메뉴 건너뛰기




Volumn 14, Issue 4, 2010, Pages 1098-1105

A real-time and self-calibrating algorithm based on triaxial accelerometer signals for the detection of human posture and activity

Author keywords

Activity and posture monitoring; real time movement classification; triaxial accelerometer; wearable device

Indexed keywords

CLASSIFICATION QUALITY; COMPUTATIONAL RESOURCES; FUNCTIONAL ABILITIES; HARSH ENVIRONMENT; HUMAN ACTIVITIES; HUMAN POSTURES; NOVEL TASK; REALTIME PROCESSING; REMOTE SURVEILLANCE; SELF-CALIBRATING; SENSOR ORIENTATION; STATIC AND DYNAMIC; TECHNOLOGICAL ADVANCES; TRIAXIAL ACCELEROMETER; WEARABLE DEVICES;

EID: 77954591953     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/TITB.2010.2050696     Document Type: Article
Times cited : (92)

References (33)
  • 1
    • 0141499236 scopus 로고    scopus 로고
    • Enhancing the quality of life through wearable technology
    • May/Jun.
    • S. Park and S. Jayaraman, "Enhancing the quality of life through wearable technology," IEEE Eng. Med. Biol. Mag., vol.22, no.3, pp. 41-48, May/Jun. 2003.
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , Issue.3 , pp. 41-48
    • Park, S.1    Jayaraman, S.2
  • 2
    • 28044467315 scopus 로고    scopus 로고
    • The technology of accelerometry-based activity monitors: Current and future
    • K. Y. Chen and D. R. Bassett, "The technology of accelerometry-based activity monitors: Current and future," Med. Sci. Sports Exerc., vol.37, no.11, pp. S490-S500, 2005.
    • (2005) Med. Sci. Sports Exerc. , vol.37 , Issue.11
    • Chen, K.Y.1    Bassett, D.R.2
  • 3
    • 33947258964 scopus 로고    scopus 로고
    • Clinical application of sensors for human posture andmovement analysis:Areview
    • W. Y. Wong, M. S. Wong, and K. H. Lo, "Clinical application of sensors for human posture andmovement analysis:Areview," Prosthet. Orthotics Int., vol.31, no.1, pp. 62-75, 2007.
    • (2007) Prosthet. Orthotics Int. , vol.31 , Issue.1 , pp. 62-75
    • Wong, W.Y.1    Wong, M.S.2    Lo, K.H.3
  • 4
    • 0031986156 scopus 로고    scopus 로고
    • An accelerometry based system for the assessment of balance and postural sway
    • G.Kamen,C. Patten,C.Du, and S. Sison, "An accelerometry based system for the assessment of balance and postural sway," Gerontology, vol.44, pp. 40-45, 1998.
    • (1998) Gerontology , vol.44 , pp. 40-45
    • Kamen, G.1    Patten, C.2    Du, C.3    Sison, S.4
  • 5
    • 0033060589 scopus 로고    scopus 로고
    • Physical activity monitoring based on accelerometry: Validation and comparison with video observation
    • K. Aminian, P. Robert, E. E. Buchser, B. Rutschmann, D. Hayoz, and M. Depairon, "Physical activity monitoring based on accelerometry: Validation and comparison with video observation," Med. Biol. Eng. Comput., vol.37, pp. 304-308, 1999.
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 304-308
    • Aminian, K.1    Robert, P.2    Buchser, E.E.3    Rutschmann, B.4    Hayoz, D.5    Depairon, M.6
  • 6
    • 0031106807 scopus 로고    scopus 로고
    • A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    • Mar.
    • C. V. C. Bouten, K. T. M. Koekkoek, M. Verduin, R. Kodde, and J. D. Janssen, "A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity," IEEE Trans. Biomed. Eng., vol.44, no.3, pp. 136-147, Mar. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , Issue.3 , pp. 136-147
    • Bouten, C.V.C.1    Koekkoek, K.T.M.2    Verduin, M.3    Kodde, R.4    Janssen, J.D.5
  • 7
    • 1542723606 scopus 로고    scopus 로고
    • Inclination measurement of human movement using a 3-D accelerometer with autocalibration
    • Mar.
    • H. J. Luinge and P. H. Veltink, "Inclination measurement of human movement using a 3-D accelerometer with autocalibration," IEEE Trans.Neural Syst. Rehabil. Eng., vol.12, no.1, pp. 112-121, Mar. 2004.
    • (2004) IEEE Trans.Neural Syst. Rehabil. Eng. , vol.12 , Issue.1 , pp. 112-121
    • Luinge, H.J.1    Veltink, P.H.2
  • 8
    • 6344237275 scopus 로고    scopus 로고
    • Classification of basic daily movements using a triaxial accelerometer
    • M. J.Mathie, A. C. F. Coster,B.G.Celler, and N. H. Lovell, "Classification of basic daily movements using a triaxial accelerometer," Med. Biol. Eng. Comput., vol.42, pp. 670-687, 2004.
    • (2004) Med. Biol. Eng. Comput. , vol.42 , pp. 670-687
    • Mathie, M.J.1    Coster, A.C.F.2    Celler, B.G.3    Lovell, N.H.4
  • 9
    • 2342539792 scopus 로고    scopus 로고
    • Accelerometry: Providing an integrated practical method for long-term, ambulatory monitoring of human movement
    • M. J.Mathie, A. C. F. Coster, N. H. Lovell, and B. G. Celler, "Accelerometry: Providing an integrated practical method for long-term, ambulatory monitoring of human movement," Physiol. Meas., vol.25, pp. R1-R20, 2004.
    • (2004) Physiol. Meas. , vol.25
    • Mathie, M.J.1    Coster, A.C.F.2    Lovell, N.H.3    Celler, B.G.4
  • 10
    • 30744436064 scopus 로고    scopus 로고
    • Implementation of a real-time human activity classifier using a triaxial accelerometer for ambulatory monitoring
    • Jan.
    • D. M. Karantonis, M. R. Narayanan, M. Mathie, N. H. Lovell, and B. G. Celler, "Implementation of a real-time human activity classifier using a triaxial accelerometer for ambulatory monitoring," IEEE Trans. Inf. Technol. Biomed., vol.10, no.1, pp. 156-167, Jan. 2006.
    • (2006) IEEE Trans. Inf. Technol. Biomed. , vol.10 , Issue.1 , pp. 156-167
    • Karantonis, D.M.1    Narayanan, M.R.2    Mathie, M.3    Lovell, N.H.4    Celler, B.G.5
  • 11
    • 0030725217 scopus 로고    scopus 로고
    • Computerized analysis of daily life monitor activity for ambulatory monitoring
    • K. Kiani, C. J. Snijders, and E. S. Gelsema, "Computerized analysis of daily life monitor activity for ambulatory monitoring," Technol. Health Care, vol.5, pp. 307-318, 1997.
    • (1997) Technol. Health Care , vol.5 , pp. 307-318
    • Kiani, K.1    Snijders, C.J.2    Gelsema, E.S.3
  • 12
    • 0141722629 scopus 로고    scopus 로고
    • Wearable sensors and telerehabilitation
    • Jun.
    • J. M. Winters, Y. Wang, and J. M. Winters, "Wearable sensors and telerehabilitation," IEEE Eng. Med. Biol. Mag., vol.22, no.3, pp. 56-65, Jun. 2003.
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , Issue.3 , pp. 56-65
    • Winters, J.M.1    Wang, Y.2    Winters, J.M.3
  • 13
    • 38149112664 scopus 로고    scopus 로고
    • Activity recognition using one triaxial accelerometer: A neuro fuzzy classifier with feature reduction
    • J. Y. Yang, Y. P. Chen, G. Y. Lee, S. N. Liou, and J. S. Wang, "Activity recognition using one triaxial accelerometer: A neuro fuzzy classifier with feature reduction," in Proc. ICEC, vol.4740, pp. 395-400, 2007.
    • (2007) Proc. ICEC , vol.4740 , pp. 395-400
    • Yang, J.Y.1    Chen, Y.P.2    Lee, G.Y.3    Liou, S.N.4    Wang, J.S.5
  • 14
    • 45149106299 scopus 로고    scopus 로고
    • Smart garment for trunk posture monitoring: A preliminary study
    • W.Y.Wong andM. S.Wong, "Smart garment for trunk posture monitoring: A preliminary study," Scoliosis, vol.3:7, 2008.
    • (2008) Scoliosis , vol.3 , pp. 7
    • Wong, W.Y.1    Wong, M.S.2
  • 16
    • 77954577073 scopus 로고    scopus 로고
    • Weightlessness feature-A novel feature for single tri-axial accelerometer based activity recognition
    • Z. He, Z. Liu, L. Jin, L. Zhen, and J. Huang, "Weightlessness feature-A novel feature for single tri-axial accelerometer based activity recognition," in Proc. Int. Conf. Pattern Recognit., 2008, pp. 1-4.
    • (2008) Proc. Int. Conf. Pattern Recognit. , pp. 1-4
    • He, Z.1    Liu, Z.2    Jin, L.3    Zhen, L.4    Huang, J.5
  • 17
    • 34249776689 scopus 로고    scopus 로고
    • Advanced wearable health systems and applications research and development efforts in the european union
    • May/Jun.
    • A. Lymberis and A. Dittmar, "Advanced wearable health systems and applications research and development efforts in the european union," IEEE Eng. Med. Biol. Mag., vol.26, no.3, pp. 29-33, May/Jun. 2007.
    • (2007) IEEE Eng. Med. Biol. Mag. , vol.26 , Issue.3 , pp. 29-33
    • Lymberis, A.1    Dittmar, A.2
  • 18
    • 77954573122 scopus 로고    scopus 로고
    • [Online]. Available:
    • WearIt@Work EU IP. [Online]. Available: http://www.wearitatwork.com
    • WearIt@Work EU IP
  • 19
    • 77954603385 scopus 로고    scopus 로고
    • [Online]. Available:
    • ProeTEX EU IP. [Online]. Available: http://www.proetex.org
    • ProeTEX EU IP
  • 21
    • 35048842427 scopus 로고    scopus 로고
    • Activity recognition from user-annotated acceleration data
    • L. Bao and S. S. Intille, "Activity recognition from user-annotated acceleration data," in Proc. PERVASIVE, 2004, pp. 1-17.
    • (2004) Proc. PERVASIVE , pp. 1-17
    • Bao, L.1    Intille, S.S.2
  • 25
    • 35048903707 scopus 로고    scopus 로고
    • Automatic calibration of body worn acceleration sensors
    • NewYork: Springer-Verlag
    • P. Lukowicz, H. Junker, and G. Tröster, "Automatic calibration of body worn acceleration sensors," in Pervasive Computing. NewYork: Springer-Verlag, 2004, pp. 176-181.
    • (2004) Pervasive Computing , pp. 176-181
    • Lukowicz, P.1    Junker, H.2    Tröster, G.3
  • 28
    • 0021910514 scopus 로고
    • The frequency content of gait
    • E. K. Antonsson and R. W. Mann, "The frequency content of gait," J. Biomech., vol.18, no.1, pp. 39-47, 1985.
    • (1985) J. Biomech. , vol.18 , Issue.1 , pp. 39-47
    • Antonsson, E.K.1    Mann, R.W.2
  • 29
    • 52149092517 scopus 로고    scopus 로고
    • Automatic selfcalibration of body worn triaxial-accelerometers for application in healthcare
    • Jul.
    • M. Gietzelt, K. H. Wolf, M. Marschollek, and R. Haux, "Automatic selfcalibration of body worn triaxial-accelerometers for application in healthcare," in Proc. Pervasive Health, Jul., 2008, pp. 177-180.
    • (2008) Proc. Pervasive Health , pp. 177-180
    • Gietzelt, M.1    Wolf, K.H.2    Marschollek, M.3    Haux, R.4
  • 31
    • 0034039075 scopus 로고    scopus 로고
    • Quantitating physical activity in COPD using a triaxial accelerometer
    • B. G. Steele, L. Holt, B. Belza, S. M. Ferris, S. Lakshminaryan, and D. M. Buchner, "Quantitating physical activity in COPD using a triaxial accelerometer," Chest, vol.117, pp. 1359-1367, 2000.
    • (2000) Chest , vol.117 , pp. 1359-1367
    • Steele, B.G.1    Holt, L.2    Belza, B.3    Ferris, S.M.4    Lakshminaryan, S.5    Buchner, D.M.6
  • 32
    • 77950188777 scopus 로고    scopus 로고
    • Automatic feature selection for context recognition in mobile devices
    • V.Kononen, J. Mantyjarvi,H. Simila, J. Parkka, and M. Ermes, "Automatic feature selection for context recognition in mobile devices," Pervasive Mobile Comput., vol.6, no.2, pp. 181-197, 2010.
    • (2010) Pervasive Mobile Comput , vol.6 , Issue.2 , pp. 181-197
    • Kononen, V.1    Mantyjarvi, J.2    Simila, H.3    Parkka, J.4    Ermes, M.5
  • 33
    • 39449090035 scopus 로고    scopus 로고
    • Detection of daily activities and sports with wearable sensors in controlled and uncontrolled conditions
    • Jan.
    • M. Ermes, J. Parkka, J. Mantyjarvi, and I. Korhonen, "Detection of daily activities and sports with wearable sensors in controlled and uncontrolled conditions," IEEE Trans. Inf. Technol. Biomed., vol.12, no.1, pp. 20-26, Jan. 2008.
    • (2008) IEEE Trans. Inf. Technol. Biomed. , vol.12 , Issue.1 , pp. 20-26
    • Ermes, M.1    Parkka, J.2    Mantyjarvi, J.3    Korhonen, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.