메뉴 건너뛰기




Volumn , Issue , 2010, Pages 3654-3659

Miniaturized force-indentation depth sensor for tissue abnormality identification during laparoscopic surgery

Author keywords

[No Author keywords available]

Indexed keywords

FIBER-OPTICAL; INDENTATION DEPTH; LAPAROSCOPIC SURGERY; MINIMALLY INVASIVE SURGERY; SOFT TISSUE; SPHERICAL INDENTERS; TISSUE ABNORMALITIES; TISSUE REACTIONS; TISSUE SURFACE;

EID: 77955832662     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2010.5509440     Document Type: Conference Paper
Times cited : (12)

References (17)
  • 1
    • 0037001978 scopus 로고    scopus 로고
    • Early experience with telemanipulative abdominal and cardiac surgery with the ZeusTM Robotic System
    • Uranues, S., et al. "Early experience with telemanipulative abdominal and cardiac surgery with the ZeusTM Robotic System", Euro. Surg., Vol. 34, pp. 190-193,2002
    • (2002) Euro. Surg. , vol.34 , pp. 190-193
    • Uranues, S.1
  • 3
    • 0033301912 scopus 로고    scopus 로고
    • Endoscopic coronary artery bypass graft (ECABG) procedure with robotic assistance
    • Tabaie, H. A., et al. "Endoscopic coronary artery bypass graft (ECABG) procedure with robotic assistance" ,The Heart Surgery Forum, Vol. 2, pp. 310-317, 1999.
    • (1999) The Heart Surgery Forum , vol.2 , pp. 310-317
    • Tabaie, H.A.1
  • 5
    • 77950363076 scopus 로고    scopus 로고
    • Rolling Indentation for Tissue Abnormality Localization during Minimally Invasive Surgery
    • H. Liu, D. Noonan, L. Seneviratne, P. Dasgupta, K. Althoefer, Rolling Indentation for Tissue Abnormality Localization during Minimally Invasive Surgery, IEEE Trans. on Biomedical Eng., 57(2). 2010 pp. 404-414.
    • (2010) IEEE Trans. on Biomedical Eng. , vol.57 , Issue.2 , pp. 404-414
    • Liu, H.1    Noonan, D.2    Seneviratne, L.3    Dasgupta, P.4    Althoefer, K.5
  • 6
    • 61849181169 scopus 로고    scopus 로고
    • The Rolling Approach for Soft Tissue modeling and Mechanical Imaging during robot-assisted Minimally Invasive Surgery
    • Liu, H., et al. "The Rolling Approach for Soft Tissue modeling and Mechanical Imaging during robot-assisted Minimally Invasive Surgery" ,Proc. IEEE Int. Conf. Robot. Autom. ,pp. 846-850, 2008.
    • (2008) Proc. IEEE Int. Conf. Robot. Autom. , pp. 846-850
    • Liu, H.1
  • 7
    • 38049056624 scopus 로고    scopus 로고
    • Major mandibular surgical procedures as an indication for intraoperative imaging
    • Pohlenz, P, et al. "Major mandibular surgical procedures as an indication for intraoperative imaging", J Oral Maxillofac Surg, Vol. 66, pp. 324-329, 2008
    • (2008) J Oral Maxillofac Surg , vol.66 , pp. 324-329
    • Pohlenz, P.1
  • 8
    • 45149121382 scopus 로고    scopus 로고
    • Use of the mini C-arm for wrist fractures - Establishing a diagnostic reference level
    • Love, G. J., Pillai, A. and Gibson, S. "Use of the mini C-arm for wrist fractures - establishing a diagnostic reference level", Radiat Prot Dosimetry, Vol. 128, pp. 309-311,2008
    • (2008) Radiat Prot Dosimetry , vol.128 , pp. 309-311
    • Love, G.J.1    Pillai, A.2    Gibson, S.3
  • 10
    • 84883841755 scopus 로고    scopus 로고
    • Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm
    • Jain, A, et al. " Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm", Int Conf Med Image Comput Comput Assist Interv., Vol. 10(Pt 2), pp. 9-17,2007.
    • (2007) Int Conf Med Image Comput Comput Assist Interv. , vol.10 , Issue.PART 2 , pp. 9-17
    • Jain, A.1
  • 11
    • 0033898934 scopus 로고    scopus 로고
    • Real-time Structured Light Depth Extraction
    • Keller, K. and Ackerman, J. "Real-time Structured Light Depth Extraction", SPIE proceedings. pp. 11-18, 2000.
    • (2000) SPIE Proceedings , pp. 11-18
    • Keller, K.1    Ackerman, J.2
  • 13
    • 30344438510 scopus 로고    scopus 로고
    • A practical approach towards accurate dense 3D depth recovery for robotic laparoscopic surgery
    • Stoyanov, D, Darzi, A and Yang, G.Z. "A practical approach towards accurate dense 3D depth recovery for robotic laparoscopic surgery", Comput Aided Surg, Vol. 10, pp. 199-208, 2005.
    • (2005) Comput Aided Surg , vol.10 , pp. 199-208
    • Stoyanov, D.1    Darzi, A.2    Yang, G.Z.3
  • 16
    • 51649123558 scopus 로고    scopus 로고
    • Optical fiber sensor for soft tissue investigation during minimally invasive surgery
    • Puangmali, P., et al., Optical fiber sensor for soft tissue investigation during minimally invasive surgery. 2008. Proc. IEEE Int. Conf. Robot. Autom. pp. 2934-2939.
    • 2008. Proc. IEEE Int. Conf. Robot. Autom. , pp. 2934-2939
    • Puangmali, P.1
  • 17
    • 33645975467 scopus 로고    scopus 로고
    • Simulation and experimental studies of inclined two fiber displacement sensor
    • Buchade, P.B. and Shaligram, A.D. Simulation and experimental studies of inclined two fiber displacement sensor. 2006, Sensors and Actuators A , Vol. 128, pp. 312-316.
    • 2006, Sensors and Actuators A , vol.128 , pp. 312-316
    • Buchade, P.B.1    Shaligram, A.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.