메뉴 건너뛰기




Volumn 57, Issue 9, 2010, Pages 2313-2321

Contribution of oxygen reduction to charge injection on platinum and sputtered iridium oxide neural stimulation electrodes

Author keywords

Electrodes; iridium oxide; neural stimulation; oxygen reduction; platinum

Indexed keywords

CHARGE CAPACITIES; CURRENT PULSING; IN-VIVO; IRIDIUM OXIDE; NEURAL STIMULATIONS; OXYGEN REDUCTION; PHYSIOLOGICAL SALINE; PLATINUM ELECTRODES; SPUTTERED IRIDIUM OXIDE; SURFACE AREA; TOTAL CHARGE; TRANSIENT MEASUREMENT;

EID: 77955880538     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2010.2050690     Document Type: Article
Times cited : (33)

References (23)
  • 1
    • 0028336243 scopus 로고
    • The role of oxygen reduction in electrical stimulation of neural tissue
    • S. L. Morton, M. L. Daroux, and J. T. Mortimer, "The role of oxygen reduction in electrical stimulation of neural tissue," J. Electrochem. Soc., vol.141, pp. 122-130, 1994.
    • (1994) J. Electrochem. Soc. , vol.141 , pp. 122-130
    • Morton, S.L.1    Daroux, M.L.2    Mortimer, J.T.3
  • 2
    • 60549105071 scopus 로고    scopus 로고
    • Flexible nerve stimulation electrode with iridium oxide sputtered on liquid crystal polymer
    • Jan.
    • K. Wang, C.-C. Liu, and D. M. Durand, "Flexible nerve stimulation electrode with iridium oxide sputtered on liquid crystal polymer," IEEE Trans. Biomed. Eng., vol.56, no.1, pp. 6-14, Jan. 2009.
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , Issue.1 , pp. 6-14
    • Wang, K.1    Liu, C.-C.2    Durand, D.M.3
  • 4
    • 0346124147 scopus 로고    scopus 로고
    • Plasmaenhanced chemical vapor deposited (PECVD) silicon carbide as an implantable dielectric coating
    • S. F. Cogan, D. J. Edell, A. A. Guzelian, Y.-P. Liu, and R. Edell, "Plasmaenhanced chemical vapor deposited (PECVD) silicon carbide as an implantable dielectric coating," J. Biomed. Matls. Res., vol.67A, pp. 856-867, 2003.
    • (2003) J. Biomed. Matls. Res. , vol.67 A , pp. 856-867
    • Cogan, S.F.1    Edell, D.J.2    Guzelian, A.A.3    Liu, Y.-P.4    Edell, R.5
  • 5
    • 34748924121 scopus 로고    scopus 로고
    • Characterization of a-SiC(x):H thin films as an encapsulation material for integrated silicon based neural interface devices
    • J. M. Hsu, P. Tathireddy, L. Rieth, R. A. Normann, and F. Solzbacher, "Characterization of a-SiC(x):H thin films as an encapsulation material for integrated silicon based neural interface devices," Thin Solid Films, vol.516, pp. 34-41, 2007.
    • (2007) Thin Solid Films , vol.516 , pp. 34-41
    • Hsu, J.M.1    Tathireddy, P.2    Rieth, L.3    Normann, R.A.4    Solzbacher, F.5
  • 6
    • 0026205082 scopus 로고
    • A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
    • Aug.
    • P.K. Campbell, K. E. Jones, R. J. Huber, K.W. Horch, and R.A.Normann, "A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array," IEEE Trans. Biomed. Eng., vol.38, no.8, pp. 758-768, Aug. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.8 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 7
    • 0031106324 scopus 로고    scopus 로고
    • The Utah intracortical Electrode Array: A recording structure for potential brain-computer interfaces
    • E.M. Maynard,C. T.Nordhausen, and R. A. Normann, "The Utah intracortical Electrode Array: A recording structure for potential brain-computer interfaces," Electroencephalogr. Clin. Neurophysiol., vol.102, pp. 228-239, 1997.
    • (1997) Electroencephalogr. Clin. Neurophysiol. , vol.102 , pp. 228-239
    • Maynard, E.M.1    Nordhausen, C.T.2    Normann, R.A.3
  • 8
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulation and recording electrodes
    • S. F. Cogan, "Neural stimulation and recording electrodes," Annu. Rev. Biomed. Eng., vol.10, pp. 275-309, 2008.
    • (2008) Annu. Rev. Biomed. Eng. , vol.10 , pp. 275-309
    • Cogan, S.F.1
  • 10
    • 26844582938 scopus 로고    scopus 로고
    • In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes
    • Sep.
    • S. F. Cogan, P. R. Troyk, J. Ehrlich, and T. D. Plante, "In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes," IEEE Trans. Biomed. Eng., vol.52, no.9, pp. 1612-1614, Sep. 2005.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.9 , pp. 1612-1614
    • Cogan, S.F.1    Troyk, P.R.2    Ehrlich, J.3    Plante, T.D.4
  • 11
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • D. R. Merrill, M. Bikson, and J. G. R. Jefferys, "Electrical stimulation of excitable tissue: Design of efficacious and safe protocols," J. Neurosci. Methods., vol.141, pp. 171-198, 2005.
    • (2005) J. Neurosci. Methods. , vol.141 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.R.3
  • 12
    • 75649150767 scopus 로고    scopus 로고
    • Structural and electrochemical features of 3D nanoporous platinum electrodes
    • S. Park, Y. J. Song, J.-H. Han, H. Boo, and T. D. Chung, "Structural and electrochemical features of 3D nanoporous platinum electrodes," Electrochim. Acta, vol.55, pp. 2029-2035, 2010.
    • (2010) Electrochim. Acta , vol.55 , pp. 2029-2035
    • Park, S.1    Song, Y.J.2    Han, J.-H.3    Boo, H.4    Chung, T.D.5
  • 13
    • 0025913227 scopus 로고
    • Oxygen in mammalian tissue: Methods of measurement and affinities of various reactions
    • J. M. Vanderkooi, M. Erecínska, and I. A. Silver, "Oxygen in mammalian tissue: Methods of measurement and affinities of various reactions," Amer. J. Physiol., vol.260, no.6 pt. 1, pp. C1131-C1150, 1991.
    • (1991) Amer. J. Physiol. , vol.260 , Issue.6 PART 1
    • Vanderkooi, J.M.1    Erecínska, M.2    Silver, I.A.3
  • 14
    • 34447504911 scopus 로고    scopus 로고
    • Brain tissue oxygen concentration measurements
    • O. Ndubuizu and J. C. Lamanna, "Brain tissue oxygen concentration measurements," Antioxid. Redox Signal., vol.9, pp. 1207-1219, 2007.
    • (2007) Antioxid. Redox Signal. , vol.9 , pp. 1207-1219
    • Ndubuizu, O.1    Lamanna, J.C.2
  • 15
    • 34447526577 scopus 로고    scopus 로고
    • Measurements of oxygen in vivo: Overview and perspectives on methods to measure oxygen within cells and tissues
    • R. Springett and H. M. Swartz, "Measurements of oxygen in vivo: Overview and perspectives on methods to measure oxygen within cells and tissues," Antioxid. Redox Signal., vol.9, pp. 1295-1301, 2007.
    • (2007) Antioxid. Redox Signal. , vol.9 , pp. 1295-1301
    • Springett, R.1    Swartz, H.M.2
  • 16
    • 0025454635 scopus 로고
    • Partial pressure of oxygen in brain and peripheral nerve during damaging electrical stimulation
    • D. B. McCreery,W. F. Agnew, L. A. Bullara, and T. G. Yuen, "Partial pressure of oxygen in brain and peripheral nerve during damaging electrical stimulation," J. Biomed. Eng., vol.12, pp. 309-315, 1990.
    • (1990) J. Biomed. Eng. , vol.12 , pp. 309-315
    • McCreery, D.B.1    Agnew, W.F.2    Bullara, L.A.3    Yuen, T.G.4
  • 18
    • 0001862329 scopus 로고    scopus 로고
    • Recent advances in the kinetics of oxygen reduction
    • J. Lipkowski and P. N. Ross, Eds. New York: Wiley-VCH
    • R. Adžíc, "Recent advances in the kinetics of oxygen reduction," in Electrocatalysis, J. Lipkowski and P. N. Ross, Eds. New York: Wiley-VCH, 1998, pp. 197-242.
    • (1998) Electrocatalysis , pp. 197-242
    • Adžíc, R.1
  • 19
    • 0022361687 scopus 로고
    • Calculations of the pH changes produced in body tissue by a spherical stimulation electrode
    • C. L. Ballestrasse, R. T. Ruggeri, and T. R. Beck, "Calculations of the pH changes produced in body tissue by a spherical stimulation electrode," Ann. Biomed. Eng., vol.13, pp. 405-424, 1985.
    • (1985) Ann. Biomed. Eng. , vol.13 , pp. 405-424
    • Ballestrasse, C.L.1    Ruggeri, R.T.2    Beck, T.R.3
  • 20
    • 33748373872 scopus 로고    scopus 로고
    • Tissue reaction to electrodes: The problem of safe and effective stimulation of neural tissue
    • K. W. Horch and G. S. Dhillon, Eds. Singapore: World Scientific
    • D. B. McCreery, "Tissue reaction to electrodes: The problem of safe and effective stimulation of neural tissue," in Neuroprosthetics Theory and Practice, K. W. Horch and G. S. Dhillon, Eds. Singapore: World Scientific, 2004.
    • (2004) Neuroprosthetics Theory and Practice
    • McCreery, D.B.1
  • 22
    • 23644450358 scopus 로고    scopus 로고
    • Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
    • R. Biran, D. C. Martin, and P. A. Tresco, "Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays," Exp. Neurol., vol.195, pp. 115-126, 2005.
    • (2005) Exp. Neurol. , vol.195 , pp. 115-126
    • Biran, R.1    Martin, D.C.2    Tresco, P.A.3
  • 23
    • 0347927495 scopus 로고    scopus 로고
    • In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
    • Dec.
    • J. D. Weiland, D. J. Anderson, and M. S. Humayun, "In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes," IEEE Trans. Biomed. Eng., vol.49, no.12, pp. 1574-1579, Dec. 2002.
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , Issue.12 , pp. 1574-1579
    • Weiland, J.D.1    Anderson, D.J.2    Humayun, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.