메뉴 건너뛰기




Volumn 15, Issue 3, 2010, Pages

Real-time monitoring of cardiac radio-frequency ablation lesion formation using an optical coherence tomography forward-imaging catheter

Author keywords

Cardiac imaging; Catheter; Optical coherence tomography; Radio frequency ablation

Indexed keywords

CARDIAC ARRHYTHMIA; CARDIAC IMAGING; CIRCULAR SCANNING; DIRECT MEASURES; EX-VIVO; FORWARD-IMAGING; FRAMES PER SECONDS; LEFT VENTRICLES; LESION FORMATION; RADIO-FREQUENCY ABLATION; REAL TIME MONITORING; SCANNING PROBES; SPOT SIZES; TISSUE CONTACT;

EID: 77954597233     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3459134     Document Type: Article
Times cited : (42)

References (15)
  • 2
    • 34247364138 scopus 로고    scopus 로고
    • Utility of intracardiac echocardiography in left heart ablation for tachyarrhythmias
    • J. F. Ren and F. E. Marchinski, "Utility of intracardiac echocardiography in left heart ablation for tachyarrhythmias," Echocardiogr. 24, 533-540 (2007).
    • (2007) Echocardiogr , vol.24 , pp. 533-540
    • Ren, J.F.1    Marchinski, F.E.2
  • 4
    • 76149124852 scopus 로고    scopus 로고
    • In vitro characterization of cardiac radiofrequency ablation lesions using optical coherence tomography
    • C. P. Fleming, K. J. Quan, H. Wang, G. Amit, and A. M. Rollins, "In vitro characterization of cardiac radiofrequency ablation lesions using optical coherence tomography," Opt. Express 18, 3079-3092 (2010).
    • (2010) Opt. Express , vol.18 , pp. 3079-3092
    • Fleming, C.P.1    Quan, K.J.2    Wang, H.3    Amit, G.4    Rollins, A.M.5
  • 6
    • 51649116021 scopus 로고    scopus 로고
    • Quantification of cardiac fiber orientation using optical coherence tomography
    • C. P. Fleming, C. Ripplinger, B. Webb, I. R. Efimov, and A. M. Rollins, "Quantification of cardiac fiber orientation using optical coherence tomography," J. Biomed. Opt. 13, 030505 (2008).
    • (2008) J. Biomed. Opt , vol.13 , pp. 030505
    • Fleming, C.P.1    Ripplinger, C.2    Webb, B.3    Efimov, I.R.4    Rollins, A.M.5
  • 10
    • 33745156132 scopus 로고    scopus 로고
    • Paired-angle-rotation scanning optical coherence tomography forward-imaging probe
    • DOI 10.1364/OL.31.001265
    • J. Wu, M. Conry, C. Gu, F. Wang, Z. Yaqoob, and C. Yang, "Pairedangle- rotation scanning optical coherence tomography forwardimaging probe," Opt. Lett. 31, 1265-1267 (2006). (Pubitemid 43901261)
    • (2006) Optics Letters , vol.31 , Issue.9 , pp. 1265-1267
    • Wu, J.1    Conry, M.2    Gu, C.3    Wang, F.4    Yaqoob, Z.5    Yang, C.6
  • 11
    • 3943113624 scopus 로고    scopus 로고
    • Rapid-Scanning forward-imaging miniature endoscope for real-time optical coherence tomography
    • X. Liu, M. J. Cobb, and Y. Chen, "Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography," Opt. Lett. 29, 1763-1765 (2004).
    • (2004) Opt. Lett , vol.29 , pp. 1763-1765
    • Liu, X.1    Cobb, M.J.2    Chen, Y.3
  • 12
    • 67650080493 scopus 로고    scopus 로고
    • Highresolution OCT balloon imaging catheter with astigmatism correction
    • J. Xi, L. Huo, Y. Wu, M. J. Cobb, J. H. Hwang, and X. Li, "Highresolution OCT balloon imaging catheter with astigmatism correction," Opt. Lett. 34, 1943 (2009).
    • (2009) Opt. Lett , vol.34 , pp. 1943
    • Xi, J.1    Huo, L.2    Wu, Y.3    Cobb, M.J.4    Hwang, J.H.5    Li, X.6
  • 13
    • 5344278287 scopus 로고    scopus 로고
    • Micromotor endoscope catheter for in vivo, ultrahigh resolution optical coherence tomography
    • P. R. Herz, Y. Chen, A. D. Aguirre, K. Schneider, P. Hsiung, and J. G. Fujimoto, "Micromotor endoscope catheter for in vivo, ultrahigh resolution optical coherence tomography," Opt. Lett. 29, 2261-2263 (2004).
    • (2004) Opt. Lett , vol.29 , pp. 2261-2263
    • Herz, P.R.1    Chen, Y.2    Aguirre, A.D.3    Schneider, K.4    Hsiung, P.5    Fujimoto, J.G.6
  • 15
    • 40149109938 scopus 로고    scopus 로고
    • Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometer
    • Z. Hu and A. Rollins, "Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometer," Opt. Lett. 32, 3524-3527 (2007).
    • (2007) Opt. Lett , vol.32 , pp. 3524-3527
    • Hu, Z.1    Rollins, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.