메뉴 건너뛰기




Volumn 2, Issue 4, 2010, Pages 383-393

Gadofosveset injection for magnetic resonance angiography

Author keywords

cardiovascular system; gadofosveset trisodium; MRA; MS325

Indexed keywords

ABLAVAR; GADOBUTROL; GADOFOSVESET; GADOMER 17; SUPERPARAMAGNETIC IRON OXIDE; ULTRASMALL SUPERPARAMAGNETIC IRON OXIDE; UNCLASSIFIED DRUG;

EID: 77955581021     PISSN: 17555191     EISSN: 17555205     Source Type: Journal    
DOI: 10.2217/iim.10.39     Document Type: Review
Times cited : (4)

References (62)
  • 1
    • 36348948529 scopus 로고    scopus 로고
    • MR angiography with blood pool contrast agents
    • Bremerich J, Bilecen D, Reimer P: MR angiography with blood pool contrast agents. Eur. Radiol. 17, 3017-3024 (2007).
    • (2007) Eur. Radiol. , vol.17 , pp. 3017-3024
    • Bremerich, J.1    Bilecen, D.2    Reimer, P.3
  • 2
    • 0029127024 scopus 로고
    • Dynamic contrast-enhanced subtraction MR angiography of the lower extremities: Initial evaluation with a multisection two-dimensional time-of-flight sequence
    • Adamis MK, Li W, Wielopolski PA et al.: Dynamic contrast-enhanced subtraction MR angiography of the lower extremities: initial evaluation with a multisection two-dimensional time-of-flight sequence. Radiology 196, 689-695 (1995).
    • (1995) Radiology , vol.196 , pp. 689-695
    • Adamis, M.K.1    Li, W.2    Wielopolski, P.A.3
  • 3
    • 0031862273 scopus 로고    scopus 로고
    • Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
    • Grist TM, Korosec FR, Peters DC et al.: Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 207, 539-544 (1998).
    • (1998) Radiology , vol.207 , pp. 539-544
    • Grist, T.M.1    Korosec, F.R.2    Peters, D.C.3
  • 4
    • 0029758290 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced 3D MR angiography. Magnetic resonance in medicine
    • Korosec FR, Frayne R, Grist TM, Mistretta CA: Time-resolved contrast-enhanced 3D MR angiography. Magnetic resonance in medicine. Magn. Reson. Med. Sci. 36, 345-351 (1996).
    • (1996) Magn. Reson. Med. Sci. , vol.36 , pp. 345-351
    • Korosec, F.R.1    Frayne, R.2    Grist, T.M.3    Mistretta, C.A.4
  • 5
    • 0031021058 scopus 로고    scopus 로고
    • Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging
    • Krinsky GA, Rofsky NM, DeCorato DR et al.: Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging. Radiology 202, 183-193 (1997).
    • (1997) Radiology , vol.202 , pp. 183-193
    • Krinsky, G.A.1    Rofsky, N.M.2    Decorato, D.R.3
  • 6
    • 0029948193 scopus 로고    scopus 로고
    • Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries
    • Levy RA, Prince MR: Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries. AJR Am. J. Roentgenol. 167, 211-215 (1996).
    • (1996) AJR Am. J. Roentgenol. , vol.167 , pp. 211-215
    • Levy, R.A.1    Prince, M.R.2
  • 7
    • 0029891116 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta
    • Prince MR, Narasimham DL, Jacoby WT et al.: Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta. AJR Am. J. Roentgenol. 166, 1387-1397 (1996).
    • (1996) AJR Am. J. Roentgenol. , vol.166 , pp. 1387-1397
    • Prince, M.R.1    Narasimham, D.L.2    Jacoby, W.T.3
  • 9
    • 0029022698 scopus 로고
    • Magnetic resonance angiography in the preoperative evaluation of abdominal aortic aneurysms
    • discussion 899
    • Petersen MJ, Cambria RP, Kaufman JA et al.: Magnetic resonance angiography in the preoperative evaluation of abdominal aortic aneurysms. J. Vasc. Surg. 21, 891-898; discussion 899 (1995).
    • (1995) J. Vasc. Surg. , vol.21 , pp. 891-898
    • Petersen, M.J.1    Cambria, R.P.2    Kaufman, J.A.3
  • 10
    • 0028884196 scopus 로고
    • Contrast-enhanced three-dimensional MR angiography in a single breath-hold: A novel technique
    • Shetty AN, Shirkhoda A, Bis KG, Alcantara A: Contrast-enhanced three-dimensional MR angiography in a single breath-hold: a novel technique. AJR Am. J. Roentgenol. 165, 1290-1292 (1995).
    • (1995) AJR Am. J. Roentgenol. , vol.165 , pp. 1290-1292
    • Shetty, A.N.1    Shirkhoda, A.2    Bis, K.G.3    Alcantara, A.4
  • 11
    • 0030040997 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced MR angiography for aortoiliac inflow assessment plus renal artery screening in a single breath hold
    • Snidow JJ, Johnson MS, Harris VJ et al.: Three-dimensional gadolinium-enhanced MR angiography for aortoiliac inflow assessment plus renal artery screening in a single breath hold. Radiology 198, 725-732 (1996).
    • (1996) Radiology , vol.198 , pp. 725-732
    • Snidow, J.J.1    Johnson, M.S.2    Harris, V.J.3
  • 12
    • 60749086794 scopus 로고    scopus 로고
    • Ultrasmall superparamagnetic iron oxides (USPIOs): A future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?
    • Neuwelt EA, Hamilton BE, Varallyay CG et al.: Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)? Kidney Int. 75, 465-474 (2009).
    • (2009) Kidney Int. , vol.75 , pp. 465-474
    • Neuwelt, E.A.1    Hamilton, B.E.2    Varallyay, C.G.3
  • 14
    • 0031435887 scopus 로고    scopus 로고
    • Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging
    • Parmelee DJ, Walovitch RC, Ouellet HS, Lauffer RB: Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging. Invest. Radiol. 32, 741-747 (1997).
    • (1997) Invest. Radiol. , vol.32 , pp. 741-747
    • Parmelee, D.J.1    Walovitch, R.C.2    Ouellet, H.S.3    Lauffer, R.B.4
  • 15
    • 67651098771 scopus 로고    scopus 로고
    • Protein-targeted gadolinium-based magnetic resonance imaging (MRI) contrast agents: Design and mechanism of action
    • Caravan P: Protein-targeted gadolinium-based magnetic resonance imaging (MRI) contrast agents: design and mechanism of action. Acc. Chem. Res. 42, 851-862 (2009).
    • (2009) Acc. Chem. Res. , vol.42 , pp. 851-862
    • Caravan, P.1
  • 16
    • 0037181390 scopus 로고    scopus 로고
    • The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates
    • Caravan P, Cloutier NJ, Greenfield MT et al.: The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates. J. Am. Chem. Soc. 124, 3152-3162 (2002).
    • (2002) J. Am. Chem. Soc. , vol.124 , pp. 3152-3162
    • Caravan, P.1    Cloutier, N.J.2    Greenfield, M.T.3
  • 17
    • 0035937915 scopus 로고    scopus 로고
    • Thermodynamic stability and kinetic inertness of MS-325, a new blood pool agent for magnetic resonance imaging
    • Caravan P, Comuzzi C, Crooks W, McMurry TJ, Choppin GR, Woulfe SR: Thermodynamic stability and kinetic inertness of MS-325, a new blood pool agent for magnetic resonance imaging. Inorg. Chem. 40, 2170-2176 (2001).
    • (2001) Inorg. Chem. , vol.40 , pp. 2170-2176
    • Caravan, P.1    Comuzzi, C.2    Crooks, W.3    McMurry, T.J.4    Choppin, G.R.5    Woulfe, S.R.6
  • 18
    • 0031836465 scopus 로고    scopus 로고
    • MS-325: Albumin-targeted contrast agent for MR angiography
    • Lauffer RB, Parmelee DJ, Dunham SU et al.: MS-325: albumin-targeted contrast agent for MR angiography. Radiology 207, 529-538 (1998).
    • (1998) Radiology , vol.207 , pp. 529-538
    • Lauffer, R.B.1    Parmelee, D.J.2    Dunham, S.U.3
  • 19
    • 0032755672 scopus 로고    scopus 로고
    • Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography
    • Stuber M, Botnar RM, Danias PG et al.: Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J. Magn. Reson. Imaging 10, 790-799 (1999).
    • (1999) J. Magn. Reson. Imaging , vol.10 , pp. 790-799
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 20
    • 38949213662 scopus 로고    scopus 로고
    • Magnetic resonance coronary angiography with Vasovist: In vivo T1 estimation to improve image quality of navigator and breath-hold techniques
    • Nassenstein K, Waltering K-U, Kelle S et al.: Magnetic resonance coronary angiography with Vasovist: in vivo T1 estimation to improve image quality of navigator and breath-hold techniques. Eur. Radiol. 18, 103-109 (2008).
    • (2008) Eur. Radiol. , vol.18 , pp. 103-109
    • Nassenstein, K.1    Waltering, K.-U.2    Kelle, S.3
  • 21
    • 0038101683 scopus 로고    scopus 로고
    • Development of new glucosylated derivatives of gadolinium diethylenetriaminepentaacetic for magnetic resonance angiography
    • Burtea C, Laurent S, Colet J-M, Vander Elst L, Muller RN: Development of new glucosylated derivatives of gadolinium diethylenetriaminepentaacetic for magnetic resonance angiography. Invest. Radiol. 38, 320-333 (2003).
    • (2003) Invest. Radiol. , vol.38 , pp. 320-333
    • Burtea, C.1    Laurent, S.2    Colet, J.-M.3    Vander Elst, L.4    Muller, R.N.5
  • 22
    • 0037345827 scopus 로고    scopus 로고
    • Macromolecular MRI contrast agents with small dendrimers: Pharmacokinetic differences between sizes and cores
    • Kobayashi H, Kawamoto S, Jo S-K, Bryant HL, Brechbiel MW, Star RA: Macromolecular MRI contrast agents with small dendrimers: pharmacokinetic differences between sizes and cores. Bioconjug. Chem. 14, 388-394 (2003).
    • (2003) Bioconjug. Chem. , vol.14 , pp. 388-394
    • Kobayashi, H.1    Kawamoto, S.2    Jo, S.-K.3    Bryant, H.L.4    Brechbiel, M.W.5    Star, R.A.6
  • 23
    • 0026264051 scopus 로고
    • AUR Memorial Award 1991. Immunogenicity of gadolinium-based contrast agents for magnetic resonance imaging. Induction and characterization of antibodies in animals
    • Baxter AB, Melnikoff S, Stites DP, Brasch RC: AUR Memorial Award 1991. Immunogenicity of gadolinium-based contrast agents for magnetic resonance imaging. Induction and characterization of antibodies in animals. Invest. Radiol. 26, 1035-1040 (1991).
    • (1991) Invest. Radiol. , vol.26 , pp. 1035-1040
    • Baxter, A.B.1    Melnikoff, S.2    Stites, D.P.3    Brasch, R.C.4
  • 24
    • 33646379879 scopus 로고    scopus 로고
    • Effect of field strengths on magnetic resonance angiography: Comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 Tesla
    • Allkemper T, Heindel W, Kooijman H, Ebert W, Tombach B: Effect of field strengths on magnetic resonance angiography: comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 Tesla. Invest. Radiol. 41, 97-104 (2006).
    • (2006) Invest. Radiol. , vol.41 , pp. 97-104
    • Allkemper, T.1    Heindel, W.2    Kooijman, H.3    Ebert, W.4    Tombach, B.5
  • 26
    • 0035413308 scopus 로고    scopus 로고
    • Artery-vein separation via MRA - An image processing approach
    • Lei T, Udupa JK, Saha PK, Odhner D: Artery-vein separation via MRA - an image processing approach. IEEE Trans. Med. Imaging 20, 689-703 (2001).
    • (2001) IEEE Trans. Med. Imaging , vol.20 , pp. 689-703
    • Lei, T.1    Udupa, J.K.2    Saha, P.K.3    Odhner, D.4
  • 27
    • 0036232421 scopus 로고    scopus 로고
    • 3D MRA visualization and artery-vein separation using blood-pool contrast agent MS-325
    • Lei T, Udupa JK, Saha PK et al.: 3D MRA visualization and artery-vein separation using blood-pool contrast agent MS-325. Acad. Radiol. 9(Suppl. 1), S127-S133 (2002).
    • (2002) Acad. Radiol. , vol.9 , Issue.SUPPL. 1
    • Lei, T.1    Udupa, J.K.2    Saha, P.K.3
  • 28
    • 51449114651 scopus 로고    scopus 로고
    • Double-reference cross-correlation algorithm for separation of the arteries and veins from 3D MRA time series
    • Santini F, Patil S, Meckel S, Scheffler K, Wetzel SG: Double-reference cross-correlation algorithm for separation of the arteries and veins from 3D MRA time series. J. Magn. Reson. Imaging 28, 646-654 (2008).
    • (2008) J. Magn. Reson. Imaging , vol.28 , pp. 646-654
    • Santini, F.1    Patil, S.2    Meckel, S.3    Scheffler, K.4    Wetzel, S.G.5
  • 30
    • 0030210712 scopus 로고    scopus 로고
    • MS-325: A small-molecule vascular imaging agent for magnetic resonance imaging
    • Lauffer RB, Parmelee DJ, Ouellet HS et al.: MS-325: a small-molecule vascular imaging agent for magnetic resonance imaging. Acad. Radiol. 3(Suppl. 2), S356-S358 (1996).
    • (1996) Acad. Radiol. , vol.3 , Issue.SUPPL. 2
    • Lauffer, R.B.1    Parmelee, D.J.2    Ouellet, H.S.3
  • 31
    • 0028007063 scopus 로고
    • Dynamic contrast-enhanced MR imaging of the upper abdomen: Enhancement properties of gadobutrol, gadolinium-DTPA-polylysine, and gadolinium-DTPA- cascade-polymer
    • Adam G, Neuerburg J, Spntrup E, Mhler A, Scherer K, Gnther RW: Dynamic contrast-enhanced MR imaging of the upper abdomen: enhancement properties of gadobutrol, gadolinium-DTPA-polylysine, and gadolinium-DTPA-cascade-polymer. Magn. Reson. Med. 32, 622-628 (1994).
    • (1994) Magn. Reson. Med. , vol.32 , pp. 622-628
    • Adam, G.1    Neuerburg, J.2    Spntrup, E.3    Mhler, A.4    Scherer, K.5    Gnther, R.W.6
  • 32
    • 0027173863 scopus 로고
    • A new macromolecule as a contrast agent for MR angiography: Preparation, properties, and animal studies
    • Bogdanov AA, Weissleder R, Frank HW et al.: A new macromolecule as a contrast agent for MR angiography: preparation, properties, and animal studies. Radiology 187, 701-706 (1993).
    • (1993) Radiology , vol.187 , pp. 701-706
    • Bogdanov, A.A.1    Weissleder, R.2    Frank, H.W.3
  • 33
    • 0028302015 scopus 로고
    • Quantitation of saturation effects versus dose in three-dimensional time-of-flight magnetic resonance angiography with blood-pool contrast agents
    • Desser TS, Rubin DL, Fan Q et al.: Quantitation of saturation effects versus dose in three-dimensional time-of-flight magnetic resonance angiography with blood-pool contrast agents. Invest. Radiol. 29(Suppl. 2), S65-S68 (1994).
    • (1994) Invest. Radiol. , vol.29 , Issue.SUPPL. 2
    • Desser, T.S.1    Rubin, D.L.2    Fan, Q.3
  • 34
    • 0025719624 scopus 로고
    • Paramagnetic dextrans as magnetic resonance contrast agents
    • S50-S52; discussion
    • Meyer D, Schaefer M, Bouillot A, Beaut S, Chambon C: Paramagnetic dextrans as magnetic resonance contrast agents. Invest. Radiol. 26(Suppl. 1), S50-S52; discussion S60-S64 (1991).
    • (1991) Invest. Radiol. , vol.26 , Issue.SUPPL. 1
    • Meyer, D.1    Schaefer, M.2    Bouillot, A.3    Beaut, S.4    Chambon, C.5
  • 35
    • 0022975664 scopus 로고
    • Comparison of the contrast-enhancing properties of albumin-(Gd-DTPA) and Gd-DTPA at 2.0 T: And experimental study in rats
    • Schmiedl U, Ogan MD, Moseley ME, Brasch RC: Comparison of the contrast-enhancing properties of albumin-(Gd-DTPA) and Gd-DTPA at 2.0 T: and experimental study in rats. AJR Am. J. Roentgenol. 147, 1263-1270 (1986).
    • (1986) AJR Am. J. Roentgenol. , vol.147 , pp. 1263-1270
    • Schmiedl, U.1    Ogan, M.D.2    Moseley, M.E.3    Brasch, R.C.4
  • 36
    • 0025259293 scopus 로고
    • Evaluation of Gd-DTPA-labeled dextran as an intravascular MR contrast agent: Imaging characteristics in normal rat tissues
    • Wang SC, Wikstrm MG, White DL et al.: Evaluation of Gd-DTPA-labeled dextran as an intravascular MR contrast agent: imaging characteristics in normal rat tissues. Radiology 175, 483-488 (1990).
    • (1990) Radiology , vol.175 , pp. 483-488
    • Wang, S.C.1    Wikstrm, M.G.2    White, D.L.3
  • 37
    • 0344584515 scopus 로고    scopus 로고
    • MR angiography with gadofosveset trisodium for peripheral vascular disease: Phase II trial
    • Perreault P, Edelman MA, Baum RA et al.: MR angiography with gadofosveset trisodium for peripheral vascular disease: Phase II trial. Radiology. 229(3), 811-820. (2003).
    • (2003) Radiology , vol.229 , Issue.3 , pp. 811-820
    • Perreault, P.1    Edelman, M.A.2    Baum, R.A.3
  • 38
    • 23844477876 scopus 로고    scopus 로고
    • MR angiography of aortoiliac occlusive disease: A Phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325
    • Goyen M, Edelman M, Perreault P et al.: MR angiography of aortoiliac occlusive disease: a Phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325. Radiology 236, 825-833 (2005).
    • (2005) Radiology , vol.236 , pp. 825-833
    • Goyen, M.1    Edelman, M.2    Perreault, P.3
  • 39
    • 20744455805 scopus 로고    scopus 로고
    • Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: Safety and efficacy of gadofosveset-enhanced MR angiography - Multicenter comparative Phase III study
    • Rapp JH, Wolff SD, Quinn SF et al.: Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: safety and efficacy of gadofosveset-enhanced MR angiography - multicenter comparative Phase III study. Radiology 236, 71-78 (2005).
    • (2005) Radiology , vol.236 , pp. 71-78
    • Rapp, J.H.1    Wolff, S.D.2    Quinn, S.F.3
  • 40
    • 56149116587 scopus 로고    scopus 로고
    • Peripheral MR angiography with blood pool contrast agent: Prospective intraindividual comparative study of high-spatial-resolution steady-state MR angiography versus standard-resolution first-pass MR angiography and DSA
    • Hadizadeh DR, Gieseke J, Lohmaier SH et al.: Peripheral MR angiography with blood pool contrast agent: prospective intraindividual comparative study of high-spatial-resolution steady-state MR angiography versus standard-resolution first-pass MR angiography and DSA. Radiology 249, 701-711 (2008).
    • (2008) Radiology , vol.249 , pp. 701-711
    • Hadizadeh, D.R.1    Gieseke, J.2    Lohmaier, S.H.3
  • 41
    • 73949159224 scopus 로고    scopus 로고
    • MR angiography of infrapopliteal arteries in patients with peripheral arterial occlusive disease by using gadofosveset at 3.0 T: Diagnostic accuracy compared with selective DSA
    • Bonel HM, Saar B, Hoppe H et al.: MR angiography of infrapopliteal arteries in patients with peripheral arterial occlusive disease by using gadofosveset at 3.0 T: diagnostic accuracy compared with selective DSA. Radiology 253, 879-890 (2009).
    • (2009) Radiology , vol.253 , pp. 879-890
    • Bonel, H.M.1    Saar, B.2    Hoppe, H.3
  • 42
    • 34547879246 scopus 로고    scopus 로고
    • First-pass whole-body magnetic resonance angiography (MRA) using the blood-pool contrast medium gadofosveset trisodium: Comparison to gadopentetate dimeglumine
    • Klessen C, Hein PA, Huppertz A et al.: First-pass whole-body magnetic resonance angiography (MRA) using the blood-pool contrast medium gadofosveset trisodium: comparison to gadopentetate dimeglumine. Invest. Radiol. 42, 659-664 (2007).
    • (2007) Invest. Radiol. , vol.42 , pp. 659-664
    • Klessen, C.1    Hein, P.A.2    Huppertz, A.3
  • 43
    • 77749243437 scopus 로고    scopus 로고
    • Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease
    • Grijalba FU, Esandi MC: Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease. Acta Radiol. 51(3), 284-289 (2010).
    • (2010) Acta Radiol. , vol.51 , Issue.3 , pp. 284-289
    • Grijalba, F.U.1    Esandi, M.C.2
  • 44
    • 65549137407 scopus 로고    scopus 로고
    • Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium
    • Nielsen YW, Eiberg JP, Lgager VB, Hansen MA, Schroeder TV, Thomsen HS: Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium. Acad. Radiol. 16, 654-661 (2009).
    • (2009) Acad. Radiol. , vol.16 , pp. 654-661
    • Nielsen, Y.W.1    Eiberg, J.P.2    Lgager, V.B.3    Hansen, M.A.4    Schroeder, T.V.5    Thomsen, H.S.6
  • 45
    • 67651065568 scopus 로고    scopus 로고
    • Contrast-enhanced whole-heart MR coronary angiography at 3.0 T using the intravascular contrast agent gadofosveset
    • Prompona M, Cyran C, Nikolaou K, Bauner K, Reiser M, Huber A: Contrast-enhanced whole-heart MR coronary angiography at 3.0 T using the intravascular contrast agent gadofosveset. Invest. Radiol. 44, 369-374 (2009).
    • (2009) Invest. Radiol. , vol.44 , pp. 369-374
    • Prompona, M.1    Cyran, C.2    Nikolaou, K.3    Bauner, K.4    Reiser, M.5    Huber, A.6
  • 46
    • 36148982243 scopus 로고    scopus 로고
    • Whole-heart coronary magnetic resonance angiography with MS-325 (Gadofosveset)
    • Kelle S, Thouet T, Tangcharoen T et al.: Whole-heart coronary magnetic resonance angiography with MS-325 (Gadofosveset). Med. Sci. Monit. 13, CR469-CR474 (2007).
    • (2007) Med. Sci. Monit. , vol.13
    • Kelle, S.1    Thouet, T.2    Tangcharoen, T.3
  • 47
    • 38849183446 scopus 로고    scopus 로고
    • Visualization of the cardiac venous system using cardiac magnetic resonance
    • Chiribiri A, Kelle S, Gtze S et al.: Visualization of the cardiac venous system using cardiac magnetic resonance. Am. J. Cardiol. 101, 407-412 (2008).
    • (2008) Am. J. Cardiol. , vol.101 , pp. 407-412
    • Chiribiri, A.1    Kelle, S.2    Gtze, S.3
  • 48
    • 56049123379 scopus 로고    scopus 로고
    • Magnetic resonance cardiac vein imaging: Relation to mitral valve annulus and left circumflex coronary artery
    • Chiribiri A, Kelle S, Khler U et al.: Magnetic resonance cardiac vein imaging: relation to mitral valve annulus and left circumflex coronary artery. JACC Cardiovasc. Imaging 1, 729-738 (2008).
    • (2008) JACC Cardiovasc. Imaging , vol.1 , pp. 729-738
    • Chiribiri, A.1    Kelle, S.2    Khler, U.3
  • 49
    • 77955569825 scopus 로고    scopus 로고
    • Gadofosveset trisodium-enhanced magnetic resonance angiography of the left atrium-A feasibility study
    • Wagner M, Rief M, Asbach P et al.: Gadofosveset trisodium-enhanced magnetic resonance angiography of the left atrium-A feasibility study. Eur. J. Radiol. 51(3), 284-289 (2009).
    • (2009) Eur. J. Radiol. , vol.51 , Issue.3 , pp. 284-289
    • Wagner, M.1    Rief, M.2    Asbach, P.3
  • 50
    • 0035088061 scopus 로고    scopus 로고
    • Carotid MR angiography: Phase II study of safety and efficacy for MS-325
    • Bluemke DA, Stillman AE, Bis KG et al.: Carotid MR angiography: Phase II study of safety and efficacy for MS-325. Radiology 219, 114-122 (2001).
    • (2001) Radiology , vol.219 , pp. 114-122
    • Bluemke, D.A.1    Stillman, A.E.2    Bis, K.G.3
  • 51
    • 66149146677 scopus 로고    scopus 로고
    • Gadofosveset-enhanced MR angiography of carotid arteries: Does steady-state imaging improve accuracy of first-pass imaging? Comparison with selective digital subtraction angiography
    • Anzidei M, Napoli A, Marincola BC et al.: Gadofosveset-enhanced MR angiography of carotid arteries: does steady-state imaging improve accuracy of first-pass imaging? Comparison with selective digital subtraction angiography. Radiology 251, 457-466 (2009).
    • (2009) Radiology , vol.251 , pp. 457-466
    • Anzidei, M.1    Napoli, A.2    Marincola, B.C.3
  • 52
    • 77955006822 scopus 로고    scopus 로고
    • Preliminary experience with MRA in evaluating the degree of carotid stenosis and plaque morphology using high-resolution sequences after gadofosveset trisodium (Vasovist) administration: Comparison with CTA and DSA
    • Anzidei M, Napoli A, Geiger D et al.: Preliminary experience with MRA in evaluating the degree of carotid stenosis and plaque morphology using high-resolution sequences after gadofosveset trisodium (Vasovist) administration: comparison with CTA and DSA. Radiol. Med. 115(4), 634-647 (2010).
    • (2010) Radiol. Med. , vol.115 , Issue.4 , pp. 634-647
    • Anzidei, M.1    Napoli, A.2    Geiger, D.3
  • 53
    • 38749146504 scopus 로고    scopus 로고
    • A multi-center, comparative, Phase 3 study to determine the efficacy of gadofosveset-enhanced magnetic resonance angiography for evaluation of renal artery disease
    • McGregor R, Vymazal J, Martinez-Lopez M et al.: A multi-center, comparative, Phase 3 study to determine the efficacy of gadofosveset-enhanced magnetic resonance angiography for evaluation of renal artery disease. Eur. J. Radiol. 65, 316-325 (2008).
    • (2008) Eur. J. Radiol. , vol.65 , pp. 316-325
    • McGregor, R.1    Vymazal, J.2    Martinez-Lopez, M.3
  • 54
    • 37549008767 scopus 로고    scopus 로고
    • Safety and efficacy of gadofosveset-enhanced MR angiography for evaluation of pedal arterial disease: Multicenter comparative Phase 3 study
    • Bosch E, Kreitner K-F, Peirano MF et al.: Safety and efficacy of gadofosveset-enhanced MR angiography for evaluation of pedal arterial disease: multicenter comparative Phase 3 study. AJR Am. J. Roentgenol. 190, 179-186 (2008).
    • (2008) AJR Am. J. Roentgenol. , vol.190 , pp. 179-186
    • Bosch, E.1    Kreitner, K.-F.2    Peirano, M.F.3
  • 55
    • 70349671451 scopus 로고    scopus 로고
    • First-pass and steady-state magnetic resonance angiography of the thoracic vasculature using gadofosveset trisodium
    • Naehle CP, Mller A, Willinek WA et al.: First-pass and steady-state magnetic resonance angiography of the thoracic vasculature using gadofosveset trisodium. J. Magn. Reson. Imaging 30, 809-816 (2009).
    • (2009) J. Magn. Reson. Imaging , vol.30 , pp. 809-816
    • Naehle, C.P.1    Mller, A.2    Willinek, W.A.3
  • 56
    • 59249090546 scopus 로고    scopus 로고
    • Dynamic magnetic resonance angiography of the arteries of the hand. A comparison between an extracellular and an intravascular contrast agent
    • Reisinger C, Gluecker T, Jacob AL, Bongartz G, Bilecen D: Dynamic magnetic resonance angiography of the arteries of the hand. A comparison between an extracellular and an intravascular contrast agent. Eur. Radiol. 19, 495-502 (2009).
    • (2009) Eur. Radiol. , vol.19 , pp. 495-502
    • Reisinger, C.1    Gluecker, T.2    Jacob, A.L.3    Bongartz, G.4    Bilecen, D.5
  • 57
    • 74849090151 scopus 로고    scopus 로고
    • Preoperative planning of DIEP and SGAP flaps: Preliminary experience with magnetic resonance angiography using 3-tesla equipment and blood-pool contrast medium
    • Alonso-Burgos A, Garca-Tutor E, Bastarrika G, Benito A, Domnguez PD, Zubieta JL: Preoperative planning of DIEP and SGAP flaps: preliminary experience with magnetic resonance angiography using 3-tesla equipment and blood-pool contrast medium. J. Plast. Reconstr. Aesthet. Surg. 63, 298-304 (2010).
    • (2010) J. Plast. Reconstr. Aesthet. Surg. , vol.63 , pp. 298-304
    • Alonso-Burgos, A.1    Garca-Tutor, E.2    Bastarrika, G.3    Benito, A.4    Domnguez, P.D.5    Zubieta, J.L.6
  • 58
    • 0033498688 scopus 로고    scopus 로고
    • Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion. Cardiac MRI Group
    • Jerosch-Herold M, Wilke N, Wang Y et al.: Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion. Cardiac MRI Group. Int. J. Card. Imaging 15(6), 453-464 (1999).
    • (1999) Int. J. Card. Imaging , vol.15 , Issue.6 , pp. 453-464
    • Jerosch-Herold, M.1    Wilke, N.2    Wang, Y.3
  • 59
    • 0029056631 scopus 로고
    • Experimental gastrointestinal hemorrhage: Detection with contrast-enhanced MR imaging and scintigraphy
    • Gupta H, Weissleder R, Bogdanov AA, Brady TJ: Experimental gastrointestinal hemorrhage: detection with contrast-enhanced MR imaging and scintigraphy. Radiology 196, 239-244 (1995).
    • (1995) Radiology , vol.196 , pp. 239-244
    • Gupta, H.1    Weissleder, R.2    Bogdanov, A.A.3    Brady, T.J.4
  • 61
    • 13344269679 scopus 로고    scopus 로고
    • Mammary carcinoma model: Correlation of macromolecular contrast-enhanced MR imaging characterizations of tumor microvasculature and histologic capillary density
    • van Dijke CF, Brasch RC, Roberts TP et al.: Mammary carcinoma model: correlation of macromolecular contrast-enhanced MR imaging characterizations of tumor microvasculature and histologic capillary density. Radiology 198, 813-818 (1996).
    • (1996) Radiology , vol.198 , pp. 813-818
    • Van Dijke, C.F.1    Brasch, R.C.2    Roberts, T.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.