메뉴 건너뛰기




Volumn 38, Issue 5, 2005, Pages 1185-1190

Performance of orientation sensors for use with a functional electrical stimulation mobility system

Author keywords

Accelerometer; Closed loop control; Gyroscope; Kinematics; Sensors

Indexed keywords

BIOLOGICAL ORGANS; BIOMECHANICS; CAMERAS; GYROSCOPES; SIGNAL PROCESSING; TIME DOMAIN ANALYSIS;

EID: 15944368885     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2004.05.026     Document Type: Article
Times cited : (35)

References (15)
  • 2
    • 0033064275 scopus 로고    scopus 로고
    • Paraplegia: Prolonged standing using closed-loop functional electrical stimulation and andrews ankle-foot orthosis
    • Davis R., Houdayer T., Andrews B.Barriskill, A. Paraplegia. Prolonged standing using closed-loop functional electrical stimulation and andrews ankle-foot orthosis Artificial Organs. 23:1999;418-420
    • (1999) Artificial Organs , vol.23 , pp. 418-420
    • Davis, R.1    Houdayer, T.2    Andrews, B.3    Barriskill, A.4
  • 3
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E.S., Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions. Application to the knee Journal of Biomechnical Engineering. 105:1983;136-144
    • (1983) Journal of Biomechnical Engineering , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 5
    • 0036208446 scopus 로고    scopus 로고
    • Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems
    • Mayagoitia R.E., Nene A.V., Veltink P.H. Accelerometer and rate gyroscope measurement of kinematics. An inexpensive alternative to optical motion analysis systems Journal of Biomechnics. 35:2002;537-542
    • (2002) Journal of Biomechnics , vol.35 , pp. 537-542
    • Mayagoitia, R.E.1    Nene, A.V.2    Veltink, P.H.3
  • 6
    • 0031213584 scopus 로고    scopus 로고
    • Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope
    • Miyazaki S. Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope. IEEE Transactions on Biomedical Engineering. 44:1997;753-759
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , pp. 753-759
    • Miyazaki, S.1
  • 11
    • 0032998285 scopus 로고    scopus 로고
    • A practical gait analysis system using gyroscopes
    • Tong K.Granat, M.H. A practical gait analysis system using gyroscopes. Medical Engineering Physics. 21:1999;87-94
    • (1999) Medical Engineering Physics , vol.21 , pp. 87-94
    • Tong, K.G.1    H., M.2
  • 12
    • 0025661988 scopus 로고
    • Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
    • Willemsen A.T., Bloemhof F., Boom H.B. Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation. IEEE Transactions Biomedical Engineering. 37:1990;1201-1208
    • (1990) IEEE Transactions Biomedical Engineering , vol.37 , pp. 1201-1208
    • Willemsen, A.T.1    Bloemhof, F.2    Boom, H.B.3
  • 13
    • 0034960616 scopus 로고    scopus 로고
    • Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
    • Williamson R., Andrews B.J. Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes. Medical and Biological Engineering and Computing. 39:2001;294-302
    • (2001) Medical and Biological Engineering and Computing , vol.39 , pp. 294-302
    • Williamson, R.1    Andrews, B.J.2
  • 14
  • 15
    • 0034209010 scopus 로고    scopus 로고
    • Sensor systems for lower limb functional electrical stimulation (FES) control
    • Williamson R., Andrews B.J. Sensor systems for lower limb functional electrical stimulation (FES) control. Medical Engineering and Physics. 22:2000;313-325
    • (2000) Medical Engineering and Physics , vol.22 , pp. 313-325
    • Williamson, R.1    Andrews, B.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.