메뉴 건너뛰기




Volumn 19, Issue 6, 2010, Pages 465-470

Effect of veneering techniques on color and translucency of y-tzp

Author keywords

All ceramic; Color; Zirconia

Indexed keywords

APATITE; FLUORAPATITE; GLASS CERAMICS; IPS E.MAX CAD LT; IPS E.MAX PRESS; YTTRIA STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTALS CERAMIC; YTTRIA-STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTALS CERAMIC; YTTRIUM; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 77955252616     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2010.00610.x     Document Type: Article
Times cited : (51)

References (45)
  • 1
    • 0000653434 scopus 로고
    • The reinforcement of dental porcelain with ceramic oxides
    • McLean JW, Hughes TH. The reinforcement of dental porcelain with ceramic oxides. Br Dent J 1965, 119:251-267.
    • (1965) Br Dent J , vol.119 , pp. 251-267
    • McLean, J.W.1    Hughes, T.H.2
  • 2
    • 0029678682 scopus 로고    scopus 로고
    • Ceramics in dentistry: historical roots and current perspectives
    • Kelly JR, Nishimura I, Campbell SD. Ceramics in dentistry: historical roots and current perspectives. J Prosthet Dent 1996, 75:18-32.
    • (1996) J Prosthet Dent , vol.75 , pp. 18-32
    • Kelly, J.R.1    Nishimura, I.2    Campbell, S.D.3
  • 3
    • 33749677224 scopus 로고    scopus 로고
    • The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study
    • Raigrodski AJ, Chiche GJ, Potiket N. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 2006, 96:237-244.
    • (2006) J Prosthet Dent , vol.96 , pp. 237-244
    • Raigrodski, A.J.1    Chiche, G.J.2    Potiket, N.3    et al4
  • 4
    • 0004248248 scopus 로고
    • Introduction to Ceramics (ed 2)
    • New York, Wiley
    • Kingery W, Bowen H, Uhlmann D. Introduction to Ceramics (ed 2). 1976, 89. New York, Wiley, pp
    • (1976) , pp. 89
    • Kingery, W.1    Bowen, H.2    Uhlmann, D.3
  • 6
    • 0036635935 scopus 로고    scopus 로고
    • Relative translucency of six all-ceramic systems. Part II: core and veneer materials
    • Heffernan MJ, Aquilino SA, Diaz-Arnold AM. Relative translucency of six all-ceramic systems. Part II: core and veneer materials. J Prosthet Dent 2002, 88:10-15.
    • (2002) J Prosthet Dent , vol.88 , pp. 10-15
    • Heffernan, M.J.1    Aquilino, S.A.2    Diaz-Arnold, A.M.3    et al4
  • 7
    • 0023489948 scopus 로고
    • Organizing color in dentistry
    • Special No:26E-40E
    • Miller L. Organizing color in dentistry. J Am Dent Assoc 1987, Special No:26E-40E
    • (1987) J Am Dent Assoc
    • Miller, L.1
  • 9
    • 34250889147 scopus 로고    scopus 로고
    • Light transmission through all-ceramic framework and cement combinations
    • 81(Spec. issue) abstractμ1179
    • Edelhoff D, Sorensen J. Light transmission through all-ceramic framework and cement combinations. J Dent Res 2002, 81(Spec. issue) abstractμ1179
    • (2002) J Dent Res
    • Edelhoff, D.1    Sorensen, J.2
  • 10
    • 0004041711 scopus 로고    scopus 로고
    • Colorimetry: Official Recommendations of the International Commission on Illumination
    • CIE, Paris, International Commission on Illumination Publication CIE No. 15(E-1.3.1) 1976
    • Colorimetry: Official Recommendations of the International Commission on Illumination. CIE, Paris, International Commission on Illumination Publication CIE No. 15(E-1.3.1) 1976
  • 11
    • 0016950728 scopus 로고
    • Color-tolerance data and the tentative CIE 1976 Lab formula
    • Kuehni RG. Color-tolerance data and the tentative CIE 1976 Lab formula. J Opt Soc Am 1976, 66:497-500.
    • (1976) J Opt Soc Am , vol.66 , pp. 497-500
    • Kuehni, R.G.1
  • 12
    • 0026195011 scopus 로고
    • Factors affecting the process of color matching restorative materials to natural teeth
    • Knispel G. Factors affecting the process of color matching restorative materials to natural teeth. Quintessence Int 1991, 22:25-31.
    • (1991) Quintessence Int , vol.22 , pp. 25-31
    • Knispel, G.1
  • 14
    • 0034584193 scopus 로고    scopus 로고
    • A method for evaluating color stability of light-cured composite resins using an experimental filter
    • Arikawa H, Kanie T, Shinohara N. A method for evaluating color stability of light-cured composite resins using an experimental filter. Dent Mater J 2000, 19:338-345.
    • (2000) Dent Mater J , vol.19 , pp. 338-345
    • Arikawa, H.1    Kanie, T.2    Shinohara, N.3    et al4
  • 15
    • 0026231125 scopus 로고
    • Variables affecting the spectral transmittance of light through porcelain veneer samples
    • O'Keefe KL, Pease PL, Herrin HK. Variables affecting the spectral transmittance of light through porcelain veneer samples. J Prosthet Dent 1991, 66:434-438.
    • (1991) J Prosthet Dent , vol.66 , pp. 434-438
    • O'Keefe, K.L.1    Pease, P.L.2    Herrin, H.K.3
  • 16
    • 0006543057 scopus 로고
    • Optical Society of America Committee on Colorimetry, Binghamton, NY, Thomas Y. Crowell
    • The Science of Color 1953, Optical Society of America Committee on Colorimetry, Binghamton, NY, Thomas Y. Crowell
    • (1953) The Science of Color
  • 17
    • 0022061170 scopus 로고
    • Optical properties of esthetic restorative materials and natural dentition
    • Cook WD, McAree DC. Optical properties of esthetic restorative materials and natural dentition. J Biomed Mater Res 1985, 19:469-488.
    • (1985) J Biomed Mater Res , vol.19 , pp. 469-488
    • Cook, W.D.1    McAree, D.C.2
  • 18
    • 0029315464 scopus 로고
    • A note on the accuracy of inexpensive light meters for measuring luminous transmittance
    • Smith G, Jenkins SE. A note on the accuracy of inexpensive light meters for measuring luminous transmittance. Optom Vis Sci 1995, 72:426-427.
    • (1995) Optom Vis Sci , vol.72 , pp. 426-427
    • Smith, G.1    Jenkins, S.E.2
  • 19
    • 0346034981 scopus 로고
    • Tooth color selection
    • Clark EB. Tooth color selection. J Am Dent Assoc 1933, 20:1065-1073.
    • (1933) J Am Dent Assoc , vol.20 , pp. 1065-1073
    • Clark, E.B.1
  • 20
    • 9944229063 scopus 로고    scopus 로고
    • Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature
    • Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004, 97:557-562.
    • (2004) J Prosthet Dent , vol.97 , pp. 557-562
    • Raigrodski, A.J.1
  • 21
    • 0034204345 scopus 로고    scopus 로고
    • Porcelain esthetics for the 21st century
    • Leinfelder KF. Porcelain esthetics for the 21st century. J Am Dent Assoc 2000, 131:47-51.
    • (2000) J Am Dent Assoc , vol.131 , pp. 47-51
    • Leinfelder, K.F.1
  • 22
    • 0035220559 scopus 로고    scopus 로고
    • Evolution of dental ceramics in the twentieth century
    • Mclean JW. Evolution of dental ceramics in the twentieth century. J Prosthet Dent 2001, 85:61-66.
    • (2001) J Prosthet Dent , vol.85 , pp. 61-66
    • Mclean, J.W.1
  • 23
    • 0035407230 scopus 로고    scopus 로고
    • Contrast ratio of veneering and core ceramics as a function of thickness
    • Antonson SA, Anusavice KJ. Contrast ratio of veneering and core ceramics as a function of thickness. Int J Prosthodont 2001, 14:316-320.
    • (2001) Int J Prosthodont , vol.14 , pp. 316-320
    • Antonson, S.A.1    Anusavice, K.J.2
  • 25
    • 0029438254 scopus 로고
    • New dental ceramics and esthetics
    • Mclean JW. New dental ceramics and esthetics. J Esthet Dent 1995, 7:141-149.
    • (1995) J Esthet Dent , vol.7 , pp. 141-149
    • Mclean, J.W.1
  • 26
    • 0347480520 scopus 로고    scopus 로고
    • The influence of porcelain layer thickness on the final shade of ceramic restorations
    • Dozic A, Kleverlaan CJ, Meegdes M. The influence of porcelain layer thickness on the final shade of ceramic restorations. J Prosthet Dent 2003, 90:563-570.
    • (2003) J Prosthet Dent , vol.90 , pp. 563-570
    • Dozic, A.1    Kleverlaan, C.J.2    Meegdes, M.3    et al4
  • 28
    • 0026111517 scopus 로고
    • A quantitative study for the bond and color of ceramometals, part 2
    • Hammad IA, Stein RS. A quantitative study for the bond and color of ceramometals, part 2. J Prosthet Dent 1991, 65:169-178.
    • (1991) J Prosthet Dent , vol.65 , pp. 169-178
    • Hammad, I.A.1    Stein, R.S.2
  • 29
    • 0033172974 scopus 로고    scopus 로고
    • Predicting porcelain thickness required for dental shade matches
    • Douglas RD, Przybylska M. Predicting porcelain thickness required for dental shade matches. J Prosthet Dent 1999, 82:143-149.
    • (1999) J Prosthet Dent , vol.82 , pp. 143-149
    • Douglas, R.D.1    Przybylska, M.2
  • 30
    • 77955235773 scopus 로고    scopus 로고
    • Chromatic study of all-ceramic crown-IPS Empress: difference of color by manufacturing technique and cements
    • Hata U, Sadamitsu K, Yamamura O. Chromatic study of all-ceramic crown-IPS Empress: difference of color by manufacturing technique and cements. Nihon Hotetsu Shika Gakkai Zasshi 2004, 48:703-712.
    • (2004) Nihon Hotetsu Shika Gakkai Zasshi , vol.48 , pp. 703-712
    • Hata, U.1    Sadamitsu, K.2    Yamamura, O.3    et al4
  • 32
    • 0024672149 scopus 로고
    • Assessment of appearance match by visual observation and clinical colorimetry
    • Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 1989, 68:819-822.
    • (1989) J Dent Res , vol.68 , pp. 819-822
    • Johnston, W.M.1    Kao, E.C.2
  • 33
    • 0024845926 scopus 로고
    • Visual and instrumental colorimetric assessments of small color differences on translucent dental ceramic
    • Seghi RR, Hewlett ER, Kim J. Visual and instrumental colorimetric assessments of small color differences on translucent dental ceramic. J Dent Res 1989, 68:1760-1764.
    • (1989) J Dent Res , vol.68 , pp. 1760-1764
    • Seghi, R.R.1    Hewlett, E.R.2    Kim, J.3
  • 34
    • 0039847703 scopus 로고    scopus 로고
    • Color acceptance of direct dental restorative materials by human observers
    • Ragain JC, Johnston WM. Color acceptance of direct dental restorative materials by human observers. Color Res Appl 2000, 25:278-285.
    • (2000) Color Res Appl , vol.25 , pp. 278-285
    • Ragain, J.C.1    Johnston, W.M.2
  • 35
    • 0032016260 scopus 로고    scopus 로고
    • Acceptability of shade differences in metal ceramic crowns
    • Douglas RD, Brewer JD. Acceptability of shade differences in metal ceramic crowns. J Prosthet Dent 1998, 79:254-260.
    • (1998) J Prosthet Dent , vol.79 , pp. 254-260
    • Douglas, R.D.1    Brewer, J.D.2
  • 36
    • 34247868727 scopus 로고    scopus 로고
    • Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch
    • Douglas RD, Steinhauer TJ. Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch. J Prosthet Dent 2007, 97:200-208.
    • (2007) J Prosthet Dent , vol.97 , pp. 200-208
    • Douglas, R.D.1    Steinhauer, T.J.2
  • 37
    • 34249751607 scopus 로고    scopus 로고
    • Layered color of all-ceramic core and veneer ceramics
    • Lee YK, Cha HS, Ahn JS. Layered color of all-ceramic core and veneer ceramics. J Prosthet Dent 2007, 97:279-286.
    • (2007) J Prosthet Dent , vol.97 , pp. 279-286
    • Lee, Y.K.1    Cha, H.S.2    Ahn, J.S.3
  • 38
    • 0034305560 scopus 로고    scopus 로고
    • Double-layer poecelain veneers: effect of layering on resulting veneer color
    • Zhang F, Heydecke G, Razzoog ME. Double-layer poecelain veneers: effect of layering on resulting veneer color. J Prosthet Dent 2000, 84:425-431.
    • (2000) J Prosthet Dent , vol.84 , pp. 425-431
    • Zhang, F.1    Heydecke, G.2    Razzoog, M.E.3
  • 39
    • 32244444999 scopus 로고    scopus 로고
    • Effect of core and veneer thickness on the color parameters of two all-ceramic systems
    • Shokry TE, Shen C, Elhosary MM. Effect of core and veneer thickness on the color parameters of two all-ceramic systems. J Prosthet Dent 2006, 95:124-129.
    • (2006) J Prosthet Dent , vol.95 , pp. 124-129
    • Shokry, T.E.1    Shen, C.2    Elhosary, M.M.3    et al4
  • 40
    • 0025382325 scopus 로고
    • A comparison of new and conventional methods for quantification of tooth color
    • Van Der Burgt TP, ten Bosch JJ, Borsboom PC. A comparison of new and conventional methods for quantification of tooth color. J Prosthet Dent 1990, 63:155-162.
    • (1990) J Prosthet Dent , vol.63 , pp. 155-162
    • Van Der Burgt, T.P.1    ten Bosch, J.J.2    Borsboom, P.C.3    et al4
  • 41
    • 0019568868 scopus 로고
    • Instrumental color measurement of vital and extracted human teeth
    • MacEntee M, Lakowski R. Instrumental color measurement of vital and extracted human teeth. J Oral Rehabil 1981, 8:203-208.
    • (1981) J Oral Rehabil , vol.8 , pp. 203-208
    • MacEntee, M.1    Lakowski, R.2
  • 42
    • 0029180699 scopus 로고
    • Tooth color and reflectance as related to light scattering and enamel hardness
    • Ten Bosch JJ, Coops JC. Tooth color and reflectance as related to light scattering and enamel hardness. J Dent Res 1995, 74:374-380.
    • (1995) J Dent Res , vol.74 , pp. 374-380
    • Ten Bosch, J.J.1    Coops, J.C.2
  • 44
    • 0034166882 scopus 로고    scopus 로고
    • Influence of ceramic and cement thickness on the masking of various types of opaque posts
    • Vichi A, Ferrari M, Dabidson CL. Influence of ceramic and cement thickness on the masking of various types of opaque posts. J Prosthet Dent 2000, 83:412-417.
    • (2000) J Prosthet Dent , vol.83 , pp. 412-417
    • Vichi, A.1    Ferrari, M.2    Dabidson, C.L.3
  • 45
    • 3242812102 scopus 로고    scopus 로고
    • Spectrophotometric analysis of all-ceramic materials and their interaction with luting agents and different backgrounds
    • Barath VS, Faber FJ, Westland S. Spectrophotometric analysis of all-ceramic materials and their interaction with luting agents and different backgrounds. Adv Dent Res 2003, 17:55-60.
    • (2003) Adv Dent Res , vol.17 , pp. 55-60
    • Barath, V.S.1    Faber, F.J.2    Westland, S.3    et al4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.