메뉴 건너뛰기




Volumn 10, Issue 3, 2010, Pages 1798-1809

Study of sodium ion selective electrodes and differential structures with anodized indium tin oxide

Author keywords

Anodic oxidation; Anodized indium tin oxide; EGFET; Sodium ion

Indexed keywords

DIFFERENTIAL STRUCTURE; EGFET; INDIUM TIN OXIDE; MANUFACTURE PROCESS; REFERENCE ELECTRODES; ROOM TEMPERATURE; SELECTIVE ELECTRODES; SODIUM IONS;

EID: 77955508387     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s100301798     Document Type: Article
Times cited : (27)

References (12)
  • 1
    • 0032145775 scopus 로고    scopus 로고
    • Flow injection analysis of potassium using an all-solid-state potassium-selective electrode as a detector
    • Komaba, S.; Arakawa, J.; Seyama, M.; Osaka, T.; Satoh, I.; Nakamura, S. Flow injection analysis of potassium using an all-solid-state potassium-selective electrode as a detector. Talanta 1998, 46, 1293-1297.
    • (1998) Talanta , vol.46 , pp. 1293-1297
    • Komaba, S.1    Arakawa, J.2    Seyama, M.3    Osaka, T.4    Satoh, I.5    Nakamura, S.6
  • 3
    • 0034733911 scopus 로고    scopus 로고
    • Application of an ion-selective field effect transistor with a photocured polymer membrane in nephrology for determination of potassium ions in dialysis solutions and in blood plasma
    • Abramova, N.; Borisov, Y.; Bratov, A.; Gavrilenko, P.; Domínguez, C.; Spiridonov, V.; Suglobova, E. Application of an ion-selective field effect transistor with a photocured polymer membrane in nephrology for determination of potassium ions in dialysis solutions and in blood plasma. Talanta 2000, 52, 533-538.
    • (2000) Talanta , vol.52 , pp. 533-538
    • Abramova, N.1    Borisov, Y.2    Bratov, A.3    Gavrilenko, P.4    Domínguez, C.5    Spiridonov, V.6    Suglobova, E.7
  • 4
    • 3042825092 scopus 로고    scopus 로고
    • Using polypyrrole as the contrast pH detector to fabricate a whole solid-state pH sensing device
    • Pan, C.W.; Chou, J.C.; Kao, I.K.; Sun, T.P.; Hsiung, S.K. Using polypyrrole as the contrast pH detector to fabricate a whole solid-state pH sensing device. IEEE Sens. J. 2003, 3, 164-170.
    • (2003) IEEE Sens. J , vol.3 , pp. 164-170
    • Pan, C.W.1    Chou, J.C.2    Kao, I.K.3    Sun, T.P.4    Hsiung, S.K.5
  • 6
    • 34547867787 scopus 로고    scopus 로고
    • Structure of anodized aluminum oxide extended-gate field-effect transistors on pH sensors
    • Lin, J.L.; Chu, Y.M.; Hsaio, S.H.; Chin, Y.L.; Sun, T.P. Structure of anodized aluminum oxide extended-gate field-effect transistors on pH sensors. Jpn. J. Appl. Phys. 2006, 45, 7999-8004.
    • (2006) Jpn. J. Appl. Phys , vol.45 , pp. 7999-8004
    • Lin, J.L.1    Chu, Y.M.2    Hsaio, S.H.3    Chin, Y.L.4    Sun, T.P.5
  • 7
    • 0035850545 scopus 로고    scopus 로고
    • Hall assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodes
    • Lee, Y.H.; Elizabeth, A.H. Hall assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodes. Anal. Chim. Acta 2001, 433, 25-40.
    • (2001) Anal. Chim. Acta , vol.433 , pp. 25-40
    • Lee, Y.H.1    Elizabeth, A.H.2
  • 8
    • 33645158268 scopus 로고    scopus 로고
    • A new sodium ion selective electrode based on a novel silacrown ether
    • Chandra, S.; Lang, H. A new sodium ion selective electrode based on a novel silacrown ether. Sens. Actuat. B 2006, 114, 849-854.
    • (2006) Sens. Actuat. B , vol.114 , pp. 849-854
    • Chandra, S.1    Lang, H.2
  • 9
    • 63049106203 scopus 로고    scopus 로고
    • Fabrication and stability analysis for sodium ion sensor
    • Chou, J.C.; Huang, Y.P. Fabrication and stability analysis for sodium ion sensor. Sens. Lett. 2008, 6, 920-923.
    • (2008) Sens. Lett , vol.6 , pp. 920-923
    • Chou, J.C.1    Huang, Y.P.2
  • 11
    • 0034583224 scopus 로고    scopus 로고
    • Potentiometric selectivity coefficients of ion-selective electrodes Part I. Inogranic cations
    • Umezawa, Y.; Buhlmann, P.; Umezawa, K.; Tohda, K.; Amemiya, S. Potentiometric selectivity coefficients of ion-selective electrodes Part I. Inogranic cations. Pure Appl. Chem. 2000, 72, 1851-2082.
    • (2000) Pure Appl. Chem , vol.72 , pp. 1851-2082
    • Umezawa, Y.1    Buhlmann, P.2    Umezawa, K.3    Tohda, K.4    Amemiya, S.5
  • 12
    • 38549105511 scopus 로고    scopus 로고
    • Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes
    • Lindner, E.; Umezawa, Y. Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes. Pure Appl. Chem. 2008, 80, 85-104.
    • (2008) Pure Appl. Chem , vol.80 , pp. 85-104
    • Lindner, E.1    Umezawa, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.