Design, validation, and implementation of a rapid-injection NMR system

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL PROCESS; CHEMICAL REAGENTS; DESIGN CRITERION; NMR SPECTROSCOPY; NMR TUBES; ORGANIC REACTION MECHANISMS; RAPID ACQUISITION; REAL TIME; REPRODUCIBILITIES; RESEARCH PROBLEMS;

EID: 77955680491     PISSN: 00223263     EISSN: 15206904     Source Type: Journal    
DOI: 10.1021/jo100837a     Document Type: Article
Times cited : (40)

References (63)
  • 2
    • 11844259698 scopus 로고    scopus 로고
    • Mahrwald R., Ed.; Wiley-VCH: Weinheim, Chapter 7
    • Denmark, S. E.; Fujimori, S. In Modern Aldol Reactions; Mahrwald, R., Ed.; Wiley-VCH: Weinheim, 2004, Vol. 2, Chapter 7.
    • (2004) Modern Aldol Reactions , vol.2
    • Denmark, S.E.1    Fujimori, S.2
  • 5
  • 37
    • 77955702460 scopus 로고    scopus 로고
    • The rates of travel are controllable, but increasing or decreasing them too far can cause the pistons to not seat properly, leaving them in an intermediary position and unable to move without resetting them manually
    • The rates of travel are controllable, but increasing or decreasing them too far can cause the pistons to not seat properly, leaving them in an intermediary position and unable to move without resetting them manually.
  • 38
    • 77955673727 scopus 로고    scopus 로고
    • Titanium tubing was made of A40 (<0.04% iron), 0.083′′ o.d., 0.063′′ i.d., 60′′ long
    • Titanium tubing was made of A40 (<0.04% iron), 0.083′′ o.d., 0.063′′ i.d., 60′′ long.
  • 39
    • 77955671378 scopus 로고    scopus 로고
    • Although more costly and more difficult to machine than stainless steel or brass, initial testing with stainless steel tubing resulted in poor line shape, even at room temperature
    • Although more costly and more difficult to machine than stainless steel or brass, initial testing with stainless steel tubing resulted in poor line shape, even at room temperature.
  • 40
    • 77955695625 scopus 로고    scopus 로고
    • In practice, small changes to this lateral alignment can be made manually as needed
    • In practice, small changes to this lateral alignment can be made manually as needed.
  • 41
    • 77955699581 scopus 로고    scopus 로고
    • Later designs also required a slight modification: A small amount of the inside of the sleeve was removed to compensate for the braise point where the tip was attached to the injector tube
    • Later designs also required a slight modification: A small amount of the inside of the sleeve was removed to compensate for the braise point where the tip was attached to the injector tube.
  • 42
    • 77955700895 scopus 로고    scopus 로고
    • The wires used for cleaning microliter syringes can also be useful in clearing clogged ports
    • The wires used for cleaning microliter syringes can also be useful in clearing clogged ports.
  • 43
    • 11844259698 scopus 로고    scopus 로고
    • Mahrwald R., Ed.; Wiley-VCH: Weinheim, Chapter 7
    • Denmark, S. E.; Fujimori, S. In Modern Aldol Reactions; Mahrwald, R., Ed.; Wiley-VCH: Weinheim, 2004; Vol. 2. Chapter 7.
    • (2004) Modern Aldol Reactions , vol.2
    • Denmark, S.E.1    Fujimori, S.2
  • 48
    • 77955700448 scopus 로고    scopus 로고
    • a, Δ H, and Δ G) differ from the accepted ReactIR numbers by less than 1 kcal/mol
    • a, Δ H, and Δ G) differ from the accepted ReactIR numbers by less than 1 kcal/mol.
  • 50
    • 77955688294 scopus 로고    scopus 로고
    • In other words, the order in HMPA is the ratio of the molecularity in the transition state divided by the molecularity in the ground state
    • In other words, the order in HMPA is the ratio of the molecularity in the transition state divided by the molecularity in the ground state.
  • 59
    • 77955670031 scopus 로고    scopus 로고
    • 1/2 = ca. 80 s (0.020 M in 7, -60 °C); epoxide opening of 12b, ca. 1800 s (0.025 M in 12b, -75 °C)
    • 1/2 = ca. 80 s (0.020 M in 7, -60 °C); epoxide opening of 12b, ca. 1800 s (0.025 M in 12b, -75 °C).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.