메뉴 건너뛰기




Volumn 15, Issue 26, 2007, Pages 18130-18140

Two-axis magnetically-driven MEMS scanning catheter for endoscopic high-speed optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE ANALYSIS; NATURAL FREQUENCIES; OPTICAL SYSTEMS; OPTICAL TOMOGRAPHY; TISSUE ENGINEERING; VOLTAGE CONTROL;

EID: 37548999839     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.15.018130     Document Type: Article
Times cited : (171)

References (51)
  • 2
    • 0242322532 scopus 로고    scopus 로고
    • Optical coherence tomography for ultrahigh resolution in vivo imaging
    • J. G. Fujimoto, "Optical coherence tomography for ultrahigh resolution in vivo imaging," Nat. Biotechnol. 21, 1361-1367 (2003).
    • (2003) Nat. Biotechnol , vol.21 , pp. 1361-1367
    • Fujimoto, J.G.1
  • 5
    • 0035188381 scopus 로고    scopus 로고
    • Optical coherence tomography in dermatology: A review
    • ://000166541600001
    • J. Welzel, "Optical coherence tomography in dermatology: a review," Skin Research and Technology 7, 19 (2001), ://000166541600001.
    • (2001) Skin Research and Technology , vol.7 , pp. 19
    • Welzel, J.1
  • 6
    • 0035470991 scopus 로고    scopus 로고
    • In vivo burn depth determination by high-speed fiber-based polarization sensitive optical, coherence tomography
    • B. H. Park, C. Saxer, S. M. Srinivas, and J. F. de Boer, "In vivo burn depth determination by high-speed fiber-based polarization sensitive optical, coherence tomography," J. Biomed. Opt. 6, 474-479 (2001).
    • (2001) J. Biomed. Opt , vol.6 , pp. 474-479
    • Park, B.H.1    Saxer, C.2    Srinivas, S.M.3    de Boer, J.F.4
  • 7
    • 4143080657 scopus 로고    scopus 로고
    • Collagen denaturation can be quantified in burned human skin using polarization-sensitive optical coherence tomography
    • M. C. Pierce, R. L. Sheridan, B. H. Park, B. Cense, and J. F. de Boer, "Collagen denaturation can be quantified in burned human skin using polarization-sensitive optical coherence tomography " Burns 30, 511-517 (2004).
    • (2004) Burns , vol.30 , pp. 511-517
    • Pierce, M.C.1    Sheridan, R.L.2    Park, B.H.3    Cense, B.4    de Boer, J.F.5
  • 10
    • 33847260140 scopus 로고    scopus 로고
    • Methods and application areas of endoscopic optical coherence tomography
    • Z. Yaqoob, J. Wu, E. J. McDowell, X. Heng, and C. Yang, "Methods and application areas of endoscopic optical coherence tomography," J. Biomed. Opt. 11, 063001 (2006).
    • (2006) J. Biomed. Opt , vol.11 , pp. 063001
    • Yaqoob, Z.1    Wu, J.2    McDowell, E.J.3    Heng, X.4    Yang, C.5
  • 14
    • 0034072983 scopus 로고    scopus 로고
    • High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography
    • B. E. Bouma, G. J. Tearney, C. C. Compton, and N. S. Nishioka, "High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography," Gastrointest. Endose. 51, 467-474 (2000).
    • (2000) Gastrointest. Endose , vol.51 , pp. 467-474
    • Bouma, B.E.1    Tearney, G.J.2    Compton, C.C.3    Nishioka, N.S.4
  • 19
    • 33746413498 scopus 로고    scopus 로고
    • Optical coherence tomography for imaging the vulnerable plaque
    • G. J. Tearney, I. K. Jang, and B. E. Bouma, "Optical coherence tomography for imaging the vulnerable plaque," J. Biomed. Opt. 11, 021002 (2006).
    • (2006) J. Biomed. Opt , vol.11 , pp. 021002
    • Tearney, G.J.1    Jang, I.K.2    Bouma, B.E.3
  • 26
    • 0032620384 scopus 로고    scopus 로고
    • Power-efficient nonreciprocal interferometer and linear-scanning fiberoptic catheter for optical coherence tomography
    • B. E. Bouma and G. J. Tearney, "Power-efficient nonreciprocal interferometer and linear-scanning fiberoptic catheter for optical coherence tomography," Opt. Lett. 24, 531-533 (1999).
    • (1999) Opt. Lett , vol.24 , pp. 531-533
    • Bouma, B.E.1    Tearney, G.J.2
  • 27
    • 1042302253 scopus 로고    scopus 로고
    • High speed, wide velocity dynamic range Doppler optical coherence tomography (Part. III): In vivo endoscopic imaging of blood flow in the rat and human gastrointestinal tracts
    • V. X. D. Yang, M. L. Gordon, S.-j. Tang, N. E. Marcon, G. Gardiner, B. Qi, S. Bisland, E. Seng-Yue, S. Lo, J. Pekar, B. C. Wilson, and I. A. Vitkin, "High speed, wide velocity dynamic range Doppler optical coherence tomography (Part. III): in vivo endoscopic imaging of blood flow in the rat and human gastrointestinal tracts," Opt. Express 11, 2416-2424 (2003).
    • (2003) Opt. Express , vol.11 , pp. 2416-2424
    • Yang, V.X.D.1    Gordon, M.L.2    Tang, S.-J.3    Marcon, N.E.4    Gardiner, G.5    Qi, B.6    Bisland, S.7    Seng-Yue, E.8    Lo, S.9    Pekar, J.10    Wilson, B.C.11    Vitkin, I.A.12
  • 28
    • 0033313472 scopus 로고    scopus 로고
    • T. Mitsui, Dynamic range of optical reflectometry with spectral interferometry, Japanese Journal of Applied Physics Part 1-Regular Papers Short Notes & Review Papers 38, 6133-6137 (1999), ://000083622000084.
    • T. Mitsui, "Dynamic range of optical reflectometry with spectral interferometry," Japanese Journal of Applied Physics Part 1-Regular Papers Short Notes & Review Papers 38, 6133-6137 (1999), ://000083622000084.
  • 29
    • 0038618462 scopus 로고    scopus 로고
    • Performance of fourier domain vs. time domain optical coherence tomography
    • R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Opt. Express 11, 889-894 (2003).
    • (2003) Opt. Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 30
    • 0242301675 scopus 로고    scopus 로고
    • Improved singla-tonoise ratio in spectral-domain, compared with time-domain optical coherence tomography
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved singla-tonoise ratio in spectral-domain, compared with time-domain optical coherence tomography," Opt. Lett. 28, 2067-2069 (2003).
    • (2003) Opt. Lett , vol.28 , pp. 2067-2069
    • de Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 31
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain, optical coherence tomography
    • M. A. Choma, M. V. Sarunic, C. H. Yang, and J. A. Izatt, "Sensitivity advantage of swept source and Fourier domain, optical coherence tomography," Opt.. Express 11,2183-2189 (2003).
    • (2003) Opt.. Express , vol.11 , pp. 2183-2189
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.H.3    Izatt, J.A.4
  • 32
    • 1542398242 scopus 로고    scopus 로고
    • In vivo human retinal, imaging by ultrahigh-speed spectral domain optical, coherence tomography
    • N. Nassif, B. Cense, B. H. Park, S. H. Yun, T. C. Chen, B. E. Bouma, G. J. Tearney, and J. F. de Boer, "In vivo human retinal, imaging by ultrahigh-speed spectral domain optical, coherence tomography," Opt. Lett. 29,480-482 (2004).
    • (2004) Opt. Lett , vol.29 , pp. 480-482
    • Nassif, N.1    Cense, B.2    Park, B.H.3    Yun, S.H.4    Chen, T.C.5    Bouma, B.E.6    Tearney, G.J.7    de Boer, J.F.8
  • 35
    • 0000063301 scopus 로고    scopus 로고
    • Optical coherence tomography using a frequency-tunable optical source
    • S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, "Optical coherence tomography using a frequency-tunable optical source," Opt. Lett. 22, 340-342 (1997).
    • (1997) Opt. Lett , vol.22 , pp. 340-342
    • Chinn, S.R.1    Swanson, E.A.2    Fujimoto, J.G.3
  • 36
    • 29244445929 scopus 로고    scopus 로고
    • Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source
    • M. A. Choma, K. Hsu, and J. A. Izatt, "Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source," J. Biomed. Opt. 10, 044009 (2005).
    • (2005) J. Biomed. Opt , vol.10 , pp. 044009
    • Choma, M.A.1    Hsu, K.2    Izatt, J.A.3
  • 37
    • 33645820443 scopus 로고    scopus 로고
    • Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography
    • R. Huber, M. Wojtkowski, and J. G. Fujimoto, "Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography," Opt. Express 14, 3225-3237 (2006).
    • (2006) Opt. Express , vol.14 , pp. 3225-3237
    • Huber, R.1    Wojtkowski, M.2    Fujimoto, J.G.3
  • 39
    • 2942568031 scopus 로고    scopus 로고
    • P. H. Tran, D. S. Mukai, M.. Brenner, and Z. Chen, In vivo endoscopic optical, coherence tomography by use of a rotational, microelectroinechanical system probe, Opt. Lett. 29, 1236-1238 (2004).
    • P. H. Tran, D. S. Mukai, M.. Brenner, and Z. Chen, "In vivo endoscopic optical, coherence tomography by use of a rotational, microelectroinechanical system probe," Opt. Lett. 29, 1236-1238 (2004).
  • 41
    • 3943113624 scopus 로고    scopus 로고
    • Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography
    • X. Liu, M. J. Cobb, Y. Chen, M. B. Kimmey, and X. Li, "Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography," Opt. Lett. 29, 1763-1765 (2004).
    • (2004) Opt. Lett , vol.29 , pp. 1763-1765
    • Liu, X.1    Cobb, M.J.2    Chen, Y.3    Kimmey, M.B.4    Li, X.5
  • 42
    • 0001352717 scopus 로고    scopus 로고
    • Endoscopic optical, coherence tomography based on a microelectromechanical mirror
    • Y. T. Pan, H. K. Xie, and G. K. Fedder, "Endoscopic optical, coherence tomography based on a microelectromechanical mirror," Opt. Lett. 26 1966-1968 (2001).
    • (2001) Opt. Lett , vol.26 , pp. 1966-1968
    • Pan, Y.T.1    Xie, H.K.2    Fedder, G.K.3
  • 43
    • 4344565790 scopus 로고    scopus 로고
    • A two-axis electrothermal micromirror for endoscopic optical coherence tomography
    • A. Jain, A. Kopa, Y. T. Pan, G. K. Fedder, and H. K. Xie, "A two-axis electrothermal micromirror for endoscopic optical coherence tomography," IEEE J. Sel. Top. Quantum Electron. 10, 636-642 (2004).
    • (2004) IEEE J. Sel. Top. Quantum Electron , vol.10 , pp. 636-642
    • Jain, A.1    Kopa, A.2    Pan, Y.T.3    Fedder, G.K.4    Xie, H.K.5
  • 44
    • 33646204898 scopus 로고    scopus 로고
    • Three-dimensional endoscopic optical coherence tomography by use of a two-axis microelectromechanical scanning mirror
    • W. Jung, D. T. McCormick, J. Zhang, L. Wang, N. C. Tien, and Z. Chen, "Three-dimensional endoscopic optical coherence tomography by use of a two-axis microelectromechanical scanning mirror," Appl. Phys. Lett. 88, 163901 (2006).
    • (2006) Appl. Phys. Lett , vol.88 , pp. 163901
    • Jung, W.1    McCormick, D.T.2    Zhang, J.3    Wang, L.4    Tien, N.C.5    Chen, Z.6
  • 46
    • 33847743797 scopus 로고    scopus 로고
    • Two-axis MEMS scanning catheter for ultrahigh resolution three-dimensional and en face Imaging
    • A. D. Aguirre, P. R. Hertz, Y. Chen, J. G. Fujimoto, W. Piyawattanametha, L. Fan, and M. C. Wu, "Two-axis MEMS scanning catheter for ultrahigh resolution three-dimensional and en face Imaging," Opt. Express 15, 2445-2453 (2007).
    • (2007) Opt. Express , vol.15 , pp. 2445-2453
    • Aguirre, A.D.1    Hertz, P.R.2    Chen, Y.3    Fujimoto, J.G.4    Piyawattanametha, W.5    Fan, L.6    Wu, M.C.7
  • 48
    • 33846077552 scopus 로고    scopus 로고
    • Polyimide amplified piezoelectric scanning mirror for spectral domain, optical, coherence tomography
    • J. M. Zara, and P. E. Patterson, "Polyimide amplified piezoelectric scanning mirror for spectral domain, optical, coherence tomography," Appl. Phys. Lett. 89, 263901 (2006).
    • (2006) Appl. Phys. Lett , vol.89 , pp. 263901
    • Zara, J.M.1    Patterson, P.E.2
  • 49
    • 33750583313 scopus 로고    scopus 로고
    • A 2-axis optical scanner driven nonresonantly by electromagnetic force for OCT imaging
    • T. Mitsui, Y. Takahashi, and Y. Watanabe, "A 2-axis optical scanner driven nonresonantly by electromagnetic force for OCT imaging," J. Micromech. Microeng. 16, 2482-2487 (2006).
    • (2006) J. Micromech. Microeng , vol.16 , pp. 2482-2487
    • Mitsui, T.1    Takahashi, Y.2    Watanabe, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.