메뉴 건너뛰기




Volumn 21, Issue 4, 2000, Pages 712-716

Carotid-cavernous fistulas: Diagnosis with spiral CT angiography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN ANGIOGRAPHY; CAROTID CAVERNOUS FISTULA; CASE REPORT; CLINICAL FEATURE; DIAGNOSTIC VALUE; DIGITAL SUBTRACTION ANGIOGRAPHY; FEMALE; HUMAN; IMAGE ANALYSIS; MALE; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 0034032592     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (50)

References (12)
  • 1
    • 0029145137 scopus 로고
    • Computed tomographic angiography for the evaluation of carotid artery stenosis
    • Leclere X, Godefroy O, Pruvo JP, Leys D. Computed tomographic angiography for the evaluation of carotid artery stenosis. Stroke 1995;26:1577-1581
    • (1995) Stroke , vol.26 , pp. 1577-1581
    • Leclere, X.1    Godefroy, O.2    Pruvo, J.P.3    Leys, D.4
  • 3
    • 0033014247 scopus 로고    scopus 로고
    • Internal carotid arterial stenosis: CT angiography with volume rendering
    • Leclere X, Godefroy O, Lucas C. et al. Internal carotid arterial stenosis: CT angiography with volume rendering. Radiology 1999;210:673-682
    • (1999) Radiology , vol.210 , pp. 673-682
    • Leclere, X.1    Godefroy, O.2    Lucas, C.3
  • 4
    • 0028087678 scopus 로고
    • Evaluation of cerebral aneurysms with helical CT: Correlation with conventional angiography and MR angiography
    • Schwurtz RB, Tice HM, Houten SM, Hsu L, Stieg PE. Evaluation of cerebral aneurysms with helical CT: correlation with conventional angiography and MR angiography. Radiology 1994; 192:717-722
    • (1994) Radiology , vol.192 , pp. 717-722
    • Schwurtz, R.B.1    Tice, H.M.2    Houten, S.M.3    Hsu, L.4    Stieg, P.E.5
  • 5
    • 0029093342 scopus 로고
    • Evaluation of the circle of Willis with three-dimensional CT angiography in patients with suspected intracranial aneurysms
    • Alberico RA, Patel M, Casey S, Jacobs B, Maguire W, Decker R. Evaluation of the circle of Willis with three-dimensional CT angiography in patients with suspected intracranial aneurysms. AJNR Am J Neuroradiol 1995;16:1571-1578
    • (1995) AJNR Am J Neuroradiol , vol.16 , pp. 1571-1578
    • Alberico, R.A.1    Patel, M.2    Casey, S.3    Jacobs, B.4    Maguire, W.5    Decker, R.6
  • 8
    • 0023197225 scopus 로고
    • Dural fistulas involving the cavernous sinus: Results of treatment in 30 patients
    • Halbach V, Higashida R, Hieshima G, Reicher M, Norman D, Newton T. Durai fistulas involving the cavernous sinus: results of treatment in 30 patients. Radiology 1987;163:437-442
    • (1987) Radiology , vol.163 , pp. 437-442
    • Halbach, V.1    Higashida, R.2    Hieshima, G.3    Reicher, M.4    Norman, D.5    Newton, T.6
  • 9
    • 0024327152 scopus 로고
    • Dynamic CT of the laterosellar extradural venous spaces
    • Bonneville JF, Cattin F, Racle A, et al. Dynamic CT of the laterosellar extradural venous spaces. AJNR Am J Neumnuliol 1989;10:535-542
    • (1989) AJNR Am J Neumnuliol , vol.10 , pp. 535-542
    • Bonneville, J.F.1    Cattin, F.2    Racle, A.3
  • 10
    • 0015465148 scopus 로고
    • Les affluents du plexus caverneux
    • Theron J. Les affluents du plexus caverneux. Neurochirurgie 1972;18:623-638
    • (1972) Neurochirurgie , vol.18 , pp. 623-638
    • Theron, J.1
  • 11
    • 0029150684 scopus 로고
    • CT angiography with volume rendering: Imaging findings
    • Kuszyk B, Heath D, Ney D, et al. CT angiography with volume rendering: imaging findings. AJR Am J Roentgenol 1995;165: 445-448
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 445-448
    • Kuszyk, B.1    Heath, D.2    Ney, D.3
  • 12
    • 0031030288 scopus 로고    scopus 로고
    • CT angiography: Thoracic vascular imaging with interactive volume rendering technique
    • Johnson P, Heath D, Kuszyk B, Fishman. CT angiography: thoracic vascular imaging with interactive volume rendering technique. J Comput Assist Tomogr 1997;21:110-114
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 110-114
    • Johnson, P.1    Heath, D.2    Kuszyk, B.3    Fishman4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.