메뉴 건너뛰기




Volumn 49, Issue 3, 2010, Pages 365-371

COTS Silicon diodes as radiation detectors in proton and heavy charged particle radiotherapy 1

Author keywords

[No Author keywords available]

Indexed keywords

CANCER TREATMENT; CARBON IONS; DIODE DETECTORS; DOSE DEPOSITION; DOSE DISTRIBUTIONS; GERMANY; HEAVY CHARGED PARTICLES; HEAVY-ION THERAPY; HEIDELBERG; HIGH SPATIAL RESOLUTION; PHOTON BEAMS; RADIOTHERAPY FACILITY; SILICON DIODES; SUBMILLIMETERS;

EID: 77955467930     PISSN: 0301634X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00411-010-0299-8     Document Type: Article
Times cited : (16)

References (14)
  • 1
    • 77955471334 scopus 로고
    • Commissioning the TRIUMF proton therapy facility
    • Abstract from the
    • Blackmore EW et al (1994) Commissioning the TRIUMF proton therapy facility (Abstract from the PTCoG meeting 1994)
    • (1994) PTCoG Meeting 1994
    • Blackmore, E.W.1
  • 2
    • 25144492246 scopus 로고    scopus 로고
    • Feasibility study of a personal dosemeter based upon silicon diodes in remote controlling
    • M Caresana, et al. 2005 Feasibility study of a personal dosemeter based upon silicon diodes in remote controlling Rad Prot Dos 114 4 ss469 474
    • (2005) Rad Prot Dos , vol.114 , Issue.4 , pp. 469-474
    • Caresana, M.1
  • 5
    • 0033795042 scopus 로고    scopus 로고
    • General characteristics of the use od silicon diode detectors for clinical dosimetry in proton beams
    • 10.1088/0031-9155/45/9/310
    • E Grusell J Medin 2000 General characteristics of the use od silicon diode detectors for clinical dosimetry in proton beams Phys Med Biol 45 2573 2582 10.1088/0031-9155/45/9/310
    • (2000) Phys Med Biol , vol.45 , pp. 2573-2582
    • Grusell, E.1    Medin, J.2
  • 6
    • 84907110099 scopus 로고
    • Radiation damage induced dose rate non-linearity in an n-type silicon detector
    • 10.3109/02841868409136050
    • E Grusell G Rikner 1984 Radiation damage induced dose rate non-linearity in an n-type silicon detector Acta Radiol Oncol 23 465 469 10.3109/ 02841868409136050
    • (1984) Acta Radiol Oncol , vol.23 , pp. 465-469
    • Grusell, E.1    Rikner, G.2
  • 9
    • 84864173591 scopus 로고    scopus 로고
    • PTW The pdf-file can be found on PTW, LörracherStrae 7, 79115 Freiburg, Germany
    • PTW (2008) Ionizing radiation detector catalog 2008/2009. The pdf-file can be found on http://www.ptw.de, PTW, Lörracher Strae 7, 79115 Freiburg, Germany
    • (2008) Ionizing Radiation Detector Catalog 2008/2009
  • 10
    • 0023622870 scopus 로고
    • General specifications for silicon semiconductors for use in radiation dosimetry
    • 10.1088/0031-9155/32/9/004
    • G Rikner E Grusell 1987 General specifications for silicon semiconductors for use in radiation dosimetry Phys Med Biol 32 9 1109 1117 10.1088/0031-9155/32/9/004
    • (1987) Phys Med Biol , vol.32 , Issue.9 , pp. 1109-1117
    • Rikner, G.1    Grusell, E.2
  • 11
    • 1942420364 scopus 로고    scopus 로고
    • Dose rate and SDD dependence of commercially available diode detectors
    • DOI 10.1118/1.1650563
    • AS Saini TC Zhu 2004 Dose rate and SSD dependence of commercially available diode detectors Med Phys 31 914 924 10.1118/1.1650563 (Pubitemid 38508873)
    • (2004) Medical Physics , vol.31 , Issue.4 , pp. 914-924
    • Saini, A.S.1    Zhu, T.C.2
  • 13
    • 0034065594 scopus 로고    scopus 로고
    • Comparative dosimetry in narrow high-energy photon beams
    • DOI 10.1088/0031-9155/45/3/308, PII S0031915500086930
    • M Westermark, et al. 2000 Comparative dosimetry in narrow high-energy photon beams Phys Med Biol 45 685 702 10.1088/0031-9155/45/3/308 (Pubitemid 30163657)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.3 , pp. 685-702
    • Westermark, M.1    Arndt, J.2    Nilsson, B.3    Brahme, A.4
  • 14
    • 0031760243 scopus 로고    scopus 로고
    • Characterization and use of a commericial n-type diode system
    • T Wolff, et al. 1998 Characterization and use of a commericial n-type diode system Br J Radiol 71 1168 1177
    • (1998) Br J Radiol , vol.71 , pp. 1168-1177
    • Wolff, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.