman, M.W.9    Overlie, P.10
  • 5
    • 0037422604 scopus 로고    scopus 로고
    • TAXUS I: Six-and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions
    • Grube E, Silber S, Hauptmann KE, Mueller R, Buellesfeld L, Gerckens U, Russell ME. TAXUS I: six-and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation. 2003;107:38-42.
    • (2003) Circulation , vol.107 , pp. 38-42
    • Grube, E.1    Silber, S.2    Hauptmann, K.E.3    Mueller, R.4    Buellesfeld, L.5    Gerckens, U.6    Russell, M.E.7
  • 6
    • 0037030658 scopus 로고    scopus 로고
    • Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • RAVEL Study Group
    • Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban HE, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R; RAVEL Study Group. Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3    Fajadet, J.4    Ban, H.E.5    Perin, M.6    Colombo, A.7    Schuler, G.8    Barragan, P.9    Guagliumi, G.10    Molnar, F.11    Falotico, R.12
  • 8
    • 34447120247 scopus 로고    scopus 로고
    • Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts: Results from the randomized DELAYED RRISC Trial
    • DELAYED RRISC (Death and Events at Long-term follow-up AnalYsis: Extended Duration of the Reduction of Restenosis In Saphenous vein grafts with Cypher stent) Investigators
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Van den Branden F, Van Langenhove G; DELAYED RRISC (Death and Events at Long-term follow-up AnalYsis: Extended Duration of the Reduction of Restenosis In Saphenous vein grafts with Cypher stent) Investigators. Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts: results from the randomized DELAYED RRISC Trial. J Am Coll Cardiol. 2007;50: 261-267.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 261-267
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    Van Den Heuvel, P.4    Convens, C.5    Van Den Branden, F.6    Van Langenhove, G.7
  • 9
    • 36548998846 scopus 로고    scopus 로고
    • Universal definition of myocardial infarction
    • Joint ESC/ACCF/AHA/WHF Task Force for the Redefinition of Myocardial Infarction, Jaffe AS, Apple FS, Galvani M, Katus HA, Newby LK, Ravkilde J, Chaitman B, Clemmensen PM, Dellborg M, Hod H, Porela P, Underwood R, Bax JJ, Beller GA, Bonow R, Van der Wall EE, Bassand JP, Wijns W, Ferguson TB, Steg PG, Uretsky BF, Williams DO, Armstrong PW, Antman EM, Fox KA, Hamm CW, Ohman EM, Simoons ML, Poole-Wilson PA, Gurfinkel EP, Lopez-Sendon JL, Pais P, Mendis S, Zhu JR, Wallentin LC, Fernandez-Aviles F, Fox KM, Parkhomenko AN, Priori SG, Tendera M, Voipio-Pulkki LM, Vahanian A, Camm AJ, De Caterina R, Dean V, Dickstein K, Filippatos G, Funck-Brentano C, Hellemans I, Kristensen SD, McGregor K, Sechtem U, Silber S, Widimsky P, Zamorano JL, Morais J, Brener S, Harrington R, Morrow D, Lim M, Martinez-Rios MA, Steinhubl S, Levine GN, Gibler WB, Goff D, Tubaro M, Dudek D, Al-Attar N
    • Thygesen K, Alpert JS, White HD; Joint ESC/ACCF/AHA/WHF Task Force for the Redefinition of Myocardial Infarction, Jaffe AS, Apple FS, Galvani M, Katus HA, Newby LK, Ravkilde J, Chaitman B, Clemmensen PM, Dellborg M, Hod H, Porela P, Underwood R, Bax JJ, Beller GA, Bonow R, Van der Wall EE, Bassand JP, Wijns W, Ferguson TB, Steg PG, Uretsky BF, Williams DO, Armstrong PW, Antman EM, Fox KA, Hamm CW, Ohman EM, Simoons ML, Poole-Wilson PA, Gurfinkel EP, Lopez-Sendon JL, Pais P, Mendis S, Zhu JR, Wallentin LC, Fernandez-Aviles F, Fox KM, Parkhomenko AN, Priori SG, Tendera M, Voipio-Pulkki LM, Vahanian A, Camm AJ, De Caterina R, Dean V, Dickstein K, Filippatos G, Funck-Brentano C, Hellemans I, Kristensen SD, McGregor K, Sechtem U, Silber S, Widimsky P, Zamorano JL, Morais J, Brener S, Harrington R, Morrow D, Lim M, Martinez-Rios MA, Steinhubl S, Levine GN, Gibler WB, Goff D, Tubaro M, Dudek D, Al-Attar N. Universal definition of myocardial infarction. Circulation. 2007;116: 2634-2653.
    • (2007) Circulation , vol.116 , pp. 2634-2653
    • Thygesen, K.1    Alpert, J.S.2    White, H.D.3
  • 11
    • 0037116577 scopus 로고    scopus 로고
    • Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation
    • Lansky AJ, Dangas G, Mehran R, Desai KJ, Mintz GS, Wu H, Fahy M, Stone GW, Waksman R, Leon MB. Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation. J Am Coll Cardiol. 2002;39:274-280.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 274-280
    • Lansky, A.J.1    Dangas, G.2    Mehran, R.3    Desai, K.J.4    Mintz, G.S.5    Wu, H.6    Fahy, M.7    Stone, G.W.8    Waksman, R.9    Leon, M.B.10
  • 14
    • 0642279547 scopus 로고    scopus 로고
    • A method for checking regression models in survival analysis based on the risk score
    • Gronnesby JK, Borgan O. A method for checking regression models in survival analysis based on the risk score. Lifetime Data Anal. 1996;2: 315-328.
    • (1996) Lifetime Data Anal , vol.2 , pp. 315-328
    • Gronnesby, J.K.1    Borgan, O.2
  • 15
    • 0031605154 scopus 로고    scopus 로고
    • A simplified method of calculating an overall goodness-of-fit test for the Cox proportional hazards model
    • May S, Hosmer DW. A simplified method of calculating an overall goodness-of-fit test for the Cox proportional hazards model. Lifetime Data Anal. 1998;4:109-120.
    • (1998) Lifetime Data Anal , vol.4 , pp. 109-120
    • May, S.1    Hosmer, D.W.2
  • 16
    • 3543135271 scopus 로고    scopus 로고
    • Propensity score methods for bias reduction in the comparison of a treatment to a non-randomized control group
    • D'Agostino RB Jr. Propensity score methods for bias reduction in the comparison of a treatment to a non-randomized control group. Stat Med. 1998;17:2265-2281.
    • (1998) Stat Med , vol.17 , pp. 2265-2281
    • D'Agostino Jr., R.B.1
  • 17
    • 0030862072 scopus 로고    scopus 로고
    • Estimating causal effects from large data sets using propensity scores
    • Rubin DB. Estimating causal effects from large data sets using propensity scores. Ann Intern Med. 1997;127:757-763.
    • (1997) Ann Intern Med , vol.127 , pp. 757-763
    • Rubin, D.B.1
  • 18
    • 0032560648 scopus 로고    scopus 로고
    • Interlesion dependence of the risk for restenosis in patients with coronary stent placement in in multiple lesions
    • Kastrati A, Schomig A, Elezi S, Schuhlen H, Wilhelm M, Dirschinger J. Interlesion dependence of the risk for restenosis in patients with coronary stent placement in in multiple lesions. Circulation. 1998;97: 2396-2401.
    • (1998) Circulation , vol.97 , pp. 2396-2401
    • Kastrati, A.1    Schomig, A.2    Elezi, S.3    Schuhlen, H.4    Wilhelm, M.5    Dirschinger, J.6
  • 19
    • 0031006441 scopus 로고    scopus 로고
    • A comparison of goodness-of-fit tests for the logistic regression model
    • Hosmer DW, Hosmer T, Le Cessie S, Lemeshow S. A comparison of goodness-of-fit tests for the logistic regression model. Stat Med. 1997; 16:965-980.
    • (1997) Stat Med , vol.16 , pp. 965-980
    • Hosmer, D.W.1    Hosmer, T.2    Le Cessie, S.3    Lemeshow, S.4
  • 21
    • 34147197569 scopus 로고    scopus 로고
    • Implantation of paclitaxel-eluting stents in saphenous vein grafts: Clinical and angiographic follow-up results from a multicentre study
    • Hoffmann R, Pohl T, Koster R, Blindt R, Boeckstegers P, Heitzer T. Implantation of paclitaxel-eluting stents in saphenous vein grafts: clinical and angiographic follow-up results from a multicentre study. Heart. 2007;93:331-334.
    • (2007) Heart , vol.93 , pp. 331-334
    • Hoffmann, R.1    Pohl, T.2    Koster, R.3    Blindt, R.4    Boeckstegers, P.5    Heitzer, T.6
  • 23
    • 36549008097 scopus 로고    scopus 로고
    • Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease
    • Minutello RM, Bhagan S, Sharma A, Slotwiner AJ, Feldman DN, Cuomo LJ, Wong SC. Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease. J Interv Cardiol. 2007;20:458-465.
    • (2007) J Interv Cardiol , vol.20 , pp. 458-465
    • Minutello, R.M.1    Bhagan, S.2    Sharma, A.3    Slotwiner, A.J.4    Feldman, D.N.5    Cuomo, L.J.6    Wong, S.C.7
  • 26
    • 34848856445 scopus 로고    scopus 로고
    • Utility of sirolimuseluting Cypher stents to reduce 12-month target vessel revascularization in saphenous vein graft stenoses: Results of a multicenter 350-patient case-control study
    • Ellis SG, Kandzari D, Kereiakes DJ, Pichard A, Huber K, Resnic F, Yakubov S, Callahan K, Borgman M, Cohen SA. Utility of sirolimuseluting Cypher stents to reduce 12-month target vessel revascularization in saphenous vein graft stenoses: results of a multicenter 350-patient case-control study. J Invasive Cardiol. 2007;19:404-409.
    • (2007) J Invasive Cardiol , vol.19 , pp. 404-409
    • Ellis, S.G.1    Kandzari, D.2    Kereiakes, D.J.3    Pichard, A.4    Huber, K.5    Resnic, F.6    Yakubov, S.7    Callahan, K.8    Borgman, M.9    Cohen, S.A.10
  • 27
    • 47549096848 scopus 로고    scopus 로고
    • Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts
    • Gioia G, Benassi A, Mohendra R, Chowdhury K, Masood I, Matthai W. Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts. Catheter Cardiovasc Interv. 2008;72:13-20.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 13-20
    • Gioia, G.1    Benassi, A.2    Mohendra, R.3    Chowdhury, K.4    Masood, I.5    Matthai, W.6
  • 30
    • 33846927284 scopus 로고    scopus 로고
    • Comparison of the slow-release polymer-based paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions
    • Wohrle J, Nusser T, Kestler HA, Kochs M, Hombach V. Comparison of the slow-release polymer-based paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions. Clin Res Cardiol. 2007;96:70-76.
    • (2007) Clin Res Cardiol , vol.96 , pp. 70-76
    • Wohrle, J.1    Nusser, T.2    Kestler, H.A.3    Kochs, M.4    Hombach, V.5
  • 32
    • 33845410666 scopus 로고    scopus 로고
    • Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts: Six-month angiographic, intravascular ultrasound, and clinical follow-up of the RRISC Trial
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Bruining N, Van den Branden F, Van Langenhove G. Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts: six-month angiographic, intravascular ultrasound, and clinical follow-up of the RRISC Trial. J Am Coll Cardiol. 2006;48:2423-2431.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2423-2431
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    Van Den Heuvel, P.4    Convens, C.5    Bruining, N.6    Van Den Branden, F.7    Van Langenhove, G.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.