메뉴 건너뛰기




Volumn , Issue , 2010, Pages 2056-2061

Robotic delivery of complex radiation volumes for small animal research

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL MODEL; CLINICAL TRANSLATION; COMPLETE SYSTEM; COMPLEX SHAPES; CONEBEAM CT; DESIGN AND OPERATIONS; DOSE IRRADIATION; FOCUSED BEAMS; HIGH DOSE; IMAGE GUIDANCES; MICROENVIRONMENTS; MULTI-DIRECTIONAL; RADIATION DELIVERY; RADIATION FIELD; RESEARCH OPPORTUNITIES; RESEARCH PLATFORMS; ROBOTIC CONTROLS; SMALL ANIMAL;

EID: 77955807442     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2010.5509898     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 2
    • 63649090760 scopus 로고    scopus 로고
    • Development of an image-guided conformal small animal irradiation platform
    • June
    • P. Lindsay, S. Ansell, D. Moseley, S. Jelveh, R. Hill, and D. Jaffray, "Development of an image-guided conformal small animal irradiation platform," Journal of Medical Physics, vol. 35, no. 6, pp. 2695-2695, June 2008.
    • (2008) Journal of Medical Physics , vol.35 , Issue.6 , pp. 2695-2695
    • Lindsay, P.1    Ansell, S.2    Moseley, D.3    Jelveh, S.4    Hill, R.5    Jaffray, D.6
  • 3
    • 47849125647 scopus 로고    scopus 로고
    • A novel high resolution micro-radiotherapy system for small animal irradiation for cancer research
    • S. Wang, Z. Liu, S. Sultana, E. Schreiber, O. Zhou, and S. Chang, "A novel high resolution micro-radiotherapy system for small animal irradiation for cancer research," Journal of BioFactors, vol. 30, pp. 265-270, 2007.
    • (2007) Journal of BioFactors , vol.30 , pp. 265-270
    • Wang, S.1    Liu, Z.2    Sultana, S.3    Schreiber, E.4    Zhou, O.5    Chang, S.6
  • 5
    • 35648929294 scopus 로고    scopus 로고
    • Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner
    • Nov
    • E. Graves, H. Zhou, R. Chatterjee, P. Keall, S. Gambhir, C. Contag, and A. Boyer, "Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner," Journal of Medical Physics, vol. 34, no. 11, pp. 4359-4367, Nov 2007.
    • (2007) Journal of Medical Physics , vol.34 , Issue.11 , pp. 4359-4367
    • Graves, E.1    Zhou, H.2    Chatterjee, R.3    Keall, P.4    Gambhir, S.5    Contag, C.6    Boyer, A.7
  • 11
    • 38149118220 scopus 로고    scopus 로고
    • A fast algorithm for solving a linear feasibility problem with application to intensity-modulated radiation therapy
    • G. T. Herman and W. Chena, "A fast algorithm for solving a linear feasibility problem with application to intensity-modulated radiation therapy," Linear Algebra and its Applications, vol. 428, pp. 1207-1217, 2008.
    • (2008) Linear Algebra and Its Applications , vol.428 , pp. 1207-1217
    • Herman, G.T.1    Chena, W.2
  • 13
    • 38149033794 scopus 로고    scopus 로고
    • Linear and nonlinear models and algorithms in intensity-modulated radiation therapy
    • Y. Censor, J. M. Galvin, Y. Xiao, and M. Langer, "Linear and nonlinear models and algorithms in intensity-modulated radiation therapy," Linear Algebra and its Applications, vol. 428, pp. 1203-1206, 2008.
    • (2008) Linear Algebra and Its Applications , vol.428 , pp. 1203-1206
    • Censor, Y.1    Galvin, J.M.2    Xiao, Y.3    Langer, M.4
  • 15
    • 77955788224 scopus 로고    scopus 로고
    • Dose calculations - Collapsed cone convolution superposition and delta pixel beam
    • T. McNutt, "Dose calculations - collapsed cone convolution superposition and delta pixel beam," Philips Medical Systems, www.medical.philips.com/main/products/ros/products/pinnacle3/.
    • Philips Medical Systems
    • McNutt, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.