메뉴 건너뛰기




Volumn 115, Issue 5, 2010, Pages 702-713

Functional parameters of the left ventricle: Comparison of cardiac MRI and cardiac CT in a large population;Parametri funzionali del ventricolo sinistro: confronto tra cardio-RM e cardio-TC in un'ampia popolazione

Author keywords

Cardiac computed tomography; Cardiac magnetic resonance; Ejection fraction; Left ventricular volumes; Quantitative software

Indexed keywords

CONTRAST MEDIUM; DIAGNOSTIC AGENT; DRUG DERIVATIVE; IOMEPROL; IOPAMIDOL;

EID: 77955472960     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11547-010-0525-0     Document Type: Article
Times cited : (15)

References (29)
  • 1
    • 0021893531 scopus 로고
    • Porgnostic significance of progression of coronary artery disease
    • DOI 10.1016/0002-9149(85)90722-2
    • A. Moise M.G. Bourassa P. Theroux 1985 Prognostic significance of progression of coronary artery disease Am J Cardiol 55 941 946 10.1016/0002-9149(85)90722-2 1:STN:280:DyaL2M7ntFOntw%3D%3D 3157308 (Pubitemid 15085340)
    • (1985) American Journal of Cardiology , vol.55 , Issue.8 , pp. 941-946
    • Moise, A.1    Bourassa, M.G.2    Theroux, P.3
  • 2
    • 0028641172 scopus 로고
    • Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) registry
    • 1:STN:280:DyaK2M%2FoslWjtw%3D%3D 7994804
    • M. Emond M.B. Mock K.B. Davis 1994 Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) registry Circulation 90 2645 2657 1:STN:280:DyaK2M%2FoslWjtw%3D%3D 7994804
    • (1994) Circulation , vol.90 , pp. 2645-2657
    • Emond, M.1    Mock, M.B.2    Davis, K.B.3
  • 3
    • 31544479569 scopus 로고    scopus 로고
    • Left ventricular function studied with MDCT
    • DOI 10.1007/s00330-005-2888-5
    • K.U. Juergens R. Fischbach 2006 Left ventricular function studied with MDCT Eur Radiol 16 342 357 10.1007/s00330-005-2888-5 16132917 (Pubitemid 43153682)
    • (2006) European Radiology , vol.16 , Issue.2 , pp. 342-357
    • Juergens, K.U.1    Fischbach, R.2
  • 4
    • 0019943492 scopus 로고
    • Prognostic value of exercise testing, coronary angiography and left ventriculography 6-8 weeks after myocardial infarction
    • 7094264
    • P.J. de Feyter M.J. van Eenige D.H. Dighton 1982 Prognostic value of exercise testing, coronary angiography and left ventriculography 6-8 weeks after myocardial infarction Circulation 66 527 536 7094264
    • (1982) Circulation , vol.66 , pp. 527-536
    • De Feyter, P.J.1    Van Eenige, M.J.2    Dighton, D.H.3
  • 5
    • 0019186806 scopus 로고
    • Predictors of clinical course, coronary anatomy and left ventricular function after recovery from acute myocardial infarction
    • 1:STN:280:DyaL3M%2Fit12gtQ%3D%3D 6968257
    • G.J. Taylor J.O. Humphries E.D. Mellits 1980 Predictors of clinical course, coronary anatomy and left ventricular function after recovery from acute myocardial infarction Circulation 62 960 970 1:STN:280:DyaL3M%2Fit12gtQ%3D%3D 6968257
    • (1980) Circulation , vol.62 , pp. 960-970
    • Taylor, G.J.1    Humphries, J.O.2    Mellits, E.D.3
  • 6
    • 0023219810 scopus 로고
    • Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction
    • 1:STN:280:DyaL2s3ksVOrug%3D%3D 3594774
    • H.D. White R.M. Norris M.A. Brown 1987 Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction Circulation 76 44 51 1:STN:280:DyaL2s3ksVOrug%3D%3D 3594774
    • (1987) Circulation , vol.76 , pp. 44-51
    • White, H.D.1    Norris, R.M.2    Brown, M.A.3
  • 7
    • 0029999099 scopus 로고    scopus 로고
    • Quantitative MR imaging of the heart
    • 1:STN:280:DyaK28zitFamsg%3D%3D 8724567
    • R.M. Peshock D.L. Willett D.E. Sayad 1996 Quantitative MR imaging of the heart Magn Reson Imaging Clin N Am 4 287 305 1:STN:280:DyaK28zitFamsg%3D%3D 8724567
    • (1996) Magn Reson Imaging Clin N Am , vol.4 , pp. 287-305
    • Peshock, R.M.1    Willett, D.L.2    Sayad, D.E.3
  • 8
    • 1842750672 scopus 로고    scopus 로고
    • Imaging of ventricular function by cardiovascular magnetic resonance
    • 10.1007/s11886-004-0065-0 14662098
    • V.K. Rathi R.W. Biedermann 2004 Imaging of ventricular function by cardiovascular magnetic resonance Curr Cardiol Rep 6 55 61 10.1007/s11886-004- 0065-0 14662098
    • (2004) Curr Cardiol Rep , vol.6 , pp. 55-61
    • Rathi, V.K.1    Biedermann, R.W.2
  • 9
    • 33745018811 scopus 로고    scopus 로고
    • Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: Comparison with cine magnetic resonance imaging
    • DOI 10.1007/s00330-006-0169-6
    • B. Belge E. Coche A. Pasquet 2006 Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography. Comparison with cine magnetic resonance imaging Eur Radiol 16 1424 1433 10.1007/s00330-006-0169-6 16518654 (Pubitemid 43871813)
    • (2006) European Radiology , vol.16 , Issue.7 , pp. 1424-1433
    • Belge, B.1    Coche, E.2    Pasquet, A.3    Vanoverschelde, J.-L.J.4    Gerber, B.L.5
  • 10
    • 49049085232 scopus 로고    scopus 로고
    • Assessment of left ventricular function with 16- and 64-slice multidetector computed tomography
    • 10.1016/j.ejrad.2007.07.022 17826936
    • S. Abbara B.J.W. Chowa A.J. Pena 2008 Assessment of left ventricular function with 16- and 64-slice multidetector computed tomography Eur J Radiol 67 481 48611 10.1016/j.ejrad.2007.07.022 17826936
    • (2008) Eur J Radiol , vol.67 , pp. 481-48611
    • Abbara, S.1    Chowa, B.J.W.2    Pena, A.J.3
  • 11
    • 45149083745 scopus 로고    scopus 로고
    • Assessment of left ventricular unction: Comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function
    • 10.1007/s10554-007-9252-6 17701445
    • D. Bansal R.M. Singh M. Sarkar 2008 Assessment of left ventricular unction: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function Int J Cardiovasc Imaging 24 317 325 10.1007/s10554-007-9252-6 17701445
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 317-325
    • Bansal, D.1    Singh, R.M.2    Sarkar, M.3
  • 13
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular size and function: Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    • DOI 10.1161/CIRCULATIONAHA.106.626143, PII 0000301720060815000009
    • L. Sugeng V. Mor-Avi L. Weinert 2006 Quantitative Assessment of Left Ventricular Size and Function. Side-by-Side Comparison of Real-Time Three-Dimensional Echocardiography and Computed Tomography With Magnetic Resonance Reference Circulation 114 654 661 10.1161/CIRCULATIONAHA.106.626143 16894035 (Pubitemid 44252307)
    • (2006) Circulation , vol.114 , Issue.7 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3    Niel, J.4    Ebner, C.5    Steringer-Mascherbauer, R.6    Schmidt, F.7    Galuschky, C.8    Schummers, G.9    Lang, R.M.10    Nesser, H.-J.11
  • 15
    • 52049107375 scopus 로고    scopus 로고
    • Global left-ventricular function assessment using dual-source multidetector CT: Effect of improved temporal resolution on ventricular volume measurement
    • 10.1007/s00330-008-0982-1 18449547
    • M. Puesken R. Fischbach M. Wenker 2008 Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement Eur Radiol 18 2087 2094 10.1007/s00330-008-0982-1 18449547
    • (2008) Eur Radiol , vol.18 , pp. 2087-2094
    • Puesken, M.1    Fischbach, R.2    Wenker, M.3
  • 16
    • 46849116002 scopus 로고    scopus 로고
    • Left ventricular ejection fraction using 64-slice CT coronary angiography and new evaluation software: Initial experience
    • DOI 10.1259/bjr/54748900
    • M.S. Krishnam A. Tomasian S.G. Ruehm 2008 Left ventricular ejection fraction using 64-slice CT coronary angiography and new evaluation software: initial experience Br J Radiol 81 450 455 10.1259/bjr/54748900 1:STN:280:DC%2BD1czitFyitg%3D%3D 18347027 (Pubitemid 351957755)
    • (2008) British Journal of Radiology , vol.81 , Issue.966 , pp. 450-455
    • Krishnam, M.S.1    Tomasian, A.2    Iv, M.3    Ruehm, S.G.4    Saleh, R.5    Panknin, C.6    Goldin, J.G.7
  • 17
    • 39049143833 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: Initial findings
    • DOI 10.1007/s00330-007-0767-y
    • S. Busch T.R.C. Johnson J. Wintersperger 2008 Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings Eur Radiol 18 570 575 10.1007/s00330-007- 0767-y 1:STN:280:DC%2BD1c7gtF2qsw%3D%3D 17909817 (Pubitemid 351248185)
    • (2008) European Radiology , vol.18 , Issue.3 , pp. 570-575
    • Busch, S.1    Johnson, T.R.C.2    Wintersperger, B.J.3    Minaifar, N.4    Bhargava, A.5    Rist, C.6    Reiser, M.F.7    Becker, C.8    Nikolaou, K.9
  • 19
    • 37349049968 scopus 로고    scopus 로고
    • Safety of magnetic resonance imaging in patients with cardiovascular devices: An American heart association scientific statement from the committee on diagnostic and interventional cardiac catheterization, council on clinical cardiology, and the council on cardiovascular radiology and intervention
    • DOI 10.1161/CIRCULATIONAHA.107.187256
    • G.N. Levine A.S. Gomes A.E. Arai 2007 Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization Circulation 116 2878 2891 10.1161/CIRCULATIONAHA.107.187256 18025533 (Pubitemid 350291228)
    • (2007) Circulation , vol.116 , Issue.24 , pp. 2878-2891
    • Levine, G.N.1    Gomes, A.S.2    Arai, A.E.3    Bluemke, D.A.4    Flamm, S.D.5    Kanal, E.6    Manning, W.J.7    Martin, E.T.8    Smith, J.M.9    Wilke, N.10    Shellock, F.S.11
  • 20
    • 53249100687 scopus 로고    scopus 로고
    • MRI Safety Update: 2008, Part 2, Screening patients for MRI
    • F.G. Shellock A. Spinazzi 2008 MRI Safety Update: 2008, Part 2, Screening patients for MRI AJR Am J Roentgenol 191 12 21
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 12-21
    • Shellock, F.G.1    Spinazzi, A.2
  • 23
    • 58249103002 scopus 로고    scopus 로고
    • Left ventricular anatomy: Its nomenclature, segmentation, and planes of imaging
    • 10.1002/ca.20646 18521951
    • J.B. Partridge R.H. Anderson 2009 Left ventricular anatomy: its nomenclature, segmentation, and planes of imaging Clinical Anatomy 22 77 84 10.1002/ca.20646 18521951
    • (2009) Clinical Anatomy , vol.22 , pp. 77-84
    • Partridge, J.B.1    Anderson, R.H.2
  • 24
    • 38849152269 scopus 로고    scopus 로고
    • Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method
    • DOI 10.1016/j.ejrad.2007.03.031, PII S0720048X07001866
    • K. Hergan A. Schuster J. Frühwald 2008 Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method Eur J Radiol 65 270 278 10.1016/j.ejrad.2007.03.031 17498903 (Pubitemid 351187962)
    • (2008) European Journal of Radiology , vol.65 , Issue.2 , pp. 270-278
    • Hergan, K.1    Schuster, A.2    Fruhwald, J.3    Mair, M.4    Burger, R.5    Topker, M.6
  • 25
    • 0033301605 scopus 로고    scopus 로고
    • Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging
    • 10.3109/10976649909080829 1:STN:280:DC%2BD3MrgtFahsA%3D%3D 11550343
    • C.H. Lorenz E.S. Walker V.L. Morgan 1999 Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging J Cardiovasc Magn Reson 1 7 21 10.3109/10976649909080829 1:STN:280:DC%2BD3MrgtFahsA%3D%3D 11550343
    • (1999) J Cardiovasc Magn Reson , vol.1 , pp. 7-21
    • Lorenz, C.H.1    Walker, E.S.2    Morgan, V.L.3
  • 26
    • 0036206953 scopus 로고    scopus 로고
    • MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters
    • 10.1148/radiol.2231010235 11930076
    • S. Miller O.P. Simonetti J. Carr 2002 MR imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters Radiology 223 263 269 10.1148/radiol.2231010235 11930076
    • (2002) Radiology , vol.223 , pp. 263-269
    • Miller, S.1    Simonetti, O.P.2    Carr, J.3
  • 27
    • 33745127684 scopus 로고    scopus 로고
    • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection
    • 10.1148/radiol.2401050471 16793980
    • R.J. van Geuns T. Baks E.H. Gronenschild 2006 Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection Radiology 240 215 221 10.1148/radiol.2401050471 16793980
    • (2006) Radiology , vol.240 , pp. 215-221
    • Van Geuns, R.J.1    Baks, T.2    Gronenschild, E.H.3
  • 28
    • 1542373642 scopus 로고    scopus 로고
    • Impact of Papillary Muscles in Ventricular Volume and Ejection Fraction Assessment by Cardiovascular Magnetic Resonance
    • DOI 10.1081/JCMR-120027800
    • B. Sievers S. Kirchberg A. Bakan 2004 Impact of papillary muscles in ventricular volume and ejection fraction assessment by cardiovascular magnetic resonance J Cardiovasc Magn Reson 6 9 16 10.1081/JCMR-120027800 15054924 (Pubitemid 38316423)
    • (2004) Journal of Cardiovascular Magnetic Resonance , vol.6 , Issue.1 , pp. 9-16
    • Sievers, B.1    Kirchberg, S.2    Bakan, A.3    Franken, U.4    Trappe, H.-J.5
  • 29
    • 33749061448 scopus 로고    scopus 로고
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group
    • 10.1016/j.jacc.2006.07.003 17010819, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology
    • R.C. Hendel M.R. Patel C.M. Kramer 2006 ACCF/ACR/SCCT/SCMR/ASNC/NASCI/ SCAI/SIR appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology J Am Coll Cardiol 48 1475 1497 10.1016/j.jacc.2006.07.003 17010819
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1475-1497
    • Hendel, R.C.1    Patel, M.R.2    Kramer, C.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.