-
1
-
-
0038546369
-
Feasibility of Using Peroneal Nerve Recordings for Deriving Stimulation Timing in a Foot Drop Correction System
-
Hansen, M.; Haugland, M.K.; Sepulveda, F. Feasibility of Using Peroneal Nerve Recordings for Deriving Stimulation Timing in a Foot Drop Correction System. Neuromodulation 2003, 6, 68-77.
-
(2003)
Neuromodulation
, vol.6
, pp. 68-77
-
-
Hansen, M.1
Haugland, M.K.2
Sepulveda, F.3
-
2
-
-
33750339324
-
Gait Event Detection Using Linear Accelerometers or Angular Velocity Transducers in Able-Bodied and Spinal-Cord Injured Individuals
-
Jasiewicz, J.M.; Allum, J.H.J.; Middleton, J.W.; Barriskill, A.; Condie, P.; Purcell, B.; Li, R.C.T. Gait Event Detection Using Linear Accelerometers or Angular Velocity Transducers in Able-Bodied and Spinal-Cord Injured Individuals. Gait Posture 2006, 24, 502-509.
-
(2006)
Gait Posture
, vol.24
, pp. 502-509
-
-
Jasiewicz, J.M.1
Allum, J.H.J.2
Middleton, J.W.3
Barriskill, A.4
Condie, P.5
Purcell, B.6
Li, R.C.T.7
-
3
-
-
0034065740
-
Algorithms to Determine Event Timing During Normal Walking Using Kinematic Data
-
Hreljac, A.; Marshall, R.N. Algorithms to Determine Event Timing During Normal Walking Using Kinematic Data. J. Biomech. 2000, 33, 783-786.
-
(2000)
J. Biomech
, vol.33
, pp. 783-786
-
-
Hreljac, A.1
Marshall, R.N.2
-
4
-
-
0033213744
-
Limb Locomotion-Speed Distribution Analysis as a New Method for Stance Phase Detection
-
Peham, C.; Scheidl, M.; Licka, T. Limb Locomotion-Speed Distribution Analysis as a New Method for Stance Phase Detection. J. Biomech. 1999, 32, 1119-1124.
-
(1999)
J. Biomech
, vol.32
, pp. 1119-1124
-
-
Peham, C.1
Scheidl, M.2
Licka, T.3
-
5
-
-
57649216012
-
Foot Contact Event Detection Using Kinematic Data in Cerebral Palsy Children and Normal Adults Gait
-
Desailly, E.; Daniel, Y.; Sardain, P.; Lacouture, P. Foot Contact Event Detection Using Kinematic Data in Cerebral Palsy Children and Normal Adults Gait. Gait Posture 2009, 29, 76-80.
-
(2009)
Gait Posture
, vol.29
, pp. 76-80
-
-
Desailly, E.1
Daniel, Y.2
Sardain, P.3
Lacouture, P.4
-
6
-
-
17444373518
-
Assessment and Validation of a Simple Automated Method for the Detection of Gait Events and Intervals
-
Ghoussayni, S.N.; Stevens, C.H.H.; Durham, S.; Ewins, D.J. Assessment and Validation of a Simple Automated Method for the Detection of Gait Events and Intervals. Gait Posture 2003, 20, 266-272.
-
(2003)
Gait Posture
, vol.20
, pp. 266-272
-
-
Ghoussayni, S.N.1
Stevens, C.H.H.2
Durham, S.3
Ewins, D.J.4
-
7
-
-
49449086743
-
Online Gait Event Detection Using a Large Force Platform Embedded in a Treadmill
-
Roerdink, M.; Coolen, B.; Clairbois, B.E.; Lamoth, C.J.C.; Beek, P.J. Online Gait Event Detection Using a Large Force Platform Embedded in a Treadmill. J. Biomech. 2008, 41, 2628-2632.
-
(2008)
J. Biomech
, vol.41
, pp. 2628-2632
-
-
Roerdink, M.1
Coolen, B.2
Clairbois, B.E.3
Lamoth, C.J.C.4
Beek, P.J.5
-
8
-
-
37049028981
-
Concurrent Validity and Intrasession Reliability of the IDEEA Accelerometry System for the Quantification of Spatiotemporal Gait Parameters
-
Maffiuletti, N.A.; Gorelick, M.; Kramers-de Quervain, I.; Bizzini, M.; Munzinger, J.P.; Tomasetti, S.; Stacoff, A. Concurrent Validity and Intrasession Reliability of the IDEEA Accelerometry System for the Quantification of Spatiotemporal Gait Parameters. Gait Posture 2008, 27, 160-163.
-
(2008)
Gait Posture
, vol.27
, pp. 160-163
-
-
Maffiuletti, N.A.1
Gorelick, M.2
Kramers-de Quervain, I.3
Bizzini, M.4
Munzinger, J.P.5
Tomasetti, S.6
Stacoff, A.7
-
9
-
-
14844337561
-
Assessment of Walking Features from Foot Inertial Sensing
-
Sabatini, A.M.; Martelloni, C.; Scapellato, S.; Cavallo, F. Assessment of Walking Features from Foot Inertial Sensing. IEEE Trans. Biomed. Eng. 2005, 52, 486-494.
-
(2005)
IEEE Trans. Biomed. Eng.
, vol.52
, pp. 486-494
-
-
Sabatini, A.M.1
Martelloni, C.2
Scapellato, S.3
Cavallo, F.4
-
10
-
-
44149090529
-
Predicting Lower Limb Joint Kinematics Using Wearable Motion Sensors
-
Findlow, A.; Goulermas, J.Y.; Nester, C.; Howard, D.; Kenney, L.P.J. Predicting Lower Limb Joint Kinematics Using Wearable Motion Sensors. Gait Posture 2008, 28, 120-126.
-
(2008)
Gait Posture
, vol.28
, pp. 120-126
-
-
Findlow, A.1
Goulermas, J.Y.2
Nester, C.3
Howard, D.4
Kenney, L.P.J.5
-
11
-
-
34250629373
-
An Inertial and Magnetic Sensor Based Technique for Joint Angle Measurement
-
O'Donovan, K.J.; Kamnik, R.; O'Keeffe, D.T.; Lyons, G.M. An Inertial and Magnetic Sensor Based Technique for Joint Angle Measurement. J. Biomech. 2007, 40, 2604-2611.
-
(2007)
J. Biomech.
, vol.40
, pp. 2604-2611
-
-
O'Donovan, K.J.1
Kamnik, R.2
O'Keeffe, D.T.3
Lyons, G.M.4
-
12
-
-
15944368885
-
Performance of Orientation Sensor for Use With A Functional Electrical Stimulation Mobility System
-
Simcox, S.; Parker, S.; Davis, G.M.; Smith, R.W.; Middleton, J.W. Performance of Orientation Sensor for Use With A Functional Electrical Stimulation Mobility System. J. Biomech. 2005, 38, 1185-1190.
-
(2005)
J. Biomech
, vol.38
, pp. 1185-1190
-
-
Simcox, S.1
Parker, S.2
Davis, G.M.3
Smith, R.W.4
Middleton, J.W.5
-
13
-
-
0036208446
-
Accelerometer and Rate Gyroscope Measurement of Kinematics: An Inexpensive Alternative to Optical Motion Analysis Systems
-
Mayagoitia, R.; Nene, A.; Veltink, P.H. Accelerometer and Rate Gyroscope Measurement of Kinematics: An Inexpensive Alternative to Optical Motion Analysis Systems. J. Biomech. 2002, 35, 537-542.
-
(2002)
J. Biomech.
, vol.35
, pp. 537-542
-
-
Mayagoitia, R.1
Nene, A.2
Veltink, P.H.3
-
14
-
-
0030176016
-
Application of Tilt Sensors in Functional Electrical Stimulation
-
Dai, R.; Stein, R.B.; Andrews, B.J.; James, K.B.; Wieler, M. Application of Tilt Sensors in Functional Electrical Stimulation. IEEE Trans. Rehabil. Eng. 1996, 4, 63-72.
-
(1996)
IEEE Trans. Rehabil. Eng.
, vol.4
, pp. 63-72
-
-
Dai, R.1
Stein, R.B.2
Andrews, B.J.3
James, K.B.4
Wieler, M.5
-
15
-
-
0034209010
-
Sensor Systems for Lower Limb Functional Electrical Stimulation (FES) Control
-
Williamson, R.; Andrews, B. Sensor Systems for Lower Limb Functional Electrical Stimulation (FES) Control. Med. Eng. Phys. 2000, 22, 313-325.
-
(2000)
Med. Eng. Phys.
, vol.22
, pp. 313-325
-
-
Williamson, R.1
Andrews, B.2
-
16
-
-
16344386255
-
Automated Estimation of Initial and Terminal Contact Timing Using Accelerometers; Development and Validation in Transtibial Amputees and Controls
-
Selles, R.; Formanoy, M.A.G.; Bussmann, J.B.J.; Janssens, P.J.; Stam, H.J. Automated Estimation of Initial and Terminal Contact Timing Using Accelerometers; Development and Validation in Transtibial Amputees and Controls. IEEE Trans. Neural Syst. Rehabil. Eng. 2005, 13, 81-88.
-
(2005)
IEEE Trans. Neural Syst. Rehabil. Eng.
, vol.13
, pp. 81-88
-
-
Selles, R.1
Formanoy, M.A.G.2
Bussmann, J.B.J.3
Janssens, P.J.4
Stam, H.J.5
-
17
-
-
70349251128
-
Real-Time Gait Event Detection Using Wearable Sensors
-
Hanlon, M.; Anderson, R. Real-Time Gait Event Detection Using Wearable Sensors. Gait Posture 2009, 30, 523-527.
-
(2009)
Gait Posture
, vol.30
, pp. 523-527
-
-
Hanlon, M.1
Anderson, R.2
-
18
-
-
0036221730
-
Spatio-Temporal Parameters of Gait Measured by an Ambulatory System Using Miniature Gyroscopes
-
Aminian, K.; Najafi, B.; Bula, C.; Leyvraz, P.F.; Roberts, P. Spatio-Temporal Parameters of Gait Measured by an Ambulatory System Using Miniature Gyroscopes. J. Biomech. 2002, 35, 689-699.
-
(2002)
J. Biomech.
, vol.35
, pp. 689-699
-
-
Aminian, K.1
Najafi, B.2
Bula, C.3
Leyvraz, P.F.4
Roberts, P.5
-
19
-
-
84876624201
-
-
PhD Thesis, University of Surrey, Guildford, UK, Available online, (accessed on 14 March
-
Ghoussayni, S.N. Application of Angular Rate Gyroscopes as Sensors In Electrical Orthoses for Foot Drop Correction; PhD Thesis, University of Surrey, Guildford, UK, 2004; Available online: https://ethos.bl.uk (accessed on 14 March 2010).
-
(2004)
Application of Angular Rate Gyroscopes As Sensors in Electrical Orthoses for Foot Drop Correction
-
-
Ghoussayni, S.N.1
-
20
-
-
0031213584
-
Long-Term Unrestrained Measurement of Stride Length and Walking Velocity Utilizing a Piezoelectric Gyroscope
-
Miyazaki, S. Long-Term Unrestrained Measurement of Stride Length and Walking Velocity Utilizing a Piezoelectric Gyroscope. IEEE. Trans. Biomed. Eng. 1997, 44, 753-759.
-
(1997)
IEEE. Trans. Biomed. Eng.
, vol.44
, pp. 753-759
-
-
Miyazaki, S.1
-
21
-
-
4344596524
-
Ambulatory System for the Quantitative and Qualitative Analysis of Gait and Posture in Chronic Pain Patients Treated With Spinal Cord Stimulation
-
Paraschiv-Ionescu, A.; Buchser, E.E.; Rutschmann, B.; Najafi, B.; Aminian, K. Ambulatory System for the Quantitative and Qualitative Analysis of Gait and Posture in Chronic Pain Patients Treated With Spinal Cord Stimulation. Gait Posture 2004, 20, 113-125.
-
(2004)
Gait Posture
, vol.20
, pp. 113-125
-
-
Paraschiv-Ionescu, A.1
Buchser, E.E.2
Rutschmann, B.3
Najafi, B.4
Aminian, K.5
-
22
-
-
70849088897
-
Classifying Human Leg Motions with Uniaxial Piezoelectric Gyroscopes
-
Tuncel, O.; Altun, K.; Barshan, B. Classifying Human Leg Motions with Uniaxial Piezoelectric Gyroscopes. Sensors 2009, 9, 8508-8546.
-
(2009)
Sensors
, vol.9
, pp. 8508-8546
-
-
Tuncel, O.1
Altun, K.2
Barshan, B.3
-
23
-
-
77954766519
-
A Control System for a Lower Limb Prosthesis or Orthosis
-
2006/024876 A2
-
Moser, D.; Ewins, D. A Control System for a Lower Limb Prosthesis or Orthosis. Worldwide Patent 2006/024876 A2, 2006.
-
(2006)
Worldwide Patent
-
-
Moser, D.1
Ewins, D.2
-
24
-
-
0032170864
-
Virtual Artificial Sensor Technique for Functional Electrical Stimulation
-
Tong, K.; Granat, M.H. Virtual Artificial Sensor Technique for Functional Electrical Stimulation. Med. Eng. Phys. 1998, 20, 458-468.
-
(1998)
Med. Eng. Phys.
, vol.20
, pp. 458-468
-
-
Tong, K.1
Granat, M.H.2
-
25
-
-
0000063574
-
A Review of Body Segmental Displacement, Velocity and Acceleration in Human Gait
-
Craik, R.L., Oatis, C.A., Eds.; Mosby: St Louis, MO, USA
-
Wu, G. A Review of Body Segmental Displacement, Velocity and Acceleration in Human Gait. In Gait Analysis Theory and Application; Craik, R.L., Oatis, C.A., Eds.; Mosby: St Louis, MO, USA, 1995; pp. 205-222.
-
(1995)
Gait Analysis Theory and Application
, pp. 205-222
-
-
Wu, G.1
-
26
-
-
2942627630
-
Evaluation of an Ambulatory System for Gait Analysis in Hip Osteoarthritis and after Total Hip Replacement
-
Aminian, K.; Trevisan, C.; Najafi, B.; Dejnabadi, H.; Frigo, C.; Pavan, E.; Telonio, A.; Cerati, F.; Marinoni, E.C.; Robert, P.; Leyvraz, P.F. Evaluation of an Ambulatory System for Gait Analysis in Hip Osteoarthritis and after Total Hip Replacement. Gait Posture 2004, 20, 102-107.
-
(2004)
Gait Posture
, vol.20
, pp. 102-107
-
-
Aminian, K.1
Trevisan, C.2
Najafi, B.3
Dejnabadi, H.4
Frigo, C.5
Pavan, E.6
Telonio, A.7
Cerati, F.8
Marinoni, E.C.9
Robert, P.10
Leyvraz, P.F.11
-
27
-
-
3242658261
-
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
-
Salarian, A.; Russmann, H.; Vingerhoets, F.J.G.; Dehollian, C.; Blanc, Y.; Burkhard, P.; Aminian, K. Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring. IEEE Trans. Biomed. Eng. 2004, 51, 1434-1443.
-
(2004)
IEEE Trans. Biomed. Eng.
, vol.51
, pp. 1434-1443
-
-
Salarian, A.1
Russmann, H.2
Vingerhoets, F.J.G.3
Dehollian, C.4
Blanc, Y.5
Burkhard, P.6
Aminian, K.7
-
28
-
-
77954800965
-
An Experimental Evaluation of the Gyroscope as a Sensor in FES Foot-Drop Correction Systems
-
Vienna, Austria, September 12-15
-
Ghoussayni, S.N.; Henty, J.R.; Wood, D.E.; Ewins, D.J. An Experimental Evaluation of the Gyroscope as a Sensor in FES Foot-Drop Correction Systems. In Proceedings of the 7th Vienna International Workshop on Functional Electrical Stimulation, Vienna, Austria, September 12-15, 2001; pp. 200-203.
-
(2001)
Proceedings of the 7th Vienna International Workshop on Functional Electrical Stimulation
, pp. 200-203
-
-
Ghoussayni, S.N.1
Henty, J.R.2
Wood, D.E.3
Ewins, D.J.4
-
29
-
-
33744542378
-
The Effects of Sloped Surfaces on Locomotion: A Kinematic And Kinetic Analysis
-
Lay, A.N.; Hass, C.J.; Gregor, R.J. The Effects of Sloped Surfaces on Locomotion: A Kinematic And Kinetic Analysis. J. Biomech. 2006, 39, 1621-1628.
-
(2006)
J. Biomech.
, vol.39
, pp. 1621-1628
-
-
Lay, A.N.1
Hass, C.J.2
Gregor, R.J.3
-
30
-
-
17444404200
-
Locomotor Adaptations for Changes in the Slope of the Walking Surface
-
Prentice, S.D.; Hasler, E.N.; Groves, J.J.; Frank, J.S. Locomotor Adaptations for Changes in the Slope of the Walking Surface. Gait Posture 2004, 20, 255-265.
-
(2004)
Gait Posture
, vol.20
, pp. 255-265
-
-
Prentice, S.D.1
Hasler, E.N.2
Groves, J.J.3
Frank, J.S.4
-
31
-
-
0029256611
-
Kinematic and Kinetic Comparison of Downhill and Level Walking
-
Kuster, M.; Sakurai, S.; Wood, G.A. Kinematic and Kinetic Comparison of Downhill and Level Walking. Clin. Biomech. 1995, 10, 79-84.
-
(1995)
Clin. Biomech.
, vol.10
, pp. 79-84
-
-
Kuster, M.1
Sakurai, S.2
Wood, G.A.3
-
32
-
-
84876595992
-
-
PhD Thesis, University of Surrey, Guildford, UK, Available online,.(accessed on 15 March)
-
Henty, J. Detection of Gait Events Using a Gyroscope Sensor in FES Drop Foot Correction; PhD Thesis, University of Surrey, Guildford, UK, 2003; Available online: https://ethos.bl.uk.(accessed on 15 March 2010).
-
(2003)
Detection of Gait Events Using a Gyroscope Sensor in FES Drop Foot Correction
-
-
Henty, J.1
-
33
-
-
0032998285
-
A Practical Gait Analysis System Using Gyroscopes
-
Tong, K.; Granat, M.H. A Practical Gait Analysis System Using Gyroscopes. Med. Eng. Phys. 1999, 21, 87-94.
-
(1999)
Med. Eng. Phys.
, vol.21
, pp. 87-94
-
-
Tong, K.1
Granat, M.H.2
-
34
-
-
0032955171
-
Assesment of Rectus Femoris Function During Initial Swing Phase
-
Nene, A.; Mayagoitia, R.; Veltink, P.H. Assesment of Rectus Femoris Function During Initial Swing Phase. Gait Posture 1999, 9, 1-9.
-
(1999)
Gait Posture
, vol.9
, pp. 1-9
-
-
Nene, A.1
Mayagoitia, R.2
Veltink, P.H.3
-
36
-
-
54049101148
-
Detection of Gait Events Using an F-Scan in-Shoe Pressure Measurement System
-
Catalfamo, P.; Moser, D.; Ghoussayni, S.N.; Ewins, D.J. Detection of Gait Events Using an F-Scan in-Shoe Pressure Measurement System. Gait Posture 2008, 28, 420-426.
-
(2008)
Gait Posture
, vol.28
, pp. 420-426
-
-
Catalfamo, P.1
Moser, D.2
Ghoussayni, S.N.3
Ewins, D.J.4
-
37
-
-
0003752083
-
-
2nd ed.; Chapman and Hall: Boca Raton, FL, USA
-
Taylor, J.K.; Cihon, C. Statistical Techniques for Data Analysis, 2nd ed.; Chapman and Hall: Boca Raton, FL, USA, 2004.
-
(2004)
Statistical Techniques for Data Analysis
-
-
Taylor, J.K.1
Cihon, C.2
-
38
-
-
0035992805
-
Evaluation of Force-Sensing Resistors for Gait Event Detection to Trigger Electrical Stimulation to Improve Walking in the Child with Cerebral Palsy
-
Smith, B.T.; Coiro, D.J.; Finson, R.; Betz, R.R.; McCarthy, J. Evaluation of Force-Sensing Resistors for Gait Event Detection to Trigger Electrical Stimulation to Improve Walking in the Child with Cerebral Palsy. IEEE Trans. Neural Syst. Reh. Eng. 2002, 10, 22-29.
-
(2002)
IEEE Trans. Neural Syst. Reh. Eng.
, vol.10
, pp. 22-29
-
-
Smith, B.T.1
Coiro, D.J.2
Finson, R.3
Betz, R.R.4
McCarthy, J.5
-
39
-
-
0030728291
-
Biomechanics of Descending Ramps
-
Redfern, M.S.; Di Pasquale, J. Biomechanics of Descending Ramps. Gait Posture 1997, 6, 119-125.
-
(1997)
Gait Posture
, vol.6
, pp. 119-125
-
-
Redfern, M.S.1
di Pasquale, J.2
-
40
-
-
41949126495
-
Effect of Speed on Kinematic, Kinetic, Electromyographic and Energetic Reference Values during Treadmill Walking
-
Stoquart, G.; Detrembleur, C.; Lejeune, T. Effect of Speed on Kinematic, Kinetic, Electromyographic and Energetic Reference Values during Treadmill Walking. Neurophysiol. Clin. 2008, 38, 105-116.
-
(2008)
Neurophysiol. Clin.
, vol.38
, pp. 105-116
-
-
Stoquart, G.1
Detrembleur, C.2
Lejeune, T.3
-
41
-
-
0028485797
-
Joint Angle Parameters in Gait: Reference Data for Normal Subjects, 10-79 Years of Age
-
Oberg, T.; Karsznia, A.; Oberg, K. Joint Angle Parameters in Gait: Reference Data for Normal Subjects, 10-79 Years of Age. J. Rehabil. Res. Develop. 1994, 31, 199-213.
-
(1994)
J. Rehabil. Res. Develop.
, vol.31
, pp. 199-213
-
-
Oberg, T.1
Karsznia, A.2
Oberg, K.3
-
42
-
-
0031463330
-
Gait Analysis During Treadmill and Overground Locomotion in Children and Adults
-
Stolze, H.; Kuhtz-Buschbeck, J.P.; Mondwurf, C.; Boczek-Funcke, A.; Jöhnk, K.; Deuschl, G.; Illert, M. Gait Analysis During Treadmill and Overground Locomotion in Children and Adults. Electroencephalogr. Motor Control. 1997, 105, 490-497.
-
(1997)
Electroencephalogr. Motor Control.
, vol.105
, pp. 490-497
-
-
Stolze, H.1
Kuhtz-Buschbeck, J.P.2
Mondwurf, C.3
Boczek-Funcke, A.4
Jöhnk, K.5
Deuschl, G.6
Illert, M.7
-
43
-
-
0020965948
-
Changes in Knee Function Associated with Treadmill Ambulation
-
Strathy, G.M.; Chao, E.Y.; Laughman, R.K. Changes in Knee Function Associated with Treadmill Ambulation. J. Biomech. 1983, 16, 517-522.
-
(1983)
J. Biomech.
, vol.16
, pp. 517-522
-
-
Strathy, G.M.1
Chao, E.Y.2
Laughman, R.K.3
-
44
-
-
0032168612
-
A Kinematic Comparison of Overground and Treadmill Walking
-
Alton, F.; Baldey, L.; Caplan, S.; Morrissey, M.C. A Kinematic Comparison of Overground and Treadmill Walking. Clin. Biomech. 1998, 13, 434-440.
-
(1998)
Clin. Biomech.
, vol.13
, pp. 434-440
-
-
Alton, F.1
Baldey, L.2
Caplan, S.3
Morrissey, M.C.4
-
45
-
-
34247211061
-
A Kinematic and Kinetic Comparison of Overground and Treadmill Walking in Healthy Subjects
-
Riley, P.O.; Paolini, G.; Della Croce, U.; Paylo, K.W.; Kerrigan, D.C. A Kinematic and Kinetic Comparison of Overground and Treadmill Walking in Healthy Subjects. Gait Posture 2007, 26, 17-24.
-
(2007)
Gait Posture
, vol.26
, pp. 17-24
-
-
Riley, P.O.1
Paolini, G.2
della Croce, U.3
Paylo, K.W.4
Kerrigan, D.C.5
-
46
-
-
57349160390
-
Kinematic, Kinetic and Metabolic Parameters of Treadmill versus Overground Walking in Healthy Older Adults
-
Parvataneni, K.; Ploeg, L.; Olney, S.J.; Brouwer, B. Kinematic, Kinetic and Metabolic Parameters of Treadmill versus Overground Walking in Healthy Older Adults. Clin. Biomech. 2009, 24, 95-100.
-
(2009)
Clin. Biomech.
, vol.24
, pp. 95-100
-
-
Parvataneni, K.1
Ploeg, L.2
Olney, S.J.3
Brouwer, B.4
-
47
-
-
0032862031
-
Patients' Perception of the Odstock Dropped Foot Stimulator (ODFS)
-
Taylor, P.N.; Burridge, J.H.; Dunkerley, A.L.; Lamb, A.; Wood, D.E.; Norton, J.A.; Swain, I.D. Patients' Perception of the Odstock Dropped Foot Stimulator (ODFS). Clin. Rehabil. 1999, 13, 439-446.
-
(1999)
Clin. Rehabil.
, vol.13
, pp. 439-446
-
-
Taylor, P.N.1
Burridge, J.H.2
Dunkerley, A.L.3
Lamb, A.4
Wood, D.E.5
Norton, J.A.6
Swain, I.D.7
-
48
-
-
0242662564
-
The Use of Accelerometry to Detect Heel Contact Events for Use as a Sensor in FES Assisted Walking
-
Mansfield, A.; Lyons, G.M. The Use of Accelerometry to Detect Heel Contact Events for Use as a Sensor in FES Assisted Walking. Med. Eng. Phys. 2003, 25, 879-885.
-
(2003)
Med. Eng. Phys.
, vol.25
, pp. 879-885
-
-
Mansfield, A.1
Lyons, G.M.2
-
49
-
-
70350663138
-
Control of Triceps Surae Stimulation Based on Shank Orientation Using a Uniaxial Gyroscope
-
Bournemouth, UK, September
-
Monaghan, C.C.; Veltink, P.H.; Bultstra, G.; Droog, E.; Kotiadis, D.; Van Riel, W. Control of Triceps Surae Stimulation Based on Shank Orientation Using a Uniaxial Gyroscope. In Proceedings of the 9th Annual Conference of the International FES Society, Bournemouth, UK, September 2004; pp. 413-415.
-
(2004)
Proceedings of the 9th Annual Conference of the International FES Society
, pp. 413-415
-
-
Monaghan, C.C.1
Veltink, P.H.2
Bultstra, G.3
Droog, E.4
Kotiadis, D.5
van Riel, W.6
-
50
-
-
0034757149
-
A Reliable Gait Phase Detection System
-
Pappas, I.P.I.; Popovic, M.R.; Keller, T.; Dietz, V.; Morari, M. A Reliable Gait Phase Detection System. IEEE Trans. Neural Syst. Reh. Eng. 2001, 9, 113-125.
-
(2001)
IEEE Trans. Neural Syst. Reh. Eng.
, vol.9
, pp. 113-125
-
-
Pappas, I.P.I.1
Popovic, M.R.2
Keller, T.3
Dietz, V.4
Morari, M.5
-
51
-
-
0006436522
-
Comparison of Foot Switch and Hand Switch Triggered FES Correction of Foot Drop
-
Vienna, Austria, September 22-24
-
Ott, E.; Munih, M.; Benko, H.; Kralj, A. Comparison of Foot Switch and Hand Switch Triggered FES Correction of Foot Drop. In Proceedings of the 6th Vienna International Workshop on Functional Electrical Stimulation, Vienna, Austria, September 22-24, 1998; pp. 193-196.
-
(1998)
Proceedings of the 6th Vienna International Workshop on Functional Electrical Stimulation
, pp. 193-196
-
-
Ott, E.1
Munih, M.2
Benko, H.3
Kralj, A.4
|