메뉴 건너뛰기




Volumn 102, Issue 4, 2009, Pages 565-566

Tracheal intubation using an AirWay Scope® in a patient with Halo-Vest Fixation for upper cervical spine injury

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ANESTHESIA INDUCTION; CASE REPORT; CERVICAL SPINE INJURY; DETERIORATION; DEVICE; ENDOTRACHEAL INTUBATION; FLUOROSCOPY; GENERAL ANESTHESIA; HALO VEST FIXATION; HUMAN; LETTER; MALE; PRIORITY JOURNAL; SPINE FUSION;

EID: 62549116522     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aep032     Document Type: Letter
Times cited : (7)

References (7)
  • 1
    • 85047696151 scopus 로고    scopus 로고
    • Description and first clinical application of AirWay Scope for tracheal intubation
    • Koyama J, Aoyama T, Kusano Y, et al. Description and first clinical application of AirWay Scope for tracheal intubation. J Neurosurg Anesthesiol 2006; 18: 247-50
    • (2006) J Neurosurg Anesthesiol , vol.18 , pp. 247-250
    • Koyama, J.1    Aoyama, T.2    Kusano, Y.3
  • 2
    • 51849102957 scopus 로고    scopus 로고
    • Randomized crossover comparison of cervical spine motion with use of the AirWay Scope and Macintosh laryngoscope with in-line stabilization: A video-fluoroscopic study
    • Maruyama K, Yamada T, Kawakami R, Hara K. Randomized crossover comparison of cervical spine motion with use of the AirWay Scope and Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study. Br J Anaesth 2008; 101: 563-7
    • (2008) Br J Anaesth , vol.101 , pp. 563-567
    • Maruyama, K.1    Yamada, T.2    Kawakami, R.3    Hara, K.4
  • 3
    • 0041335134 scopus 로고    scopus 로고
    • The halo-vest: Principles of application and management of complications
    • Kang M, Vives MJ, Vaccaro AR. The halo-vest: principles of application and management of complications. J Spinal Cord Med 2003; 26: 186-92
    • (2003) J Spinal Cord Med , vol.26 , pp. 186-192
    • Kang, M.1    Vives, M.J.2    Vaccaro, A.R.3
  • 4
    • 0036599838 scopus 로고    scopus 로고
    • Awake tracheal intubation through the intubating laryngeal mask airway in a patient with halo traction
    • Sener EF, Sarihasan B, Ustun E, Kocamanoglu S, Kelsaka E, Tur A. Awake tracheal intubation through the intubating laryngeal mask airway in a patient with halo traction. Can J Anaesth 2002; 49: 610-3
    • (2002) Can J Anaesth , vol.49 , pp. 610-613
    • Sener, E.F.1    Sarihasan, B.2    Ustun, E.3    Kocamanoglu, S.4    Kelsaka, E.5    Tur, A.6
  • 5
    • 0031597415 scopus 로고    scopus 로고
    • The Combitube® elective anesthetic airway management in a patient with cervical spine fracture
    • Deroy R, Ghoris M. The Combitube® elective anesthetic airway management in a patient with cervical spine fracture. Anesth Analg 1998; 87: 1441-2
    • (1998) Anesth Analg , vol.87 , pp. 1441-1442
    • Deroy, R.1    Ghoris, M.2
  • 6
    • 0031877624 scopus 로고    scopus 로고
    • Emergent airway management at a remote hospital location in a patient wearing halo traction device
    • Corn AI, Lau M, Leonard J. Emergent airway management at a remote hospital location in a patient wearing halo traction device. Anesthesiology 1998; 89: 545-6
    • (1998) Anesthesiology , vol.89 , pp. 545-546
    • Corn, A.I.1    Lau, M.2    Leonard, J.3
  • 7
    • 33845683800 scopus 로고    scopus 로고
    • Retrograde tracheal intubation in a patient with a halo traction device
    • Bhardwaj N, Yaddanapudi S, Makkar S. Retrograde tracheal intubation in a patient with a halo traction device. Anesth Analg 2006; 103: 1628-9
    • (2006) Anesth Analg , vol.103 , pp. 1628-1629
    • Bhardwaj, N.1    Yaddanapudi, S.2    Makkar, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.