메뉴 건너뛰기




Volumn 21, Issue 2, 2010, Pages 123-129

Preload loss and bacterial penetration on different implant-abutment connection systems

Author keywords

Bacterial penetration; Dental implants; Microgap; Preload

Indexed keywords


EID: 77955646947     PISSN: 01036440     EISSN: 18064760     Source Type: Journal    
DOI: 10.1590/s0103-64402010000200006     Document Type: Article
Times cited : (72)

References (20)
  • 1
    • 60049100273 scopus 로고    scopus 로고
    • Prospective clinical evaluation of 1920 Morse taper connection implants: Results after 4 years of functional loading
    • Mangano C, Mangano F, Piattelli A, Iezzi G, Mangano A, La Colla L. Prospective clinical evaluation of 1920 Morse taper connection implants: results after 4 years of functional loading. Clin Oral Implants Res 2009;20:254-261.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 254-261
    • Mangano, C.1    Mangano, F.2    Piattelli, A.3    Iezzi, G.4    Mangano, A.5    la Colla, L.6
  • 2
    • 0024041059 scopus 로고
    • A multicenter report on osseointegrated oral implants
    • Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent 1988;60:75-84.
    • (1988) J Prosthet Dent , vol.60 , pp. 75-84
    • Albrektsson, T.1
  • 3
    • 0038505307 scopus 로고    scopus 로고
    • Cyclic loading of implant-supported prostheses: Changes in component fit over time
    • Hecker DM, Eckert SE. Cyclic loading of implant-supported prostheses: changes in component fit over time. J Prosthet Dent 2003;89:346-351.
    • (2003) J Prosthet Dent , vol.89 , pp. 346-351
    • Hecker, D.M.1    Eckert, S.E.2
  • 5
    • 85047681494 scopus 로고    scopus 로고
    • Micromotion and dynamic fatigue properties of the dental implant-abutment interface
    • Gratton DG, Aquilino SA, Stanford CM. Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent 2001;85:47-52.
    • (2001) J Prosthet Dent , vol.85 , pp. 47-52
    • Gratton, D.G.1    Aquilino, S.A.2    Stanford, C.M.3
  • 6
    • 0036199678 scopus 로고    scopus 로고
    • The causes of early implant bone loss: Myth or science?
    • Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002;73:322-333.
    • (2002) J Periodontol , vol.73 , pp. 322-333
    • Oh, T.J.1    Yoon, J.2    Misch, C.E.3    Wang, H.L.4
  • 9
    • 54249127386 scopus 로고    scopus 로고
    • Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs
    • Weng D, Nagata MJ, Bell M, Bosco AF, de Melo LG, Richter EJ. Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs. Clin Oral Implants Res 2008;19:1141-1147.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1141-1147
    • Weng, D.1    Nagata, M.J.2    Bell, M.3    Bosco, A.F.4    de Melo, L.G.5    Richter, E.J.6
  • 10
    • 34548693191 scopus 로고    scopus 로고
    • Spontaneous progression of ligature induced peri-implantitis at implants with different surface roughness: An experimental study in dogs
    • Berglundh T, Gotfredsen K, Zitzmann NU, Lang NP, Lindhe J. Spontaneous progression of ligature induced peri-implantitis at implants with different surface roughness: an experimental study in dogs. Clin Oral Implants Res 2007;18:655-661.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 655-661
    • Berglundh, T.1    Gotfredsen, K.2    Zitzmann, N.U.3    Lang, N.P.4    Lindhe, J.5
  • 11
    • 27544507238 scopus 로고    scopus 로고
    • In vitro evaluation of the implant-abutment bacterial seal: The locking taper system
    • Dibart S, Warbington M, Su MF, Skobe. Z. In vitro evaluation of the implant-abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants 2005;20:732-737.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 732-737
    • Dibart, S.1    Warbington, M.2    Su, M.F.3    Skobe, Z.4
  • 12
    • 0033074393 scopus 로고    scopus 로고
    • Assessment of cold welding properties of the internal conical interface of two commercially available implant systems
    • Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent 1999;81:159-166.
    • (1999) J Prosthet Dent , vol.81 , pp. 159-166
    • Norton, M.R.1
  • 13
    • 0032617145 scopus 로고    scopus 로고
    • Microleakage at the abutmentimplant interface of osseointegrated implants: A comparative study
    • Gross M, Abramovich I, Weiss EI. Microleakage at the abutmentimplant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants 1999;14:94-100.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 94-100
    • Gross, M.1    Abramovich, I.2    Weiss, E.I.3
  • 14
    • 0032085212 scopus 로고    scopus 로고
    • Bacterial leakage into and from prefabricated screw-retained implant-borne crowns in vitro
    • Guindy JS, Besimo CE, Besimo R, Schiel H, Meyer J. Bacterial leakage into and from prefabricated screw-retained implant-borne crowns in vitro. J Oral Rehabil 1998;25:403-408.
    • (1998) J Oral Rehabil , vol.25 , pp. 403-408
    • Guindy, J.S.1    Besimo, C.E.2    Besimo, R.3    Schiel, H.4    Meyer, J.5
  • 15
  • 17
    • 0028701189 scopus 로고
    • Microbial penetration along the implant components of the Branemark system. An in vitro Study
    • Quirynen M, Bollen CM, Eyssen H, van Steenberghe D. Microbial penetration along the implant components of the Branemark system. An in vitro study. Clin Oral Implants Res 1994;5:239-244.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 239-244
    • Quirynen, M.1    Bollen, C.M.2    Eyssen, H.3    van Steenberghe, D.4
  • 18
    • 0036365977 scopus 로고    scopus 로고
    • Removal torques of conical, tapered implant abutments: The effects of anodization and reduction of surface area
    • Squier RS, Psoter WJ, Taylor TD. Removal torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area. Int J Oral Maxillofac Implants 2002;17:24-27.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 24-27
    • Squier, R.S.1    Psoter, W.J.2    Taylor, T.D.3
  • 19
    • 0035459995 scopus 로고    scopus 로고
    • Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implantabutment connections
    • Piattelli A, Scarano A, Paolantonio M, Assenza B, Leghissa GC, Di Bonaventura G, et al. Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implantabutment connections. J Periodontol 2001;72:1146-1150.
    • (2001) J Periodontol , vol.72 , pp. 1146-1150
    • Piattelli, A.1    Scarano, A.2    Paolantonio, M.3    Assenza, B.4    Leghissa, G.C.5    di Bonaventura, G.6
  • 20
    • 30844432439 scopus 로고    scopus 로고
    • In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
    • Steinebrunner L, Wolfart S, Bossmann K, Kern M. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. Int J Oral Maxillofac Implants 2005;20:875-881.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 875-881
    • Steinebrunner, L.1    Wolfart, S.2    Bossmann, K.3    Kern, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.