메뉴 건너뛰기




Volumn 224, Issue 1, 2010, Pages

Further investigation of a contactless patient-electrode interface of an Electrical Impedance Mammography system

Author keywords

[No Author keywords available]

Indexed keywords

DIAGNOSTIC RADIOGRAPHY; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; ELECTRODES; MAMMOGRAPHY; MEDICAL APPLICATIONS; TOMOGRAPHY;

EID: 77954678239     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/224/1/012166     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 33747829208 scopus 로고    scopus 로고
    • American Cancer Society
    • American Cancer Society 2009 Breast cancer facts & figures p 2009-2010
    • (2009) Breast Cancer Facts & Figures , pp. 2009-2010
  • 3
    • 0006001884 scopus 로고    scopus 로고
    • Preliminary in vitro studies of electrical impedance mammography (EIM): A future technique for non-invasive breast tissue imaging?
    • Tunstall B, Wang W, McCormick M, Walker R and Rew D A 1997 Preliminary in vitro studies of electrical impedance mammography (EIM): a future technique for non-invasive breast tissue imaging? The Breast 6 (4) 253
    • (1997) The Breast , vol.6 , Issue.4 , pp. 253
    • Tunstall, B.1    Wang, W.2    McCormick, M.3    Walker, R.4    Rew, D.A.5
  • 4
    • 0027573139 scopus 로고
    • Finite element modeling of electrode-skin contact impedance in electrical impedance tomography
    • Hua P, Woo E J, Webster J G, Tompkins W J 1993 Finite element modeling of electrode-skin contact impedance in electrical impedance tomography IEEE Trans. Biomedical Eng. 40 (4) 335-343
    • (1993) IEEE Trans. Biomedical Eng. , vol.40 , Issue.4 , pp. 335-343
    • Hua, P.1    Woo, E.J.2    Webster, J.G.3    Tompkins, W.J.4
  • 5
    • 0030250427 scopus 로고    scopus 로고
    • Effect of skin impedance on image quality and variability in electrical impedance tomography: A model study
    • Boone K G and Holder D S 1996 Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study Med. and Biol. Eng. Comput. 34 (5) 351-354
    • (1996) Med. and Biol. Eng. Comput. , vol.34 , Issue.5 , pp. 351-354
    • Boone, K.G.1    Holder, D.S.2
  • 6
    • 0030730753 scopus 로고    scopus 로고
    • Assessment of errors in static electrical impedance tomography with adjacent and trigonometric current patterns
    • Kolehmainen V, Vaukhonen M, Karjalainen P A and Kaipio J P 1997 Assessment of errors in static electrical impedance tomography with adjacent and trigonometric current patterns Physiol. Meas. 18 289-303
    • (1997) Physiol. Meas. , vol.18 , Issue.4 , pp. 289-303
    • Kolehmainen, V.1    Vaukhonen, M.2    Karjalainen, P.A.3    Kaipio, J.P.4
  • 7
    • 70350645563 scopus 로고    scopus 로고
    • Compensation of errors due to discretization, domain truncation and unknown contact impedances in electrical impedance tomography
    • Nissinen A, Heikkinen L M, Kolehmainen V and Kaipio J P 2009 Compensation of errors due to discretization, domain truncation and unknown contact impedances in electrical impedance tomography Meas. Sci. Technol. 20 (10) 13
    • (2009) Meas. Sci. Technol. , vol.20 , Issue.10 , pp. 13
    • Nissinen, A.1    Heikkinen, L.M.2    Kolehmainen, V.3    Kaipio, J.P.4
  • 8
    • 77954670035 scopus 로고    scopus 로고
    • Study into the repeatability of the electrode-skin interface utilizing electrodes commonly used in Electrical Impedance Tomography
    • Wang W et al 2007 Study into the repeatability of the electrode-skin interface utilizing electrodes commonly used in Electrical Impedance Tomography IFMBE Proceedings, ICEBI 2007 17 (10) 336-339
    • (2007) IFMBE Proceedings, ICEBI 2007 , vol.17 , Issue.10 , pp. 336-339
    • Wang, W.1
  • 9
    • 77954674093 scopus 로고    scopus 로고
    • The system performance of Sussex Mk4 EIM Electrical Impedance Mammography (EIM) system for the detection of breast lesions
    • to be published
    • Wang W et al 2010 The system performance of Sussex Mk4 EIM Electrical Impedance Mammography (EIM) system for the detection of breast lesions IFMBE Proceedings, ICEBI 2010 (to be published)
    • (2010) IFMBE Proceedings, ICEBI 2010
    • Wang, W.1
  • 10
    • 0020831476 scopus 로고
    • Imaging spatial distributions of resistivity using applied potential tomography
    • Barber D C and Brown B H 1983 Imaging spatial distributions of resistivity using applied potential tomography IEEE Electron. Lett. 19 (22) 933-935
    • (1983) IEEE Electron. Lett. , vol.19 , Issue.22 , pp. 933-935
    • Barber, D.C.1    Brown, B.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.