메뉴 건너뛰기




Volumn 81, Issue 8, 2010, Pages 1014-1018

Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the AirWay Scope, and the gum elastic bougie: A manikin study

Author keywords

Airway; AirWay Scope; Cardiopulmonary resuscitation; Gum elastic bougie; Intubation; Macintosh laryngoscope

Indexed keywords

AIRWAY; ANESTHESIST; ARTICLE; AUDIOVISUAL EQUIPMENT; CAMERA; CERVICAL SPINE; COMPRESSION; DEVICE; DISPOSABLE EQUIPMENT; EDUCATIONAL TECHNOLOGY; EMERGENCY TREATMENT; GUM ELASTIC BOUGIE; INTERMETHOD COMPARISON; INTUBATION; LARYNGOSCOPE; MEDICAL INSTRUMENTATION; MONITOR; ORTHOSIS; PRIORITY JOURNAL; RATING SCALE; RESUSCITATION; SKILL; SPINE STABILIZATION; STAFF TRAINING; THORAX; TRACHEA; VIDEORECORDER; COMPARATIVE STUDY; DEVICES; ELASTICITY; ENDOTRACHEAL INTUBATION; EQUIPMENT DESIGN; EXERCISE; HUMAN; PROCEDURES;

EID: 77954757625     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2010.03.041     Document Type: Article
Times cited : (27)

References (20)
  • 1
    • 33746038008 scopus 로고    scopus 로고
    • Anesthesia for trauma
    • Churchill Livingstone, Philadelphia, Pennsylvania, R.D. Miller (Ed.)
    • Dutton R.P., McCunn M. Anesthesia for trauma. Miller's anesthesia 2005, 2451-2498. Churchill Livingstone, Philadelphia, Pennsylvania. 6th ed. R.D. Miller (Ed.).
    • (2005) Miller's anesthesia , pp. 2451-2498
    • Dutton, R.P.1    McCunn, M.2
  • 2
    • 28544440129 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for Resuscitation 2005
    • European Resuscitation Council
    • European Resuscitation Council European Resuscitation Council Guidelines for Resuscitation 2005. Resuscitation 2005, 67:S1-S189.
    • (2005) Resuscitation , vol.67
  • 5
    • 0029002992 scopus 로고
    • Endotracheal intubation by paramedics during in-hospital CPR
    • Smale J.R., Kutty K., Ohlert J., Cotter T. Endotracheal intubation by paramedics during in-hospital CPR. Chest 1995, 107:1655-1661.
    • (1995) Chest , vol.107 , pp. 1655-1661
    • Smale, J.R.1    Kutty, K.2    Ohlert, J.3    Cotter, T.4
  • 6
    • 38449095332 scopus 로고    scopus 로고
    • The Airway Scope, a new video laryngoscope: its use in three patients with cervical spine problems
    • Liu E.H.C., Poon K.H., Ng B.S.W., Goh E.Y.Y., Goy R.W.L. The Airway Scope, a new video laryngoscope: its use in three patients with cervical spine problems. Br J Anaesth 2008, 100:142-143.
    • (2008) Br J Anaesth , vol.100 , pp. 142-143
    • Liu, E.H.C.1    Poon, K.H.2    Ng, B.S.W.3    Goh, E.Y.Y.4    Goy, R.W.L.5
  • 7
    • 33846207382 scopus 로고    scopus 로고
    • Airway Scope for difficult intubation
    • Asai T., Enomoto Y., Okuda Y. Airway Scope for difficult intubation. Anaesthesia 2007, 62:199.
    • (2007) Anaesthesia , vol.62 , pp. 199
    • Asai, T.1    Enomoto, Y.2    Okuda, Y.3
  • 9
    • 62549116522 scopus 로고    scopus 로고
    • Tracheal intubation using an AirWay Scope in a patient with Halo-Vest Fixation for upper cervical spine injury
    • Maruyama K., Yamada T., Hara K., Nakagawa H., Kitamura A. Tracheal intubation using an AirWay Scope in a patient with Halo-Vest Fixation for upper cervical spine injury. Br J Anaesth 2009, 102:565-566.
    • (2009) Br J Anaesth , vol.102 , pp. 565-566
    • Maruyama, K.1    Yamada, T.2    Hara, K.3    Nakagawa, H.4    Kitamura, A.5
  • 10
    • 43549107680 scopus 로고    scopus 로고
    • ® rigid indirect video laryngoscope: clinical assessment of performance in 320 cases
    • ® rigid indirect video laryngoscope: clinical assessment of performance in 320 cases. Anaesthesia 2008, 63:641-647.
    • (2008) Anaesthesia , vol.63 , pp. 641-647
    • Suzuki, A.1    Toyama, Y.2    Katsumi, N.3
  • 11
    • 58749102601 scopus 로고    scopus 로고
    • Airway scope and StyletScope for tracheal intubation in a simulated difficult airway
    • Komatsu R., Kamata K., Hamada K., Sessler D.I., Ozaki M. Airway scope and StyletScope for tracheal intubation in a simulated difficult airway. Anesth Analg 2009, 108:273-279.
    • (2009) Anesth Analg , vol.108 , pp. 273-279
    • Komatsu, R.1    Kamata, K.2    Hamada, K.3    Sessler, D.I.4    Ozaki, M.5
  • 12
    • 34547891495 scopus 로고    scopus 로고
    • Comparison of the AirWay Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study
    • Koyama Y., Inagawa G., Miyashita T., et al. Comparison of the AirWay Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study. Anaesthesia 2007, 62:936-939.
    • (2007) Anaesthesia , vol.62 , pp. 936-939
    • Koyama, Y.1    Inagawa, G.2    Miyashita, T.3
  • 13
    • 56449095205 scopus 로고    scopus 로고
    • AirWay Scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility
    • Komatsu R., Kamata K., Hoshi I., Sessler D.I., Ozaki M. AirWay Scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility. Br J Anaesth 2008, 101:863-869.
    • (2008) Br J Anaesth , vol.101 , pp. 863-869
    • Komatsu, R.1    Kamata, K.2    Hoshi, I.3    Sessler, D.I.4    Ozaki, M.5
  • 15
    • 0027239954 scopus 로고
    • Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie
    • Nolan J.P., Wilson M.E. Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie. Anaesthesia 1993, 48:630-633.
    • (1993) Anaesthesia , vol.48 , pp. 630-633
    • Nolan, J.P.1    Wilson, M.E.2
  • 16
    • 0029829842 scopus 로고    scopus 로고
    • Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet
    • Gataure P.S., Vaughan R.S., Latto I.P. Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet. Anaesthesia 1996, 51:935-938.
    • (1996) Anaesthesia , vol.51 , pp. 935-938
    • Gataure, P.S.1    Vaughan, R.S.2    Latto, I.P.3
  • 17
    • 0042679497 scopus 로고    scopus 로고
    • Use of the bougie in simulated difficult intubation. 2. Comparison of single-use bougie with multiple-use bougie
    • Marfin A.G., Pandit J.J., Hames K.C., Popat M.T., Yentis S.M. Use of the bougie in simulated difficult intubation. 2. Comparison of single-use bougie with multiple-use bougie. Anaesthesia 2003, 58:852-855.
    • (2003) Anaesthesia , vol.58 , pp. 852-855
    • Marfin, A.G.1    Pandit, J.J.2    Hames, K.C.3    Popat, M.T.4    Yentis, S.M.5
  • 18
    • 33845525230 scopus 로고    scopus 로고
    • A comparison of the use of Trachlight and Eschmann multiple-use introducer in simulated difficult intubation
    • Harvey K., Davies R., Evans A., Latto I.P., Hall J.E. A comparison of the use of Trachlight and Eschmann multiple-use introducer in simulated difficult intubation. Eur J Anaesthesiol 2007, 24:76-81.
    • (2007) Eur J Anaesthesiol , vol.24 , pp. 76-81
    • Harvey, K.1    Davies, R.2    Evans, A.3    Latto, I.P.4    Hall, J.E.5
  • 19
    • 0021701206 scopus 로고
    • Difficult intubation in obstetrics
    • Cormack R.S., Lehane J. Difficult intubation in obstetrics. Anaesthesia 1984, 39:1105-1111.
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 20
    • 33645778801 scopus 로고    scopus 로고
    • ® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy-a manikin study
    • ® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy-a manikin study. Anaesthesia 2006, 61:469-477.
    • (2006) Anaesthesia , vol.61 , pp. 469-477
    • Maharaj, C.H.1    Higgins, B.2    Harte, B.H.3    Laffey, J.G.4