메뉴 건너뛰기




Volumn 130, Issue 7, 2010, Pages 889-895

Navigated scaphoid screw placement using customized scaphoid splint: An anatomical study

Author keywords

3D imaging; Accuracy; CAS; Computer assisted surgery; Internal fixation; Scaphoid fracture; Wrist fracture

Indexed keywords

ARTICLE; BONE SCREW; CADAVER; CARPAL BONE; COMPUTER ASSISTED SURGERY; DIAGNOSTIC IMAGING; FLUOROSCOPY; HUMAN; HUMAN TISSUE; OSTEOSYNTHESIS; PRIORITY JOURNAL; SCAPHOID FRACTURE; SPLINT; SURGICAL ANATOMY; THREE DIMENSIONAL IMAGING; WRIST FRACTURE;

EID: 77955469628     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-010-1044-0     Document Type: Article
Times cited : (21)

References (22)
  • 1
    • 0024232058 scopus 로고
    • Technical factors related to Herbert screw fixation
    • 10.1016/0363-5023(88)90267-5 1:STN:280:DyaL1M7ktVahsw%3D%3D 3225417
    • BD Adams WF Blair DS Reagan AB Grundberg 1988 Technical factors related to Herbert screw fixation J Hand Surg Am 13 893 899 10.1016/0363-5023(88)90267-5 1:STN:280:DyaL1M7ktVahsw%3D%3D 3225417
    • (1988) J Hand Surg Am , vol.13 , pp. 893-899
    • Adams, B.D.1    Blair, W.F.2    Reagan, D.S.3    Grundberg, A.B.4
  • 2
    • 0032459908 scopus 로고    scopus 로고
    • Measurement of the scaphoid humpback deformity using longitudinal computed tomography: Intra- and interobserver variability using various measurement techniques
    • 10.1016/S0363-5023(98)80093-2 1:STN:280:DyaK1c7ot1WgsQ%3D%3D 9523959
    • GI Bain JD Bennett JC MacDermid GP Slethaug RS Richards JH Roth 1998 Measurement of the scaphoid humpback deformity using longitudinal computed tomography: intra- and interobserver variability using various measurement techniques J Hand Surg Am 23 76 81 10.1016/S0363-5023(98)80093-2 1:STN:280:DyaK1c7ot1WgsQ%3D%3D 9523959
    • (1998) J Hand Surg Am , vol.23 , pp. 76-81
    • Bain, G.I.1    Bennett, J.D.2    MacDermid, J.C.3    Slethaug, G.P.4    Richards, R.S.5    Roth, J.H.6
  • 3
    • 36548998799 scopus 로고    scopus 로고
    • Reference marker stability in computer aided orthopedic surgery: A biomechanical study in artificial bone and cadavers
    • 1:STN:280:DC%2BD2sjis1Gjtg%3D%3D 18057564
    • M Citak TN Board Y Sun V Look C Krettek T Hufner D Kendoff 2007 Reference marker stability in computer aided orthopedic surgery: a biomechanical study in artificial bone and cadavers Technol Health Care 15 407 414 1:STN:280:DC%2BD2sjis1Gjtg%3D%3D 18057564
    • (2007) Technol Health Care , vol.15 , pp. 407-414
    • Citak, M.1    Board, T.N.2    Sun, Y.3    Look, V.4    Krettek, C.5    Hufner, T.6    Kendoff, D.7
  • 4
    • 33750059183 scopus 로고    scopus 로고
    • 3D navigation
    • DOI 10.1080/10929080600890015, PII PG213V0K2G601L04
    • M Citak T Hufner J Geerling M Kfuri Jr A Gansslen V Look D Kendoff C Krettek 2006 Navigated percutaneous pelvic sacroiliac screw fixation: experimental comparison of accuracy between fluoroscopy and Iso-C3D navigation Comput Aided Surg 11 209 213 10.1080/10929080600890015 1:STN:280: DC%2BD28nis1egtA%3D%3D 17060079 (Pubitemid 44577990)
    • (2006) Computer Aided Surgery , vol.11 , Issue.4 , pp. 209-213
    • Citak, M.1    Hufner, T.2    Geerling, J.3    Kfuri Jr., M.4    Gansslen, A.5    Look, V.6    Kendoff, D.7    Krettek, C.8
  • 5
    • 34147164687 scopus 로고    scopus 로고
    • 3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions
    • DOI 10.1302/0301-620X.89B3.18424
    • M Citak D Kendoff M Kfuri Jr A Pearle C Krettek T Hufner 2007 Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study J Bone Joint Surg Br 89 323 326 10.1302/0301-620X.89B3.18424 1:STN:280:DC%2BD2s7ls1WmtQ%3D%3D 17356142 (Pubitemid 46563906)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.3 , pp. 323-326
    • Citak, M.1    Kendoff, D.2    Kfuri Jr., M.3    Pearle, A.4    Krettek, C.5    Hufner, T.6
  • 6
    • 47249160674 scopus 로고    scopus 로고
    • The influence of metal artifacts on navigation and the reduction of artifacts by the use of polyether-ether-ketone
    • 1:STN:280:DC%2BD1cvksVyhsA%3D%3D 18622798
    • M Citak D Kendoff T Wanich V Look V Stuber J Geerling C Krettek T Hufner 2008 The influence of metal artifacts on navigation and the reduction of artifacts by the use of polyether-ether-ketone Comput Aided Surg 13 233 239 1:STN:280:DC%2BD1cvksVyhsA%3D%3D 18622798
    • (2008) Comput Aided Surg , vol.13 , pp. 233-239
    • Citak, M.1    Kendoff, D.2    Wanich, T.3    Look, V.4    Stuber, V.5    Geerling, J.6    Krettek, C.7    Hufner, T.8
  • 7
    • 33845462890 scopus 로고    scopus 로고
    • The influence of distance on registration in ISO-C-3D navigation: A source of error in ISO-C-3D navigation
    • 1:STN:280:DC%2BD28jht1WksA%3D%3D 17148859
    • M Citak D Kendoff T Wanich A Pearle R Singhai C Krettek T Hufner 2006 The influence of distance on registration in ISO-C-3D navigation: a source of error in ISO-C-3D navigation Technol Health Care 14 473 478 1:STN:280: DC%2BD28jht1WksA%3D%3D 17148859
    • (2006) Technol Health Care , vol.14 , pp. 473-478
    • Citak, M.1    Kendoff, D.2    Wanich, T.3    Pearle, A.4    Singhai, R.5    Krettek, C.6    Hufner, T.7
  • 8
    • 26044460918 scopus 로고    scopus 로고
    • Should acute scaphoid fractures be fixed? A randomized controlled trial
    • DOI 10.2106/JBJS.D.02305
    • JJ Dias CJ Wildin B Bhowal JR Thompson 2005 Should acute scaphoid fractures be fixed? A randomized controlled trial J Bone Joint Surg Am 87 2160 2168 10.2106/JBJS.D.02305 1:STN:280:DC%2BD2MrivFGqtg%3D%3D 16203878 (Pubitemid 41407538)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.10 , pp. 2160-2168
    • Dias, J.J.1    Wildin, C.J.2    Bhowal, B.3    Thompson, J.R.4
  • 9
    • 33644653307 scopus 로고    scopus 로고
    • Screw fixation of scaphoid fractures: A biomechanical assessment of screw length and screw augmentation
    • DOI 10.1016/j.jhsa.2005.09.014, PII S0363502305007495
    • SD Dodds MM Panjabi JF Slade 3rd 2006 Screw fixation of scaphoid fractures: a biomechanical assessment of screw length and screw augmentation J Hand Surg Am 31 405 413 10.1016/j.jhsa.2005.09.014 16516734 (Pubitemid 43324934)
    • (2006) Journal of Hand Surgery , vol.31 , Issue.3 , pp. 405-413
    • Dodds, S.D.1    Panjabi, M.M.2    Slade III, J.F.3
  • 10
    • 0026521841 scopus 로고
    • Computerized tomography diagnosis of scaphoid fracture and pseudarthrosis in comparison with roentgen image
    • 1:STN:280:DyaK383lvVOlsQ%3D%3D 1582612
    • R Frahm K Lowka P Vinee 1992 Computerized tomography diagnosis of scaphoid fracture and pseudarthrosis in comparison with roentgen image Handchir Mikrochir Plast Chir 24 62 66 1:STN:280:DyaK383lvVOlsQ%3D%3D 1582612
    • (1992) Handchir Mikrochir Plast Chir , vol.24 , pp. 62-66
    • Frahm, R.1    Lowka, K.2    Vinee, P.3
  • 11
    • 33748079472 scopus 로고    scopus 로고
    • Does computer-assisted spine surgery reduce intraoperative radiation doses?
    • DOI 10.1097/01.brs.0000229250.69369.ac, PII 0000763220060801000022
    • FT Gebhard MD Kraus E Schneider UC Liener L Kinzl M Arand 2006 Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31 2024 2027 10.1097/01.brs.0000229250.69369.ac 16924222 (discussion 2028) (Pubitemid 44297785)
    • (2006) Spine , vol.31 , Issue.17 , pp. 2024-2027
    • Gebhard, F.T.1    Kraus, M.D.2    Schneider, E.3    Liener, U.C.4    Kinzl, L.5    Arand, M.6
  • 12
    • 0026668594 scopus 로고
    • The Herbert bone screw: A ten year perspective
    • 10.1016/S0266-7681(05)80265-7 1:STN:280:DyaK3s%2FhvVekuw%3D%3D 1402269
    • TJ Herbert WE Fisher AW Leicester 1992 The Herbert bone screw: a ten year perspective J Hand Surg Br 17 415 419 10.1016/S0266-7681(05)80265-7 1:STN:280:DyaK3s%2FhvVekuw%3D%3D 1402269
    • (1992) J Hand Surg Br , vol.17 , pp. 415-419
    • Herbert, T.J.1    Fisher, W.E.2    Leicester, A.W.3
  • 13
    • 20644431782 scopus 로고    scopus 로고
    • Accuracy study of computer-assisted drilling: The effect of bone density, drill bit characteristics, and use of a mechanical guide
    • 1:STN:280:DC%2BD2M3ovV2nuw%3D%3D 15891540
    • T Hufner J Geerling G Oldag M Richter M Kfuri Jr T Pohlemann C Krettek 2005 Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide J Orthop Trauma 19 317 322 1:STN:280:DC%2BD2M3ovV2nuw%3D%3D 15891540
    • (2005) J Orthop Trauma , vol.19 , pp. 317-322
    • Hufner, T.1    Geerling, J.2    Oldag, G.3    Richter, M.4    Kfuri Jr., M.5    Pohlemann, T.6    Krettek, C.7
  • 15
    • 67649226406 scopus 로고    scopus 로고
    • Intraoperative 3D imaging: Value and consequences in 248 cases
    • 10.1097/TA.0b013e31815ede5d 19131832
    • D Kendoff M Citak MJ Gardner T Stubig C Krettek T Hufner 2009 Intraoperative 3D imaging: value and consequences in 248 cases J Trauma 66 232 238 10.1097/TA.0b013e31815ede5d 19131832
    • (2009) J Trauma , vol.66 , pp. 232-238
    • Kendoff, D.1    Citak, M.2    Gardner, M.J.3    Stubig, T.4    Krettek, C.5    Hufner, T.6
  • 16
    • 4544356560 scopus 로고    scopus 로고
    • 3D imaging with an isocentric mobile C-arm. Comparison of image quality with spiral CT
    • DOI 10.1007/s00330-004-2316-2
    • D Kotsianos S Wirth T Fischer E Euler C Rock U Linsenmaier KJ Pfeifer M Reiser 2004 3D imaging with an isocentric mobile C-arm comparison of image quality with spiral CT Eur Radiol 14 1590 1595 10.1007/s00330-004-2316-2 15057563 (Pubitemid 39232888)
    • (2004) European Radiology , vol.14 , Issue.9 , pp. 1590-1595
    • Kotsianos, D.1    Wirth, S.2    Fischer, T.3    Euler, E.4    Rock, C.5    Linsenmaier, U.6    Pfeifer, K.J.7    Reiser, M.8
  • 17
    • 45949109905 scopus 로고    scopus 로고
    • Kirschner wire placement in scaphoid bones using fluoroscopic navigation: A cadaver study comparing conventional techniques with navigation
    • 18433080
    • PA Liverneaux A Gherissi MB Stefanelli 2008 Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation Int J Med Robot 4 165 173 18433080
    • (2008) Int J Med Robot , vol.4 , pp. 165-173
    • Liverneaux, P.A.1    Gherissi, A.2    Stefanelli, M.B.3
  • 18
    • 0037267725 scopus 로고    scopus 로고
    • Central placement of the screw in simulated fractures of the scaphoid waist: A biomechanical study
    • 12533575
    • WV McCallister J Knight R Kaliappan TE Trumble 2003 Central placement of the screw in simulated fractures of the scaphoid waist: a biomechanical study J Bone Joint Surg Am 85-A 72 77 12533575
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 72-77
    • McCallister, W.V.1    Knight, J.2    Kaliappan, R.3    Trumble, T.E.4
  • 19
    • 0024229201 scopus 로고
    • Scaphoid fractures treated by Herbert screw fixation
    • 1:STN:280:DyaL1M3lslSntw%3D%3D 3249149
    • R Moran J Curtin 1988 Scaphoid fractures treated by Herbert screw fixation J Hand Surg Br 13 453 455 1:STN:280:DyaL1M3lslSntw%3D%3D 3249149
    • (1988) J Hand Surg Br , vol.13 , pp. 453-455
    • Moran, R.1    Curtin, J.2
  • 20
    • 33645060974 scopus 로고    scopus 로고
    • Postoperative CT-controlled results of renewed osteosynthesis using screw fixation for acute scaphoid fractures
    • 10.1007/s00113-005-1023-z 1:STN:280:DC%2BD287ltF2qug%3D%3D 16270189
    • M Muller ZB Chen A Al Morshidy G Germann M Sauerbier 2006 Postoperative CT-controlled results of renewed osteosynthesis using screw fixation for acute scaphoid fractures Unfallchirurg 109 185 192 10.1007/s00113-005-1023-z 1:STN:280:DC%2BD287ltF2qug%3D%3D 16270189
    • (2006) Unfallchirurg , vol.109 , pp. 185-192
    • Muller, M.1    Chen, Z.B.2    Al Morshidy, A.3    Germann, G.4    Sauerbier, M.5
  • 21
    • 0030042891 scopus 로고    scopus 로고
    • Unrecognized chondral penetration by a Herbert screw in the scaphoid
    • DOI 10.1016/S0363-5023(96)80155-9
    • JA Tumilty DS Squire 1996 Unrecognized chondral penetration by a Herbert screw in the scaphoid J Hand Surg Am 21 66 68 10.1016/S0363-5023(96)80155-9 1:STN:280:DyaK28zntFelsA%3D%3D 8775197 (Pubitemid 26044166)
    • (1996) Journal of Hand Surgery , vol.21 , Issue.1 , pp. 66-68
    • Tumilty, J.A.1    Squire, D.S.2
  • 22
    • 0028892631 scopus 로고
    • Stabilization of the fractured scaphoid under arthroscopic control
    • 1:STN:280:DyaK28%2FhvF2gtw%3D%3D 7566919
    • TL Whipple 1995 Stabilization of the fractured scaphoid under arthroscopic control Orthop Clin North Am 26 749 754 1:STN:280: DyaK28%2FhvF2gtw%3D%3D 7566919
    • (1995) Orthop Clin North Am , vol.26 , pp. 749-754
    • Whipple, T.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.