메뉴 건너뛰기




Volumn , Issue , 2007, Pages 837-844

Classification of posture and movement using a 3-axis accelerometer

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC POWER TRANSMISSION; ERROR CORRECTION; INFORMATION TECHNOLOGY; SENSOR NETWORKS; SENSORS; TECHNOLOGY;

EID: 49049096121     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICCIT.2007.4420364     Document Type: Conference Paper
Times cited : (35)

References (12)
  • 1
    • 0141499236 scopus 로고    scopus 로고
    • Park s, Jayaraman S, Enhancing the Quality of Life Through Wearable Technology, IEEE Eng. Med. Biol. Mag., 22, no 3, pp. 41-48, 2003.
    • Park s, Jayaraman S, "Enhancing the Quality of Life Through Wearable Technology", IEEE Eng. Med. Biol. Mag., vol. 22, no 3, pp. 41-48, 2003.
  • 2
    • 0031106807 scopus 로고    scopus 로고
    • A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    • Mar
    • C.V. Bouten,K. T.Koekkoek, M.Verduin, R.Kodde, and J. D. Janssen, "A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity," IEEE Trans. Biomed. Eng., vol. 44, no. 3, pp. 136-147, Mar. 1997.
    • (1997) IEEE Trans. Biomed. Eng , vol.44 , Issue.3 , pp. 136-147
    • Bouten, C.V.1    Koekkoek, K.T.2    Verduin, M.3    Kodde, R.4    Janssen, J.D.5
  • 3
    • 3142592496 scopus 로고    scopus 로고
    • A pilot study of long term monitoring of human movements in the home using accelerometry
    • M. J. Mathie, A. C. F. Coster, N. H. Lovell, and B. G. Celler, "A pilot study of long term monitoring of human movements in the home using accelerometry," J. Telemed. Telecare, vol. 10, pp. 144-151, 2004.
    • (2004) J. Telemed. Telecare , vol.10 , pp. 144-151
    • Mathie, M.J.1    Coster, A.C.F.2    Lovell, N.H.3    Celler, B.G.4
  • 4
    • 0033060589 scopus 로고    scopus 로고
    • Physical activity monitoring based on Accelerometry: Validation and comparison with video observation
    • K. Aminian, P. Robert, E. E. Buchser, B. Rutschmann, D. Hayoz, and M. Depairon, "Physical activity monitoring based on Accelerometry: Validation and comparison with video observation," Med. Biol. Eng. Comput., vol. 37, pp. 304-308, 1999.
    • (1999) Med. Biol. Eng. Comput , vol.37 , pp. 304-308
    • Aminian, K.1    Robert, P.2    Buchser, E.E.3    Rutschmann, B.4    Hayoz, D.5    Depairon, M.6
  • 5
    • 0141722629 scopus 로고    scopus 로고
    • Wearable sensors and telerehabilitation
    • J. M. Winters, Y. Wang, and J. M. Winters, "Wearable sensors and telerehabilitation," IEEE Eng. Med. Biol. Mag., vol. 22, no. 3, pp. 56-65, 2003.
    • (2003) IEEE Eng. Med. Biol. Mag , vol.22 , Issue.3 , pp. 56-65
    • Winters, J.M.1    Wang, Y.2    Winters, J.M.3
  • 6
    • 30744436064 scopus 로고    scopus 로고
    • Implementation of a Real-Time Human Movement Classifier Using a Triaxial Accelerometer for Ambulatory Monitoring
    • Jan
    • Dean M. Karantonis, Michael R. Narayanan, Merryn Mathie, Nigel H. Lovell, and Branko G. Celler, "Implementation of a Real-Time Human Movement Classifier Using a Triaxial Accelerometer for Ambulatory Monitoring", IEEE Trans. Information Technology in Biomedicine, vol. 10, no. 1, pp. 156-167, Jan. 2006.
    • (2006) IEEE Trans. Information Technology in Biomedicine , vol.10 , Issue.1 , pp. 156-167
    • Karantonis, D.M.1    Narayanan, M.R.2    Mathie, M.3    Lovell, N.H.4    Celler, B.G.5
  • 7
    • 49049094332 scopus 로고    scopus 로고
    • A Disign of algorithm for Analysis Acitive Using 3-Axis Accelerometer
    • Seung-Hyung Lee, Ye-Teak Lim, Kyung-Joung Lee "A Disign of algorithm for Analysis Acitive Using 3-Axis Accelerometer", J. of KIEE, vol. 53, no. 5. 2004.
    • (2004) J. of KIEE , vol.53 , Issue.5
    • Lee, S.-H.1    Lim, Y.-T.2    Lee, K.-J.3
  • 8
    • 3142592496 scopus 로고    scopus 로고
    • A pilot study of long term monitoring of human movement in the home using accelerometry
    • M. J. Mathie, A. C. F. Coster, N. H. Lovell, and B. G. Celler., "A pilot study of long term monitoring of human movement in the home using accelerometry", J. Telemed, Telecare, vol. 10, pp. 144-151, 2004.
    • (2004) J. Telemed, Telecare , vol.10 , pp. 144-151
    • Mathie, M.J.1    Coster, A.C.F.2    Lovell, N.H.3    Celler, B.G.4
  • 10
    • 0037599299 scopus 로고    scopus 로고
    • Ambulatory System for Human Motion Analysis Using a Kinematic Sensor: Monitoring fo Daily Physical Activity in the Elderly
    • Najafi, B., Aminian, K., Paraschiv-Ionescu, A., Loew, F., Büla, C. J., Robert, P., "Ambulatory System for Human Motion Analysis Using a Kinematic Sensor: Monitoring fo Daily Physical Activity in the Elderly", IEEE Trans Biomed Eng, vol.50, no.6, 2003.
    • (2003) IEEE Trans Biomed Eng , vol.50 , Issue.6
    • Najafi, B.1    Aminian, K.2    Paraschiv-Ionescu, A.3    Loew, F.4    Büla, C.J.5    Robert, P.6
  • 11
    • 49049087055 scopus 로고    scopus 로고
    • http://www.maxfor.co.kr/maxfor/gnu3/images/ TIP7xx. Series.Manual_ver1.2. pdf..
  • 12
    • 6344237275 scopus 로고    scopus 로고
    • Classification of basic daily movements using a triaxial accelerometer
    • M. J. Mathie, A. C. F. Coster,B.G.Celler, and N. H. Lovell, " Classification of basic daily movements using a triaxial accelerometer", Med. Biol. Eng. Comput., vol. 42, pp. 670-687, 2004.
    • (2004) Med. Biol. Eng. Comput , vol.42 , pp. 670-687
    • Mathie, M.J.1    Coster, A.C.F.2    Celler, B.G.3    Lovell, N.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.