1
-
-
0034308356
-
The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
-
DOI 10.1016/S0021-9290(00)00094-4, PII S0021929000000944
-
DesJardins, J. D., Walker, P. S., Haider, H., and Perry, J., 2000, "The Use of a Force-Controlled Dynamic Knee Simulator to Quantify the Mechanical Performance of Total Knee Replacement Designs During Functional Activity," J. Biomech., 33, pp. 1231-1242. (Pubitemid 30427318)
-
(2000)
Journal of Biomechanics
, vol.33
, Issue.10
, pp. 1231-1242
-
-
Desjardins, J.D.1
Walker, P.S.2
Haider, H.3
Perry, J.4
-
2
-
-
0031059923
-
A Knee Simulating Machine for Performance Evaluation of Total Knee Replacements
-
Walker, P. S., Blunn, G. W., Broome, D. R., Perry, J., Watkin, S. A., Sathasivam, S., Dewar, M. E., and Paul, J. P., 1997, "A Knee Simulating Machine for Performance Evaluation of Total Knee Replacements," J. Biomech., 30, pp. 83-89.
-
(1997)
J. Biomech.
, vol.30
, pp. 83-89
-
-
Walker, P.S.1
Blunn, G.W.2
Broome, D.R.3
Perry, J.4
Watkin, S.A.5
Sathasivam, S.6
Dewar, M.E.7
Paul, J.P.8
-
3
-
-
0031106829
-
A Kinematic-Freedom Analysis of a Flexed-Knee-Stance Testing Rig
-
Zavatsky, A. B., 1997, "A Kinematic-Freedom Analysis of a Flexed-Knee-Stance Testing Rig," J. Biomech., 30, pp. 277-280.
-
(1997)
J. Biomech.
, vol.30
, pp. 277-280
-
-
Zavatsky, A.B.1
-
4
-
-
85069383920
-
Design of a Load Simulator for the Dynamic Evaluation of Prosthetic Knee Joints
-
Zachman, N. J., Hillberry, B. M., and Kettlekamp, D. B., 1978, "Design of a Load Simulator for the Dynamic Evaluation of Prosthetic Knee Joints," ASME Paper No. 78-DET-59, pp. 1-11.
-
(1978)
ASME Paper No. 78-DET-59
, pp. 1-11
-
-
Zachman, N.J.1
Hillberry, B.M.2
Kettlekamp, D.B.3
-
5
-
-
0028755373
-
Evaluation of a Dynamic Joint Simulator
-
Chao, E. Y. S., MacWilliams, B. A., Chan, B., and Meija, L., 1994, "Evaluation of a Dynamic Joint Simulator," ASME Bioeng. Div. Publ. Bed., Vol. 28, pp. 281-282.
-
(1994)
ASME Bioeng. Div. Publ. Bed.
, vol.28
, pp. 281-282
-
-
Chao, E.Y.S.1
MacWilliams, B.A.2
Chan, B.3
Meija, L.4
-
6
-
-
16244412257
-
Simulating Dynamic Activities Using a Five-Axis Knee Simulator
-
Maletsky, L. P., and Hillberry, B. M., 2005, "Simulating Dynamic Activities Using a Five-Axis Knee Simulator," ASME J. Biomech. Eng., 127, pp. 123-133.
-
(2005)
ASME J. Biomech. Eng.
, vol.127
, pp. 123-133
-
-
Maletsky, L.P.1
Hillberry, B.M.2
-
7
-
-
0031081160
-
A computer model with surface friction for the prediction of total knee kinematics
-
DOI 10.1016/S0021-9290(96)00114-5, PII S0021929096001145
-
Sathasivam, S., and Walker, P. S., 1997, "A Computer Model With Surface Friction for the Prediction of Total Knee Kinematics," J. Biomech., 30, pp. 177-184. (Pubitemid 27029796)
-
(1997)
Journal of Biomechanics
, vol.30
, Issue.2
, pp. 177-184
-
-
Sathasivam, S.1
Walker, P.S.2
-
8
-
-
0032170251
-
A Computer Model to Predict Subsurface Damage in Tibial Inserts of Total Knees
-
Sathasivam, S., and Walker, P. S., 1998, "A Computer Model to Predict Subsurface Damage in Tibial Inserts of Total Knees," J. Orthop. Res., 16, pp. 564-571.
-
(1998)
J. Orthop. Res.
, vol.16
, pp. 564-571
-
-
Sathasivam, S.1
Walker, P.S.2
-
9
-
-
0036136549
-
Flat Medial-Lateral Conformity in Total Knee Replacements Does Not Minimize Contact Stresses
-
Rawlinson, J. J., and Bartel, D. L., 2002, "Flat Medial-Lateral Conformity in Total Knee Replacements Does Not Minimize Contact Stresses," J. Biomech., 35, pp. 27-34.
-
(2002)
J. Biomech.
, vol.35
, pp. 27-34
-
-
Rawlinson, J.J.1
Bartel, D.L.2
-
10
-
-
0035472667
-
Total Knee Replacement Polyethylene Stresses during Loading in a Knee Simulator
-
Giddings, V. L., Kurtz, S. M., and Edidin, A. A., 2001, "Total Knee Replacement Polyethylene Stresses During Loading in a Knee Simulator," ASME J. Tribol., 123, pp. 842-847.
-
(2001)
ASME J. Tribol.
, vol.123
, pp. 842-847
-
-
Giddings, V.L.1
Kurtz, S.M.2
Edidin, A.A.3
-
11
-
-
0035666621
-
Three-Dimensional Dynamic Simulation of Total Knee Replacement Motion during a Step-Up Task
-
Piazza, S. J., and Delp, S. L., 2001, "Three-Dimensional Dynamic Simulation of Total Knee Replacement Motion During a Step-Up Task," ASME J. Biomech. Eng., 123, pp. 599-606.
-
(2001)
ASME J. Biomech. Eng.
, vol.123
, pp. 599-606
-
-
Piazza, S.J.1
Delp, S.L.2
-
12
-
-
0036137726
-
Simulation of a Knee Joint Replacement during Gait Cycle Using Explicit Finite Element Analysis
-
Godest, A. C., Beaugonin, M., Haug, E., Taylor, M., and Gregson, P. J., 2002, "Simulation of a Knee Joint Replacement During Gait Cycle Using Explicit Finite Element Analysis," J. Biomech., 35, pp. 267-275.
-
(2002)
J. Biomech.
, vol.35
, pp. 267-275
-
-
Godest, A.C.1
Beaugonin, M.2
Haug, E.3
Taylor, M.4
Gregson, P.J.5
-
13
-
-
10444255467
-
Explicit Finite Element Modeling of Total Knee Replacement Mechanics
-
Halloran, J. P., Petrella, A. J., and Rullkoetter, P. J., 2005a, "Explicit Finite Element Modeling of Total Knee Replacement Mechanics," J. Biomech., 38, pp. 323-331.
-
(2005)
J. Biomech.
, vol.38
, pp. 323-331
-
-
Halloran, J.P.1
Petrella, A.J.2
Rullkoetter, P.J.3
-
14
-
-
0034926225
-
The Effect of Component Placement on Knee Kinetics after Arthroplasty with an Unconstrained Prosthesis
-
Miller, M. C., Zhang, A. X., Petrella, A. J., Berger, R. A., and Rubash, H. E., 2001, "The Effect of Component Placement on Knee Kinetics After Arthroplasty With an Unconstrained Prosthesis," J. Orthop. Res., 19, pp. 614-620.
-
(2001)
J. Orthop. Res.
, vol.19
, pp. 614-620
-
-
Miller, M.C.1
Zhang, A.X.2
Petrella, A.J.3
Berger, R.A.4
Rubash, H.E.5
-
15
-
-
0025054164
-
The effect of femoral component position on patellar tracking after total knee arthroplasty
-
Rhoads, D. D., Noble, P. C., Reuben, J. D., Mahoney, O., and Tullow, H. S., 1990, "The Effect of Femoral Component Position on Patellar Tracking After Total Knee Arthroplasty," Clin. Orthop. Relat. Res., 260, pp. 43-51. (Pubitemid 20381515)
-
(1990)
Clinical Orthopaedics and Related Research
, Issue.260
, pp. 43-51
-
-
Rhoads, D.D.1
Noble, P.C.2
Reuben, J.D.3
Mahoney, O.M.4
Tullos, H.S.5
-
16
-
-
0028903342
-
Reduction of Patellofemoral Contact Forces Following Anterior Displacement of the Tibial Tubercle
-
Singerman, R., White, C., and Davy, D. T., 1995, "Reduction of Patellofemoral Contact Forces Following Anterior Displacement of the Tibial Tubercle," J. Orthop. Res., 13, pp. 279-285.
-
(1995)
J. Orthop. Res.
, vol.13
, pp. 279-285
-
-
Singerman, R.1
White, C.2
Davy, D.T.3
-
17
-
-
0031030203
-
Effect of Femoral Component Rotation and Patellar Design on Patellar Forces
-
Singerman, R., Pagan, H. D., Peyser, A. B., and Goldberg, V. M., 1997, "Effect of Femoral Component Rotation and Patellar Design on Patellar Forces," Clin. Orthop. Relat. Res., 334, pp. 345-353.
-
(1997)
Clin. Orthop. Relat. Res.
, vol.334
, pp. 345-353
-
-
Singerman, R.1
Pagan, H.D.2
Peyser, A.B.3
Goldberg, V.M.4
-
18
-
-
0026500860
-
The Effect of Patellar Button Placement and Femoral Component Design on Patellar Tracking in Total Knee Arthroplasty
-
Yoshii, I., Whiteside, L. A., and Anouchi, Y. S., 1992, "The Effect of Patellar Button Placement and Femoral Component Design on Patellar Tracking in Total Knee Arthroplasty," Clin. Orthop. Relat. Res., 275, pp. 211-219.
-
(1992)
Clin. Orthop. Relat. Res.
, vol.275
, pp. 211-219
-
-
Yoshii, I.1
Whiteside, L.A.2
Anouchi, Y.S.3
-
19
-
-
0027462377
-
The Effects of Axial Rotational Alignment of the Femoral Component on Knee Stability and Patellar Tracking in Total Knee Arthroplasty Demonstrated on Autopsy Specimens
-
Anouchi, Y. S., Whiteside, L. A., Kaiser, A. D., and Milliano, M. T., 1993, "The Effects of Axial Rotational Alignment of the Femoral Component on Knee Stability and Patellar Tracking in Total Knee Arthroplasty Demonstrated on Autopsy Specimens," Clin. Orthop. Relat. Res., 287, pp. 170-177.
-
(1993)
Clin. Orthop. Relat. Res.
, vol.287
, pp. 170-177
-
-
Anouchi, Y.S.1
Whiteside, L.A.2
Kaiser, A.D.3
Milliano, M.T.4
-
20
-
-
30344466397
-
Computational Modeling of a Dynamic Knee Simulator for Reproduction of Knee Loading
-
Guess, T. M., and Maletsky, L. P., 2005, "Computational Modeling of a Dynamic Knee Simulator for Reproduction of Knee Loading," ASME J. Biomech. Eng., 127, pp. 1216-1221.
-
(2005)
ASME J. Biomech. Eng.
, vol.127
, pp. 1216-1221
-
-
Guess, T.M.1
Maletsky, L.P.2
-
21
-
-
0020759032
-
A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the Knee
-
Grood, E. S., and Suntay, W. J., 1983, "A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the Knee," ASME J. Biomech. Eng., 105, pp. 136-144.
-
(1983)
ASME J. Biomech. Eng.
, vol.105
, pp. 136-144
-
-
Grood, E.S.1
Suntay, W.J.2
-
22
-
-
25444453812
-
Comparison of Deformable and Elastic Foundation Finite Element Simulations for Predicting Knee Replacement Mechanics
-
Halloran, J. P., Easley, S. K., Petrella, A. J., and Rullkoetter, P. J., 2005b, "Comparison of Deformable and Elastic Foundation Finite Element Simulations for Predicting Knee Replacement Mechanics," ASME J. Biomech. Eng., 127, pp. 813-818.
-
(2005)
ASME J. Biomech. Eng.
, vol.127
, pp. 813-818
-
-
Halloran, J.P.1
Easley, S.K.2
Petrella, A.J.3
Rullkoetter, P.J.4
-
23
-
-
25444506959
-
The Effect of Thickness and Nonlinear Material Behavior on Contact Stresses in Polyethylene Tibial Components
-
DeHeer, D. C., and Hillberry, B. M., 1992, "The Effect of Thickness and Nonlinear Material Behavior on Contact Stresses in Polyethylene Tibial Components," Trans. Annu. Meet. - Orthop. Res. Soc., 17, p. 793.
-
(1992)
Trans. Annu. Meet. - Orthop. Res. Soc.
, vol.17
, pp. 793
-
-
DeHeer, D.C.1
Hillberry, B.M.2
-
24
-
-
0004101501
-
-
Ph.D. thesis, Penn State University, University Park, PA
-
Lafortune, M. A., 1984, "The Use of Intra-Cortical Pins to Measure the Motion of the Knee Joint During Walking," Ph.D. thesis, Penn State University, University Park, PA.
-
(1984)
The Use of Intra-Cortical Pins to Measure the Motion of the Knee Joint during Walking
-
-
Lafortune, M.A.1
-
25
-
-
33846309629
-
Accuracy of an Optical Active-Marker System to Track the Relative Motion of Rigid Bodies
-
Maletsky, L. P., Sun, J., and Morton, N. A., 2007, "Accuracy of an Optical Active-Marker System to Track the Relative Motion of Rigid Bodies," J. Biomech., 40, pp. 682-685.
-
(2007)
J. Biomech.
, vol.40
, pp. 682-685
-
-
Maletsky, L.P.1
Sun, J.2
Morton, N.A.3
-
26
-
-
34548382706
-
Effect of Variability in Anatomical Landmark Location on Knee Kinematic Description
-
Morton, M. A., Maletsky, L. P., Pal, S., and Laz, P. J., 2007, "Effect of Variability in Anatomical Landmark Location on Knee Kinematic Description," J. Orthop. Res., 25, pp. 1221-1230.
-
(2007)
J. Orthop. Res.
, vol.25
, pp. 1221-1230
-
-
Morton, M.A.1
Maletsky, L.P.2
Pal, S.3
Laz, P.J.4
|