메뉴 건너뛰기




Volumn 224, Issue 1, 2010, Pages

In vivo conductivity imaging of canine male pelvis using a 3T MREIT system

Author keywords

canine pelvis; conductivity image; MREIT; prostate

Indexed keywords

CARBON; DISEASES; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE TOMOGRAPHY; MEDICAL APPLICATIONS; SCANNING; UROLOGY;

EID: 77954661601     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/224/1/012020     Document Type: Conference Paper
Times cited : (9)

References (14)
  • 3
    • 0028731158 scopus 로고
    • Impedance tomography using internal current density distribution measured by nuclear magnetic resonance
    • Woo E J, Lee S Y and Mun C W 1994 Impedance tomography using internal current density distribution measured by nuclear magnetic resonance Proc. SPIE 2299 377-85
    • (1994) Proc. SPIE , vol.2299 , pp. 377-385
    • Woo, E.J.1    Lee, S.Y.2    Mun, C.W.3
  • 4
    • 0000872921 scopus 로고    scopus 로고
    • Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT)
    • Ider Y Z and Birgul O 1998 Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT) Elektrik 6 215-25
    • (1998) Elektrik , vol.6 , Issue.3 , pp. 215-225
    • Ider, Y.Z.1    Birgul, O.2
  • 5
    • 0036157954 scopus 로고    scopus 로고
    • Magnetic resonance electrical impedance tomography (MREIT): Simulation study of J-substitution algorithm
    • Kwon O, Woo E J, Yoon J R and Seo J K 2002 Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm IEEE Trans. Biomed. Eng. 49 160-7
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , Issue.2 , pp. 160-167
    • Kwon, O.1    Woo, E.J.2    Yoon, J.R.3    Seo, J.K.4
  • 6
    • 58149302549 scopus 로고    scopus 로고
    • Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
    • Woo E J and Seo J K 2008 Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging Physiol. Meas. 29 R1-R26
    • (2008) Physiol. Meas. , vol.29 , Issue.10
    • Woo, E.J.1    Seo, J.K.2
  • 10
    • 41749109785 scopus 로고    scopus 로고
    • Central zone carcinoma of the prostate gland: A distinct tumor type with poor prognostic features
    • Cohen R J, Shannon B A, Phillips M, Moorin R E, Wheeler T M and Garrett K L 2008 Central zone carcinoma of the prostate gland: a distinct tumor type with poor prognostic features J. Urology 179 1762-7
    • (2008) J. Urology , vol.179 , Issue.5 , pp. 1762-1767
    • Cohen, R.J.1    Shannon, B.A.2    Phillips, M.3    Moorin, R.E.4    Wheeler, T.M.5    Garrett, K.L.6
  • 11
    • 70350517270 scopus 로고    scopus 로고
    • CoReHA: Conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)
    • Jeon K, Kim H J, Lee C O, Woo E J and Seo J K 2009 CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT) J. Biomed. Eng. Res. 30 279-87
    • (2009) J. Biomed. Eng. Res. , vol.30 , pp. 279-287
    • Jeon, K.1    Kim, H.J.2    Lee, C.O.3    Woo, E.J.4    Seo, J.K.5
  • 12
    • 0141894137 scopus 로고    scopus 로고
    • Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography
    • Oh S H, Lee B I, Woo E J, Lee S Y, Cho M H, Kwon O and Seo J K 2003 Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography Phys.Med. Biol. 48 3101-16
    • (2003) Phys.Med. Biol. , vol.48 , Issue.19 , pp. 3101-3116
    • Oh, S.H.1    Lee, B.I.2    Woo, E.J.3    Lee, S.Y.4    Cho, M.H.5    Kwon, O.6    Seo, J.K.7
  • 13
    • 0038644775 scopus 로고    scopus 로고
    • Reconstruction of conductivity and current density images using only one component of magnetic field measurements
    • Seo J K, Yoon J R,Woo E J and Kwon O 2003 Reconstruction of conductivity and current density images using only one component of magnetic field measurements IEEE Trans. Biomed. Eng. 50 1121-4
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.9 , pp. 1121-1124
    • Seo, J.K.1    Yoon, J.R.2    Woo, E.J.3    Kwon, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.