메뉴 건너뛰기




Volumn 38, Issue 4, 2010, Pages 430-436

Thromboplastin standards

Author keywords

International Normalized Ratio; Prothrombin Time; Standard; Thromboplastin; Vitamin K antagonist

Indexed keywords

ANTIVITAMIN K; THROMBOPLASTIN;

EID: 77955268964     PISSN: 10451056     EISSN: 10958320     Source Type: Journal    
DOI: 10.1016/j.biologicals.2010.02.012     Document Type: Review
Times cited : (16)

References (54)
  • 1
    • 0023911729 scopus 로고
    • Confusion over the therapeutic range for monitoring oral anticoagulant therapy in North America
    • Hirsh J., Levine M. Confusion over the therapeutic range for monitoring oral anticoagulant therapy in North America. Thromb Haemost 1988, 59:129-132.
    • (1988) Thromb Haemost , vol.59 , pp. 129-132
    • Hirsh, J.1    Levine, M.2
  • 2
    • 0000333461 scopus 로고
    • A study of the coagulation defect in hemophilia and in jaundice
    • Quick A.J., Stanley-Brown M., Bancroft F.W. A study of the coagulation defect in hemophilia and in jaundice. Am J Med Sci 1935, 190:501-511.
    • (1935) Am J Med Sci , vol.190 , pp. 501-511
    • Quick, A.J.1    Stanley-Brown, M.2    Bancroft, F.W.3
  • 4
    • 49749212311 scopus 로고
    • Thrombotest. A new method for controlling anticoagulant therapy
    • Owren P.A. Thrombotest. A new method for controlling anticoagulant therapy. Lancet 1959, 2:754-758.
    • (1959) Lancet , vol.2 , pp. 754-758
    • Owren, P.A.1
  • 5
    • 0022366401 scopus 로고
    • Laboratory control, optimal therapeutic ranges and therapeutic quality control in oral anticoagulation
    • Loeliger E.A. Laboratory control, optimal therapeutic ranges and therapeutic quality control in oral anticoagulation. Acta Haematol 1985, 74:125-131.
    • (1985) Acta Haematol , vol.74 , pp. 125-131
    • Loeliger, E.A.1
  • 6
    • 0014202159 scopus 로고
    • Standardization of the one-stage prothrombin time for the control of anticoagulant therapy
    • Biggs R., Denson K.W.E. Standardization of the one-stage prothrombin time for the control of anticoagulant therapy. Br Med J 1967, 1:84-88.
    • (1967) Br Med J , vol.1 , pp. 84-88
    • Biggs, R.1    Denson, K.W.E.2
  • 7
    • 0000018083 scopus 로고
    • ICSH/ICTH Recommendations for reporting prothrombin time in oral anticoagulant control
    • Loeliger E.A. ICSH/ICTH Recommendations for reporting prothrombin time in oral anticoagulant control. Thromb Haemost 1985, 54:155-156.
    • (1985) Thromb Haemost , vol.54 , pp. 155-156
    • Loeliger, E.A.1
  • 8
    • 77955238895 scopus 로고    scopus 로고
    • WHO Expert Committee on Biological Standardization, World Health Organization, Geneva
    • WHO Expert Committee on Biological Standardization Forty-eighth report. WHO Technical Report series, No. 889 1999, World Health Organization, Geneva, pp. 64-93.
    • (1999) Forty-eighth report. WHO Technical Report series, No. 889 , pp. 64-93
  • 9
    • 13244300475 scopus 로고
    • WHO Expert Committee on Biological Standardization, World Health Organization, Geneva
    • WHO Expert Committee on Biological Standardization Twenty-eighth report. WHO Technical Report series, No. 610 1977, World Health Organization, Geneva, p. 14.
    • (1977) Twenty-eighth report. WHO Technical Report series, No. 610 , pp. 14
  • 10
    • 0020512566 scopus 로고
    • Calibration of reference thromboplastins and standardisation of the prothrombin time ratio
    • Kirkwood T.B.L. Calibration of reference thromboplastins and standardisation of the prothrombin time ratio. Thromb Haemost 1983, 49:238-244.
    • (1983) Thromb Haemost , vol.49 , pp. 238-244
    • Kirkwood, T.B.L.1
  • 11
    • 0003635655 scopus 로고
    • WHO Expert Committee on Biological Standardization, World Health Organization, Geneva
    • WHO Expert Committee on Biological Standardization Thirty-third report. WHO Technical Report series, No. 687 1983, World Health Organization, Geneva, pp. 81-105.
    • (1983) Thirty-third report. WHO Technical Report series, No. 687 , pp. 81-105
  • 12
    • 0001822493 scopus 로고
    • A statistician's independent evaluation
    • Martinus Nijhoff Publishers, Boston, A.M.H.P. Van den Besselaar, H.R. Gralnick, S.M. Lewis (Eds.)
    • Tomenson J.A. A statistician's independent evaluation. Thromboplastin calibration and oral anticoagulant control 1984, 87-108. Martinus Nijhoff Publishers, Boston. A.M.H.P. Van den Besselaar, H.R. Gralnick, S.M. Lewis (Eds.).
    • (1984) Thromboplastin calibration and oral anticoagulant control , pp. 87-108
    • Tomenson, J.A.1
  • 13
    • 0027448113 scopus 로고
    • Multi-center study of thromboplastin calibration precision. Influence of reagent species, composition, and International Sensitivity Index (ISI)
    • Van den Besselaar A.M.H.P., Bertina R.M. Multi-center study of thromboplastin calibration precision. Influence of reagent species, composition, and International Sensitivity Index (ISI). Thromb Haemost 1993, 69:35-40.
    • (1993) Thromb Haemost , vol.69 , pp. 35-40
    • Van den Besselaar, A.M.H.P.1    Bertina, R.M.2
  • 14
    • 1842298906 scopus 로고
    • Draft report of a collaborative study of two thromboplastins (including the use of common abnormal plasma)
    • Bangham D.R., Biggs R., Brozović M., Denson K.W.E. Draft report of a collaborative study of two thromboplastins (including the use of common abnormal plasma). Thromb Diath Haemorrh 1970, (Suppl. 40):341-351.
    • (1970) Thromb Diath Haemorrh , Issue.SUPPL. 40 , pp. 341-351
    • Bangham, D.R.1    Biggs, R.2    Brozović, M.3    Denson, K.W.E.4
  • 16
    • 0021736809 scopus 로고
    • The calibration of the second primary International Reference Preparation for thromboplastin (thromboplastin, human, plain, coded BCT/253)
    • Thomson J.M., Tomenson J.A., Poller L. The calibration of the second primary International Reference Preparation for thromboplastin (thromboplastin, human, plain, coded BCT/253). Thromb Haemost 1984, 52:336-342.
    • (1984) Thromb Haemost , vol.52 , pp. 336-342
    • Thomson, J.M.1    Tomenson, J.A.2    Poller, L.3
  • 17
    • 0027501026 scopus 로고
    • Multi-center study of replacement of the International Reference Preparation for thromboplastin, rabbit, plain
    • Van den Besselaar A.M.H.P. Multi-center study of replacement of the International Reference Preparation for thromboplastin, rabbit, plain. Thromb Haemost 1993, 70:794-799.
    • (1993) Thromb Haemost , vol.70 , pp. 794-799
    • Van den Besselaar, A.M.H.P.1
  • 18
    • 0031936408 scopus 로고    scopus 로고
    • International collaborative study for the calibration of a proposed Reference Preparation for thromboplastin, human recombinant, plain
    • Tripodi A., Chantarangkul V., Negri B., Clerici M., Mannucci P.M. International collaborative study for the calibration of a proposed Reference Preparation for thromboplastin, human recombinant, plain. Thromb Haemost 1998, 79:439-443.
    • (1998) Thromb Haemost , vol.79 , pp. 439-443
    • Tripodi, A.1    Chantarangkul, V.2    Negri, B.3    Clerici, M.4    Mannucci, P.M.5
  • 19
    • 33646797021 scopus 로고    scopus 로고
    • International collaborative study for the calibration of a proposed International Standard for thromboplastin, rabbit, plain
    • Chantarangkul V., van den Besselaar A.M.H.P., Witteveen E., Tripodi A. International collaborative study for the calibration of a proposed International Standard for thromboplastin, rabbit, plain. J Thromb Haemost 2006, 4:1339-1345.
    • (2006) J Thromb Haemost , vol.4 , pp. 1339-1345
    • Chantarangkul, V.1    van den Besselaar, A.M.H.P.2    Witteveen, E.3    Tripodi, A.4
  • 20
    • 28444491055 scopus 로고    scopus 로고
    • Is there a need for replacement of the International Reference Preparation for thromboplastin, bovine, combined (OBT/79)?
    • Van den Besselaar A.M.H.P., Tripodi A. Is there a need for replacement of the International Reference Preparation for thromboplastin, bovine, combined (OBT/79)?. J Thromb Haemost 2005, 3:2365-2366.
    • (2005) J Thromb Haemost , vol.3 , pp. 2365-2366
    • Van den Besselaar, A.M.H.P.1    Tripodi, A.2
  • 21
    • 0032919783 scopus 로고    scopus 로고
    • Influence of three types of automated coagulometers on the International Sensitivity Index (ISI) of rabbit, human, and recombinant human tissue factor preparations
    • Van den Besselaar A.M.H.P., Houbouyan L.L., Aillaud M.F., Denson K.W.E., Johnston M., Kitchen S., et al. Influence of three types of automated coagulometers on the International Sensitivity Index (ISI) of rabbit, human, and recombinant human tissue factor preparations. Thromb Haemost 1999, 81:66-70.
    • (1999) Thromb Haemost , vol.81 , pp. 66-70
    • Van den Besselaar, A.M.H.P.1    Houbouyan, L.L.2    Aillaud, M.F.3    Denson, K.W.E.4    Johnston, M.5    Kitchen, S.6
  • 22
    • 0031851147 scopus 로고    scopus 로고
    • Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations
    • Chantarangkul V., Tripodi A., Clerici M., Negri B., Mannucci P.M. Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations. Thromb Haemost 1998, 80:258-262.
    • (1998) Thromb Haemost , vol.80 , pp. 258-262
    • Chantarangkul, V.1    Tripodi, A.2    Clerici, M.3    Negri, B.4    Mannucci, P.M.5
  • 23
    • 14544287715 scopus 로고    scopus 로고
    • Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/International Normalized Ratio test and implications for monitoring of oral anticoagulant therapy
    • Van Geest-Daalderop J.H.H., Mulder A.B., Boonman-de Winter L.J.M., Hoekstra M.M.C.L., van den Besselaar A.M.H.P. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/International Normalized Ratio test and implications for monitoring of oral anticoagulant therapy. Clin Chem 2005, 51:561-568.
    • (2005) Clin Chem , vol.51 , pp. 561-568
    • Van Geest-Daalderop, J.H.H.1    Mulder, A.B.2    Boonman-de Winter, L.J.M.3    Hoekstra, M.M.C.L.4    van den Besselaar, A.M.H.P.5
  • 24
    • 0036825378 scopus 로고    scopus 로고
    • How to evaluate the influence of blood collection systems on the International Sensitivity Index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations
    • Tripodi A., Chantarangkul V., Bressi C., Mannucci P.M. How to evaluate the influence of blood collection systems on the International Sensitivity Index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations. Thromb Res 2003, 108:85-89.
    • (2003) Thromb Res , vol.108 , pp. 85-89
    • Tripodi, A.1    Chantarangkul, V.2    Bressi, C.3    Mannucci, P.M.4
  • 25
    • 11144284730 scopus 로고    scopus 로고
    • Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer
    • Van den Besselaar A.M.H.P., Rutten W.P.F., Witteveen E. Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer. Thromb Res 2005, 115:239-244.
    • (2005) Thromb Res , vol.115 , pp. 239-244
    • Van den Besselaar, A.M.H.P.1    Rutten, W.P.F.2    Witteveen, E.3
  • 26
    • 34249749969 scopus 로고    scopus 로고
    • Influence of blood collection systems on the prothrombin time and International Sensitivity Index determined with human and rabbit thromboplastin reagents
    • Van den Besselaar A.M.H.P., Hoekstra M.M.C.L., Witteveen E., Didden J.H., van der Meer F.J.M. Influence of blood collection systems on the prothrombin time and International Sensitivity Index determined with human and rabbit thromboplastin reagents. Am J Clin Pathol 2007, 127:724-729.
    • (2007) Am J Clin Pathol , vol.127 , pp. 724-729
    • Van den Besselaar, A.M.H.P.1    Hoekstra, M.M.C.L.2    Witteveen, E.3    Didden, J.H.4    van der Meer, F.J.M.5
  • 27
    • 33750918843 scopus 로고    scopus 로고
    • Calibration guidelines challenge outlier practices
    • Finney D.J. Calibration guidelines challenge outlier practices. Am Stat 2006, 60:309-314.
    • (2006) Am Stat , vol.60 , pp. 309-314
    • Finney, D.J.1
  • 28
    • 37849017671 scopus 로고    scopus 로고
    • Interaction of daptomycin with two recombinant thromboplastin reagents leads to falsely prolonged patient prothrombin time/International Normalized Ratio results
    • Webster P.S., Oleson F.B., Paterson D.L., Arkin C.F., Mangili A., Craven D.E., et al. Interaction of daptomycin with two recombinant thromboplastin reagents leads to falsely prolonged patient prothrombin time/International Normalized Ratio results. Blood Coagul Fibrinolysis 2008, 19:32-38.
    • (2008) Blood Coagul Fibrinolysis , vol.19 , pp. 32-38
    • Webster, P.S.1    Oleson, F.B.2    Paterson, D.L.3    Arkin, C.F.4    Mangili, A.5    Craven, D.E.6
  • 29
    • 34548106988 scopus 로고    scopus 로고
    • Effect of daptomycin on prothrombin time and the requirement for outlier exclusion in International Sensitivity Index calibration of thromboplastin
    • Van den Besselaar A.M.H.P., Tripodi A. Effect of daptomycin on prothrombin time and the requirement for outlier exclusion in International Sensitivity Index calibration of thromboplastin. J Thromb Haemost 2007, 5:1975-1976.
    • (2007) J Thromb Haemost , vol.5 , pp. 1975-1976
    • Van den Besselaar, A.M.H.P.1    Tripodi, A.2
  • 30
    • 0038309361 scopus 로고    scopus 로고
    • Inaccuracy of International Normalized Ratio (INR) measurements and suggestions for improved WHO guidelines for calibration of reference preparations - a statistical study
    • Attermann J. Inaccuracy of International Normalized Ratio (INR) measurements and suggestions for improved WHO guidelines for calibration of reference preparations - a statistical study. J Thromb Haemost 2003, 1:537-544.
    • (2003) J Thromb Haemost , vol.1 , pp. 537-544
    • Attermann, J.1
  • 31
    • 0028784813 scopus 로고
    • Calibration of thromboplastins
    • Finney D.J. Calibration of thromboplastins. Proc R Soc Lond B 1995, 262:71-75.
    • (1995) Proc R Soc Lond B , vol.262 , pp. 71-75
    • Finney, D.J.1
  • 32
  • 34
    • 33747147412 scopus 로고    scopus 로고
    • Long-term stability of relationships between reference materials for thromboplastins
    • Linsinger T.P.J., van den Besselaar A.M.H.P., Tripodi A. Long-term stability of relationships between reference materials for thromboplastins. Thromb Haemost 2006, 96:210-214.
    • (2006) Thromb Haemost , vol.96 , pp. 210-214
    • Linsinger, T.P.J.1    van den Besselaar, A.M.H.P.2    Tripodi, A.3
  • 35
    • 0036714322 scopus 로고    scopus 로고
    • A reassessment of the relationship between International Reference Preparations for human and rabbit thromboplastins
    • Van den Besselaar A.M.H.P., Tripodi A. A reassessment of the relationship between International Reference Preparations for human and rabbit thromboplastins. Thromb Haemost 2002, 88:459-461.
    • (2002) Thromb Haemost , vol.88 , pp. 459-461
    • Van den Besselaar, A.M.H.P.1    Tripodi, A.2
  • 36
    • 20444474648 scopus 로고    scopus 로고
    • European concerted action on anticoagulation. A multicentre calibration study of WHO International Reference Preparations for thromboplastin, rabbit (RBT/90) and human (rTF/95)
    • Poller L., Keown M., Chauhan N., van den Besselaar A.M.H.P., Tripodi A., Shiach C., et al. European concerted action on anticoagulation. A multicentre calibration study of WHO International Reference Preparations for thromboplastin, rabbit (RBT/90) and human (rTF/95). J Clin Pathol 2005, 58:667-669.
    • (2005) J Clin Pathol , vol.58 , pp. 667-669
    • Poller, L.1    Keown, M.2    Chauhan, N.3    van den Besselaar, A.M.H.P.4    Tripodi, A.5    Shiach, C.6
  • 39
    • 0033061383 scopus 로고    scopus 로고
    • An international collaborative study on the INR calibration of freeze-dried reference plasmas
    • Hubbard A.R., Margetts S.M.L., Weller L.J., Macnab J., Barrowcliffe T.W. An international collaborative study on the INR calibration of freeze-dried reference plasmas. Br J Haematol 1999, 104:455-460.
    • (1999) Br J Haematol , vol.104 , pp. 455-460
    • Hubbard, A.R.1    Margetts, S.M.L.2    Weller, L.J.3    Macnab, J.4    Barrowcliffe, T.W.5
  • 41
    • 15744399322 scopus 로고    scopus 로고
    • Usefulness of lyophilized calibration plasmas for International Normalized Ratio determination with the bovine combined thromboplastin (Thrombotest): results of a collaborative study
    • Chantarangkul V., Frontini R., Gresele P., Oca G., Paniccia R., Pellegrini L., et al. Usefulness of lyophilized calibration plasmas for International Normalized Ratio determination with the bovine combined thromboplastin (Thrombotest): results of a collaborative study. Blood Coagul Fibrinolysis 2005, 16:157-163.
    • (2005) Blood Coagul Fibrinolysis , vol.16 , pp. 157-163
    • Chantarangkul, V.1    Frontini, R.2    Gresele, P.3    Oca, G.4    Paniccia, R.5    Pellegrini, L.6
  • 42
    • 0344083658 scopus 로고    scopus 로고
    • Use of lyophilized calibrant plasmas for simplified International Normalized Ratio determination with a human tissue factor thromboplastin reagent derived from cultured human cells
    • Van den Besselaar A.M.H.P., Houdijk W.P.M. Use of lyophilized calibrant plasmas for simplified International Normalized Ratio determination with a human tissue factor thromboplastin reagent derived from cultured human cells. Clin Chem 2003, 49:2006-2011.
    • (2003) Clin Chem , vol.49 , pp. 2006-2011
    • Van den Besselaar, A.M.H.P.1    Houdijk, W.P.M.2
  • 43
    • 42449129124 scopus 로고    scopus 로고
    • Time to think outside the box? Prothrombin time, International Normalised Ratio, International Sensitivity Index, mean normal prothrombin time and measurement of uncertainty: a novel approach to standardisation
    • Favaloro E.J., Hamdam S., McDonald J., McVicker W., Ule V. Time to think outside the box? Prothrombin time, International Normalised Ratio, International Sensitivity Index, mean normal prothrombin time and measurement of uncertainty: a novel approach to standardisation. Pathology 2008, 40:277-287.
    • (2008) Pathology , vol.40 , pp. 277-287
    • Favaloro, E.J.1    Hamdam, S.2    McDonald, J.3    McVicker, W.4    Ule, V.5
  • 44
    • 0028791287 scopus 로고
    • Comparing methods of measurement: why plotting difference against standard method is misleading
    • Bland J.M., Altman D.G. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995, 346:1085-1087.
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 45
    • 0037223652 scopus 로고    scopus 로고
    • United Network for organ Sharing liver disease Severity score Committee. Model for end-stage liver disease (MELD) and allocation of donor liver
    • Wiesner R., Edwards E., Freeman R., Harper A., Kim R., Kamath P., et al. United Network for organ Sharing liver disease Severity score Committee. Model for end-stage liver disease (MELD) and allocation of donor liver. Gastroenterology 2003, 124:91-96.
    • (2003) Gastroenterology , vol.124 , pp. 91-96
    • Wiesner, R.1    Edwards, E.2    Freeman, R.3    Harper, A.4    Kim, R.5    Kamath, P.6
  • 46
    • 4544300925 scopus 로고    scopus 로고
    • Specific laboratory methodologies achieve higher model for endstage liver disease (MELD) scores for patients listed for liver transplantation
    • Trotter J.F., Brimhall B., Arjal R., Phillips C. Specific laboratory methodologies achieve higher model for endstage liver disease (MELD) scores for patients listed for liver transplantation. Liver Transpl 2004, 10:995-1000.
    • (2004) Liver Transpl , vol.10 , pp. 995-1000
    • Trotter, J.F.1    Brimhall, B.2    Arjal, R.3    Phillips, C.4
  • 47
    • 0029912013 scopus 로고    scopus 로고
    • Prothrombin time in liver failure: time, ratio, activity percentage, or International Normalized Ratio?
    • Robert A., Chazouilleres O. Prothrombin time in liver failure: time, ratio, activity percentage, or International Normalized Ratio?. Hepatology 1996, 24:1392-1394.
    • (1996) Hepatology , vol.24 , pp. 1392-1394
    • Robert, A.1    Chazouilleres, O.2
  • 48
    • 0028365539 scopus 로고
    • Assessment of the validity of the INR system for patients with liver impairment
    • Kovacs M.J., Wong A., MacKinnon K., Weir K., Keeney M., Boyle E., et al. Assessment of the validity of the INR system for patients with liver impairment. Thromb Haemost 1994, 71:727-730.
    • (1994) Thromb Haemost , vol.71 , pp. 727-730
    • Kovacs, M.J.1    Wong, A.2    MacKinnon, K.3    Weir, K.4    Keeney, M.5    Boyle, E.6
  • 51
    • 34548297386 scopus 로고    scopus 로고
    • A modified International Normalized Ratio as an effective way of prothrombin time standardization in hepatology
    • Bellest L., Eschwege V., Poupon R., Chazouillères O., Robert A. A modified International Normalized Ratio as an effective way of prothrombin time standardization in hepatology. Hepatology 2007, 46:528-534.
    • (2007) Hepatology , vol.46 , pp. 528-534
    • Bellest, L.1    Eschwege, V.2    Poupon, R.3    Chazouillères, O.4    Robert, A.5
  • 53
    • 38349193435 scopus 로고    scopus 로고
    • The International Normalized Ratio to prioritize patients for liver transplantation. Problems and possible solutions
    • Tripodi A., Chantarangkul V., Mannucci P.M. The International Normalized Ratio to prioritize patients for liver transplantation. Problems and possible solutions. J Thromb Haemost 2008, 6:243-248.
    • (2008) J Thromb Haemost , vol.6 , pp. 243-248
    • Tripodi, A.1    Chantarangkul, V.2    Mannucci, P.M.3
  • 54
    • 42249099002 scopus 로고    scopus 로고
    • liver) for model of end-stage liver disease calculation
    • liver) for model of end-stage liver disease calculation. Hepatology 2008, 47:1423-1424.
    • (2008) Hepatology , vol.47 , pp. 1423-1424
    • Tripodi, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.