메뉴 건너뛰기




Volumn 54, Issue 3, 2010, Pages 133-142

Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysis

Author keywords

Cortical bone thickness; Dental implant; Finite element analysis; Posterior maxilla; Stress distribution

Indexed keywords

TOOTH IMPLANT;

EID: 77955568488     PISSN: 18831958     EISSN: 22124632     Source Type: Journal    
DOI: 10.1016/j.jpor.2009.12.004     Document Type: Article
Times cited : (90)

References (51)
  • 1
    • 0034268232 scopus 로고    scopus 로고
    • Branemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years
    • Bahat O. Branemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants 2000, 15:646-653.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 646-653
    • Bahat, O.1
  • 2
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Branemark implant in partially edentulous jaws: a 10-year prospective multicenter study
    • Lekholm U., Gunne J., Henry P., Higuchi K., Linden U., Bergstrom C., et al. Survival of the Branemark implant in partially edentulous jaws: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants 1999, 14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3    Higuchi, K.4    Linden, U.5    Bergstrom, C.6
  • 3
    • 0029438579 scopus 로고
    • Ten-year survival rates of fixed prostheses on four or six implants ad modum Branemark in full edentulism
    • Branemark P.I., Svensson B., van Steenberghe D. Ten-year survival rates of fixed prostheses on four or six implants ad modum Branemark in full edentulism. Clin Oral Implants Res 1995, 6:227-231.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 227-231
    • Branemark, P.I.1    Svensson, B.2    van Steenberghe, D.3
  • 5
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D., Mericske-Stern R., Bernard J.P., Behneke A., Behneke N., Hirt H.P., et al. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997, 8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3    Behneke, A.4    Behneke, N.5    Hirt, H.P.6
  • 6
    • 33947316124 scopus 로고    scopus 로고
    • Bone density assessments of oral implant sites using computerized tomography
    • Turkyilmaz I., Tozum T.F., Tumer C. Bone density assessments of oral implant sites using computerized tomography. J Oral Rehabil 2007, 34:267-272.
    • (2007) J Oral Rehabil , vol.34 , pp. 267-272
    • Turkyilmaz, I.1    Tozum, T.F.2    Tumer, C.3
  • 7
    • 0345507999 scopus 로고    scopus 로고
    • Bone density: a key determinant for clinical success
    • Mosby, St. Louis, C.E. Misch (Ed.)
    • Misch C.E. Bone density: a key determinant for clinical success. Contemporary implant dentistry 1999, 109-118. Mosby, St. Louis. 2nd ed. C.E. Misch (Ed.).
    • (1999) Contemporary implant dentistry , pp. 109-118
    • Misch, C.E.1
  • 8
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • Quintessence, Chicago, P.-I. Brånemark, G.A. Zarb, T. Albrektsson (Eds.)
    • Lekholm U., Zarb G.A. Patient selection and preparation. Tissue-integrated prostheses 1985, 199-209. Quintessence, Chicago. P.-I. Brånemark, G.A. Zarb, T. Albrektsson (Eds.).
    • (1985) Tissue-integrated prostheses , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 11
    • 0034208791 scopus 로고    scopus 로고
    • Implant placement in the maxillary tuberosity: the Summers' technique performed with modified osteotomes
    • Nocini P.F., Albanese M., Fior A., De Santis D. Implant placement in the maxillary tuberosity: the Summers' technique performed with modified osteotomes. Clin Oral Implants Res 2000, 11:273-278.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 273-278
    • Nocini, P.F.1    Albanese, M.2    Fior, A.3    De Santis, D.4
  • 12
    • 0037822200 scopus 로고    scopus 로고
    • Maxillary sinus floor augmentation with autogenous bone grafts to enable placement of SLA-surfaced implants: preliminary results after 15-40 months
    • Stricker A., Voss P.J., Gutwald R., Schramm A., Schmelzeisen R. Maxillary sinus floor augmentation with autogenous bone grafts to enable placement of SLA-surfaced implants: preliminary results after 15-40 months. Clin Oral Implants Res 2003, 14:207-212.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 207-212
    • Stricker, A.1    Voss, P.J.2    Gutwald, R.3    Schramm, A.4    Schmelzeisen, R.5
  • 14
    • 23944466723 scopus 로고    scopus 로고
    • Stability of autogenous bone grafts after sinus lift procedures: a comparative study between anterior and posterior aspects of the iliac crest and an intraoral donor site
    • Thorwarth M., Srour S., Felszeghy E., Kessler P., Schultze-Mosgau S., Schlegel K.A. Stability of autogenous bone grafts after sinus lift procedures: a comparative study between anterior and posterior aspects of the iliac crest and an intraoral donor site. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005, 100:278-284.
    • (2005) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.100 , pp. 278-284
    • Thorwarth, M.1    Srour, S.2    Felszeghy, E.3    Kessler, P.4    Schultze-Mosgau, S.5    Schlegel, K.A.6
  • 16
    • 33748290174 scopus 로고    scopus 로고
    • Influence of forces on peri-implant bone
    • Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res 2006, 17:8-18.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 8-18
    • Isidor, F.1
  • 17
    • 85016033318 scopus 로고
    • Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling
    • Hoshaw S.J., Brunski J.B., Cochran G.V. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994, 9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.3
  • 18
    • 0033073260 scopus 로고    scopus 로고
    • Bone classification: clinical-histomorphometric comparison
    • Trisi P., Rao W. Bone classification: clinical-histomorphometric comparison. Clin Oral Implants Res 1999, 10:1-7.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 1-7
    • Trisi, P.1    Rao, W.2
  • 19
    • 2342665713 scopus 로고    scopus 로고
    • Implant biomechanics in grafted sinus: a finite element analysis
    • Fanuscu M.I., Vu H.V., Poncelet B. Implant biomechanics in grafted sinus: a finite element analysis. J Oral Implantol 2004, 30:59-68.
    • (2004) J Oral Implantol , vol.30 , pp. 59-68
    • Fanuscu, M.I.1    Vu, H.V.2    Poncelet, B.3
  • 20
    • 0025493944 scopus 로고
    • The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: a prospective multicenter study on 558 fixtures
    • van Steenberghe D., Lekholm U., Bolender C., Folmer T., Henry P., Herrman I., et al. The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: a prospective multicenter study on 558 fixtures. Int J Oral Maxillofac Implants 1990, 5:272-281.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 272-281
    • van Steenberghe, D.1    Lekholm, U.2    Bolender, C.3    Folmer, T.4    Henry, P.5    Herrman, I.6
  • 21
    • 0031112208 scopus 로고    scopus 로고
    • Influence of implant diameters on the integration of screw implants. An experimental study in rabbits
    • Ivanoff C.J., Sennerby L., Johansson C., Rangert B., Lekholm U. Influence of implant diameters on the integration of screw implants. An experimental study in rabbits. Int J Oral Maxillofac Surg 1997, 26:141-148.
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 141-148
    • Ivanoff, C.J.1    Sennerby, L.2    Johansson, C.3    Rangert, B.4    Lekholm, U.5
  • 22
    • 0025060760 scopus 로고
    • The effect of diameter and length of hydroxylapatite-coated dental implants on ultimate pullout force in dog alveolar bone
    • Block M.S., Delgado A., Fontenot M.G. The effect of diameter and length of hydroxylapatite-coated dental implants on ultimate pullout force in dog alveolar bone. J Oral Maxillofac Surg 1990, 48:174-178.
    • (1990) J Oral Maxillofac Surg , vol.48 , pp. 174-178
    • Block, M.S.1    Delgado, A.2    Fontenot, M.G.3
  • 23
    • 0031299758 scopus 로고    scopus 로고
    • Implant diameter and bone density: effect on initial stability and pull-out resistance
    • Kido H., Schulz E.E., Kumar A., Lozada J., Saha S. Implant diameter and bone density: effect on initial stability and pull-out resistance. J Oral Implantol 1997, 23:163-169.
    • (1997) J Oral Implantol , vol.23 , pp. 163-169
    • Kido, H.1    Schulz, E.E.2    Kumar, A.3    Lozada, J.4    Saha, S.5
  • 24
    • 0035554509 scopus 로고    scopus 로고
    • A 48-month multicentric clinical investigation: implant design and survival
    • Morris H.F., Winkler S., Ochi S. A 48-month multicentric clinical investigation: implant design and survival. J Oral Implantol 2001, 27:180-186.
    • (2001) J Oral Implantol , vol.27 , pp. 180-186
    • Morris, H.F.1    Winkler, S.2    Ochi, S.3
  • 25
    • 0031201966 scopus 로고    scopus 로고
    • Clinical evaluation of hydroxyapatite-coated titanium plasma-sprayed and titanium plasma-sprayed cylinder dental implants: a preliminary report
    • Jones J.D., Saigusa M., Van Sickels J.E., Tiner B.D., Gardner W.A. Clinical evaluation of hydroxyapatite-coated titanium plasma-sprayed and titanium plasma-sprayed cylinder dental implants: a preliminary report. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1997, 84:137-141.
    • (1997) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.84 , pp. 137-141
    • Jones, J.D.1    Saigusa, M.2    Van Sickels, J.E.3    Tiner, B.D.4    Gardner, W.A.5
  • 26
    • 0041418181 scopus 로고    scopus 로고
    • Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimentional finite element analysis
    • Tada S., Stegaroiu R., Kitamura E., Miyakawa O., Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimentional finite element analysis. Int J Oral Maxillofac Implants 2003, 18:357-368.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 357-368
    • Tada, S.1    Stegaroiu, R.2    Kitamura, E.3    Miyakawa, O.4    Kusakari, H.5
  • 27
    • 26944455656 scopus 로고    scopus 로고
    • Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis
    • Petrie C.S., Williams J.L. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. Clin Oral Implants Res 2005, 16:486-494.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 486-494
    • Petrie, C.S.1    Williams, J.L.2
  • 28
    • 0004520883 scopus 로고    scopus 로고
    • The properties of titanium
    • Thieme, Stuttgart, A. Schroeder, F. Sutter, D. Buser, G. Krekeler (Eds.)
    • Steinemann S. The properties of titanium. Oral implantology. Basics, ITI hollow cylinder system 1996, 37-58. Thieme, Stuttgart. 2nd ed. A. Schroeder, F. Sutter, D. Buser, G. Krekeler (Eds.).
    • (1996) Oral implantology. Basics, ITI hollow cylinder system , pp. 37-58
    • Steinemann, S.1
  • 29
    • 0018137364 scopus 로고
    • Mechanical properties and composition of cortical bone
    • Carter D.R., Spengler D.M. Mechanical properties and composition of cortical bone. Clin Orthop 1978, 135:192-217.
    • (1978) Clin Orthop , vol.135 , pp. 192-217
    • Carter, D.R.1    Spengler, D.M.2
  • 30
    • 0034303223 scopus 로고    scopus 로고
    • Anisotropic elastic properties of cancellous bone from a human edentulous mandible
    • O'Mahony A.M., Williams J.L., Katz J.O., Spencer P. Anisotropic elastic properties of cancellous bone from a human edentulous mandible. Clin Oral Implants Res 2000, 11:415-421.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 415-421
    • O'Mahony, A.M.1    Williams, J.L.2    Katz, J.O.3    Spencer, P.4
  • 31
    • 0027551874 scopus 로고
    • Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements
    • Rho J.Y., Ashman R.B., Turner C.H. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech 1993, 26:111-119.
    • (1993) J Biomech , vol.26 , pp. 111-119
    • Rho, J.Y.1    Ashman, R.B.2    Turner, C.H.3
  • 32
    • 0029175465 scopus 로고
    • Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses
    • van Zyl P.P., Grundling N.L., Jooste C.H., Terblanche E. Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses. Int J Oral Maxillofac Implants 1995, 10:51-57.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 51-57
    • van Zyl, P.P.1    Grundling, N.L.2    Jooste, C.H.3    Terblanche, E.4
  • 33
    • 1842840921 scopus 로고    scopus 로고
    • A 2003 update of bone physiology and Wolff's Law for clinicians
    • Frost H.M. A 2003 update of bone physiology and Wolff's Law for clinicians. Angle Orthod 2004, 74:3-15.
    • (2004) Angle Orthod , vol.74 , pp. 3-15
    • Frost, H.M.1
  • 34
    • 0033124101 scopus 로고    scopus 로고
    • Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling
    • Stanford C.M., Brand R.A. Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling. J Prosthet Dent 1999, 81:553-561.
    • (1999) J Prosthet Dent , vol.81 , pp. 553-561
    • Stanford, C.M.1    Brand, R.A.2
  • 35
    • 0035315830 scopus 로고    scopus 로고
    • Biological reactions of alveolar bone to orthodontic loading of oral implants
    • Melsen B., Lang N.P. Biological reactions of alveolar bone to orthodontic loading of oral implants. Clin Oral Implants Res 2001, 12:144-152.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 144-152
    • Melsen, B.1    Lang, N.P.2
  • 36
    • 0027830480 scopus 로고
    • A histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: a pilot study
    • Piattelli A., Ruggeri A., Franchi M., Romasco N., Trisi P. A histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: a pilot study. J Oral Implantol 1993, 19:314-320.
    • (1993) J Oral Implantol , vol.19 , pp. 314-320
    • Piattelli, A.1    Ruggeri, A.2    Franchi, M.3    Romasco, N.4    Trisi, P.5
  • 37
    • 23844502801 scopus 로고    scopus 로고
    • Bone reactions to longstanding functional load at implants: an experimental study in dogs
    • Berglundh T., Abrahamsson I., Lindhe J. Bone reactions to longstanding functional load at implants: an experimental study in dogs. J Clin Periodontol 2005, 32:925-932.
    • (2005) J Clin Periodontol , vol.32 , pp. 925-932
    • Berglundh, T.1    Abrahamsson, I.2    Lindhe, J.3
  • 38
    • 33845506823 scopus 로고    scopus 로고
    • Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification
    • Al-Sukhun J., Kelleway J., Helenius M. Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification. J Biomed Mater Res A 2007, 80:234-246.
    • (2007) J Biomed Mater Res A , vol.80 , pp. 234-246
    • Al-Sukhun, J.1    Kelleway, J.2    Helenius, M.3
  • 39
    • 34547260080 scopus 로고    scopus 로고
    • Biomechanics of the mandible: part II. Development of a 3-dimensional finite element model to study mandibular functional deformation in subjects treated with dental implants
    • Al-Sukhun J., Kelleway J. Biomechanics of the mandible: part II. Development of a 3-dimensional finite element model to study mandibular functional deformation in subjects treated with dental implants. Int J Oral Maxillofac Implants 2007, 22:455-466.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 455-466
    • Al-Sukhun, J.1    Kelleway, J.2
  • 40
    • 18044403181 scopus 로고    scopus 로고
    • The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study
    • Duyck J., Rønold H.J., Van Oosterwyck H., Naert I., Vander Sloten J., Ellingsen J.E. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Implants Res 2001, 12:207-218.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 207-218
    • Duyck, J.1    Rønold, H.J.2    Van Oosterwyck, H.3    Naert, I.4    Vander Sloten, J.5    Ellingsen, J.E.6
  • 41
    • 0142037290 scopus 로고    scopus 로고
    • Biomechanics of bone
    • Elsevier, Amsterdam, J.P. Bilezikian, L.G. Raisz, G.A. Rodan (Eds.)
    • Cullinane D.M., Einhorn T.A. Biomechanics of bone. Principles of bone biology, vol. 1 2002, 17-32. Elsevier, Amsterdam. 2nd ed. J.P. Bilezikian, L.G. Raisz, G.A. Rodan (Eds.).
    • (2002) Principles of bone biology, vol. 1 , pp. 17-32
    • Cullinane, D.M.1    Einhorn, T.A.2
  • 42
    • 0036974710 scopus 로고    scopus 로고
    • Tree-dimensional finite element analysis of implant stability in the atrophic posterior maxilla
    • Tepper G., Hass R., Zechner W., Krach W., Watzek G. Tree-dimensional finite element analysis of implant stability in the atrophic posterior maxilla. Clin Oral Implants Res 2002, 13:657-665.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 657-665
    • Tepper, G.1    Hass, R.2    Zechner, W.3    Krach, W.4    Watzek, G.5
  • 43
    • 16344386568 scopus 로고    scopus 로고
    • Influence of marginal bone resorption on stress around an implant-a three-dimensional finite element analysis
    • Kitamura E., Stegaroiu R., Nomura S., Miyakawa O. Influence of marginal bone resorption on stress around an implant-a three-dimensional finite element analysis. J Oral Rehabil 2005, 32:279-286.
    • (2005) J Oral Rehabil , vol.32 , pp. 279-286
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 44
    • 0031612903 scopus 로고    scopus 로고
    • Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis
    • Stegaroiu R., Sato T., Kusakari H., Miyakawa O Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants 1998, 13:82-90.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 82-90
    • Stegaroiu, R.1    Sato, T.2    Kusakari, H.3    Miyakawa, O.4
  • 45
    • 32644448428 scopus 로고    scopus 로고
    • Peri-implant stress analysis in simulation models with or without trabecular bone structure
    • Stegaroiu R., Watanabe N., Tanaka M., Ejiri S., Nomura S., Miyakawa O. Peri-implant stress analysis in simulation models with or without trabecular bone structure. Int J Prosthodont 2006, 19:40-42.
    • (2006) Int J Prosthodont , vol.19 , pp. 40-42
    • Stegaroiu, R.1    Watanabe, N.2    Tanaka, M.3    Ejiri, S.4    Nomura, S.5    Miyakawa, O.6
  • 46
    • 85175512057 scopus 로고    scopus 로고
    • Isotropic heterogeneous FEM model vs isotropic and anisotropic homogeneous models
    • [special issue B #1246]
    • Stegaroiu R., Ejiri S., Kurokawa K., Sato T., Sato Y., Nomura S. Isotropic heterogeneous FEM model vs isotropic and anisotropic homogeneous models. J Dent Res 2008, 87. [special issue B #1246].
    • (2008) J Dent Res , vol.87
    • Stegaroiu, R.1    Ejiri, S.2    Kurokawa, K.3    Sato, T.4    Sato, Y.5    Nomura, S.6
  • 47
    • 40849136266 scopus 로고    scopus 로고
    • Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading
    • Lin C.L., Wang J.C., Ramp L.C., Liu P.R. Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. Int J Oral Maxillofac Implants 2008, 23:57-64.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 57-64
    • Lin, C.L.1    Wang, J.C.2    Ramp, L.C.3    Liu, P.R.4
  • 48
    • 0026084439 scopus 로고
    • The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis
    • Jaffin R.A., Berman C.L. The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. J Periodontol 1991, 62:2-4.
    • (1991) J Periodontol , vol.62 , pp. 2-4
    • Jaffin, R.A.1    Berman, C.L.2
  • 50
    • 7944238609 scopus 로고    scopus 로고
    • Histological evidence of osseointegration in human retrieved fractured hydroxyapatite-coated screw-type implants: a case report
    • Uehara T., Takaoka K., Ito K. Histological evidence of osseointegration in human retrieved fractured hydroxyapatite-coated screw-type implants: a case report. Clin Oral Implants Res 2004, 15:540-545.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 540-545
    • Uehara, T.1    Takaoka, K.2    Ito, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.