메뉴 건너뛰기




Volumn 67, Issue 2, 2010, Pages 467-469

Usefulness of C-arm cone-beam computed tomography in endovascular treatment of traumatic carotid cavernous fistulas: A technical case report

Author keywords

Angiography; Carotid cavernous fistula; Cone beam CT; Endovascular; Trauma

Indexed keywords

IOPAMIDOL;

EID: 77954962762     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000372087.71176.FB     Document Type: Article
Times cited : (8)

References (15)
  • 1
    • 0016258762 scopus 로고
    • Balloon catheterization and occlusion of major cerebral vessels
    • Serbinenko FA. Balloon catheterization and occlusion of major cerebral vessels. J Neurosurg. 1974;41(2):125-145.
    • (1974) J Neurosurg , vol.41 , Issue.2 , pp. 125-145
    • Serbinenko, F.A.1
  • 2
    • 0032471330 scopus 로고    scopus 로고
    • Traumatic carotid cavernous sinus fistula: Serial angiographic studies from the day of trauma
    • Komiyama M, Nakajima H, Nishikawa M, Kan M. Traumatic carotid cavernous sinus fistula: serial angiographic studies from the day of trauma. AJNR Am J Neuroradiol. 1998;19(9):1641-1644.
    • (1998) AJNR Am J Neuroradiol , vol.19 , Issue.9 , pp. 1641-1644
    • Komiyama, M.1    Nakajima, H.2    Nishikawa, M.3    Kan, M.4
  • 3
    • 0141640809 scopus 로고    scopus 로고
    • Transvenous treatment of carotid cavernous and dural arteriovenous fistulae: Results for 31 patients and review of the literature
    • Klisch J, Huppertz HJ, Spetzger U, Hetzel A, Seeger W, Schumacher M. Transvenous treatment of carotid cavernous and dural arteriovenous fistulae: results for 31 patients and review of the literature. Neurosurgery. 2003;53(4):836-856.
    • (2003) Neurosurgery , vol.53 , Issue.4 , pp. 836-856
    • Klisch, J.1    Huppertz, H.J.2    Spetzger, U.3    Hetzel, A.4    Seeger, W.5    Schumacher, M.6
  • 4
    • 33847096749 scopus 로고    scopus 로고
    • Scialfa. Angiographic follow-up of traumatic carotid cavernous fistulas treated with endovascular stent graft placement
    • Archondakis E, Pero G, Valvassori L, Boccardi E, Scialfa. Angiographic follow-up of traumatic carotid cavernous fistulas treated with endovascular stent graft placement. AJNR Am J Neuroradiol. 2007;28:342-347.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 342-347
    • Archondakis, E.1    Pero, G.2    Valvassori, L.3    Boccardi, E.4
  • 5
    • 0030029913 scopus 로고    scopus 로고
    • Long-term results in direct carotidcavernous fistulas after treatment with detachable balloons
    • Lewis AI, Tomsick TA, Tew JM Jr, Lawless MA. Long-term results in direct carotidcavernous fistulas after treatment with detachable balloons. J Neurosurg. 1996; 84(3):400-404.
    • (1996) J Neurosurg , vol.84 , Issue.3 , pp. 400-404
    • Lewis, A.I.1    Tomsick, T.A.2    Tew Jr., J.M.3    Lawless, M.A.4
  • 6
    • 44149113722 scopus 로고    scopus 로고
    • C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology
    • Orth RC, Wallance MJ, Kuo MD. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol. 2008;19(6):814-821.
    • (2008) J Vasc Interv Radiol , vol.19 , Issue.6 , pp. 814-821
    • Orth, R.C.1    Wallance, M.J.2    Kuo, M.D.3
  • 7
    • 42449142411 scopus 로고    scopus 로고
    • DynaCT soft-tissue visualization using an angiographic C-arm system: Initial clinical experience in the operating room
    • Irie K, Murayama Y, Saguchi T, et al. DynaCT soft-tissue visualization using an angiographic C-arm system: initial clinical experience in the operating room. Neurosurgery. 2008;62(3)(suppl 1):266-272.
    • (2008) Neurosurgery , vol.62 , Issue.3 SUPPL. 1 , pp. 266-272
    • Irie, K.1    Murayama, Y.2    Saguchi, T.3
  • 8
    • 64649104104 scopus 로고    scopus 로고
    • Efficacy of DynaCT digital angiography in the detection of the fistulous point of dural arteriovenous fistulas
    • Hiu T, Kitagawa N, Morikawa M, et al. Efficacy of DynaCT digital angiography in the detection of the fistulous point of dural arteriovenous fistulas. AJNR Am J Neuroradiol. 2009;30(3):487-491.
    • (2009) AJNR Am J Neuroradiol , vol.30 , Issue.3 , pp. 487-491
    • Hiu, T.1    Kitagawa, N.2    Morikawa, M.3
  • 10
    • 0032471963 scopus 로고    scopus 로고
    • Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: Comparison with contrast-enhanced CT and spin-echo MR
    • Hirai T, Korogi Y, Hamatake S, et al. Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: comparison with contrast-enhanced CT and spin-echo MR. AJNR Am J Neuroradiol. 1998;19(2):253-259.
    • (1998) AJNR Am J Neuroradiol , vol.19 , Issue.2 , pp. 253-259
    • Hirai, T.1    Korogi, Y.2    Hamatake, S.3
  • 12
    • 0018358202 scopus 로고
    • Balloon catheters for investigating carotid cavernous fistula
    • Berenstein A, Kricheff II. Balloon catheters for investigating carotid cavernous fistula. Radiology. 1979;132(3):762-764.
    • (1979) Radiology , vol.132 , Issue.3 , pp. 762-764
    • Berenstein, A.1    Kricheff, I.I.2
  • 13
    • 0018150933 scopus 로고
    • A safe technique for the precise localization of carotid-cavernous fistula during balloon obliteration: Technical note
    • Cares HL, Roberson GH, Grand W, Hopkins LN. A safe technique for the precise localization of carotid-cavernous fistula during balloon obliteration: technical note. J Neurosurg. 1978;49(1):146-149.
    • (1978) J Neurosurg , vol.49 , Issue.1 , pp. 146-149
    • Cares, H.L.1    Roberson, G.H.2    Grand, W.3    Hopkins, L.N.4
  • 14
    • 0041312327 scopus 로고    scopus 로고
    • Traumatic carotidcavernous fistula identified by three-dimensional digital subtraction angiography: Technical note
    • Ishida F, Kojima T, Kawaguchi K, Hoshino T, Murao K, Taki W. Traumatic carotidcavernous fistula identified by three-dimensional digital subtraction angiography: technical note. Neurol Med Chir (Tokyo). 2003;43(7):369-373.
    • (2003) Neurol Med Chir (Tokyo) , vol.43 , Issue.7 , pp. 369-373
    • Ishida, F.1    Kojima, T.2    Kawaguchi, K.3    Hoshino, T.4    Murao, K.5    Taki, W.6
  • 15
    • 20444481424 scopus 로고    scopus 로고
    • Endovascular occlusion of direct carotid cavernous fistula with detachable balloons: Usefulness of 3D angiography
    • Kwon BJ, Han MH, Kang HS, Chang KH. Endovascular occlusion of direct carotid cavernous fistula with detachable balloons: usefulness of 3D angiography. Neuroradiology. 2005;47(4):271-281.
    • (2005) Neuroradiology , vol.47 , Issue.4 , pp. 271-281
    • Kwon, B.J.1    Han, M.H.2    Kang, H.S.3    Chang, K.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.