메뉴 건너뛰기




Volumn 10, Issue 6, 2010, Pages 976-980

Aortic root distensibility and cross-sectional areas in stented and subcoronary stentless bioprostheses in pigs

Author keywords

Aortic valve replacement; Heart valve bioprostheses; Heart valve stentless; Magnetic resonance imaging

Indexed keywords

ANIMAL EXPERIMENT; AORTA ROOT; AORTA VALVE REPLACEMENT; ARTERY COMPLIANCE; ARTICLE; BIOLOGICAL MODEL; BIOPROSTHESIS; CLINICAL EVALUATION; CONTROLLED STUDY; CORONARY STENT; EQUIPMENT DESIGN; FUNCTIONAL ASSESSMENT; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART VENTRICLE ENDDIASTOLIC PRESSURE; INTERMETHOD COMPARISON; MATERIALS TESTING; MORTALITY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SUTURING METHOD; SWINE;

EID: 77954550835     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2009.230771     Document Type: Article
Times cited : (9)

References (15)
  • 2
    • 0033765958 scopus 로고    scopus 로고
    • Loss of sinus compliance, cause of degenerative aortic valve disease, and early failure of biological valves
    • Robicsek F, Thubrikar M. Loss of sinus compliance, cause of degenerative aortic valve disease, and early failure of biological valves. Z Kardiol 2000;89:104-106.
    • (2000) Z Kardiol , vol.89 , pp. 104-106
    • Robicsek, F.1    Thubrikar, M.2
  • 3
    • 31844440684 scopus 로고    scopus 로고
    • Impact of mechanical and biological aortic valve replacement on coronary perfusion: A prospective, randomized study
    • Bakhtiary F, Abolmaali N, Dzemali O, Wittlinger T, Doss M, Moritz A, Kleine P. Impact of mechanical and biological aortic valve replacement on coronary perfusion: a prospective, randomized study. J Heart Valve Dis 2006;15:5-11.
    • (2006) J Heart Valve Dis , vol.15 , pp. 5-11
    • Bakhtiary, F.1    Abolmaali, N.2    Dzemali, O.3    Wittlinger, T.4    Doss, M.5    Moritz, A.6    Kleine, P.7
  • 4
    • 26844501573 scopus 로고    scopus 로고
    • Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: A large retrospective study
    • Borger AAA, Carson SM, Ivanov J, Rao V, Scully HE, Feindel CM, David TE. Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study. Ann Thorac Surg 2005;80:2180-2185.
    • (2005) Ann Thorac Surg , vol.80 , pp. 2180-2185
    • Borger, A.A.A.1    Carson, S.M.2    Ivanov, J.3    Rao, V.4    Scully, H.E.5    Feindel, C.M.6    David, T.E.7
  • 6
    • 0043128908 scopus 로고    scopus 로고
    • Aortic distensibility after aortic root replacement assessed with cardiovascular magnetic resonance
    • Melina G, Rajappan K, Amrani M, Khaghani A, Pennell DJ, Yacoub MH. Aortic distensibility after aortic root replacement assessed with cardiovascular magnetic resonance. J Heart Valve Dis 2002; 11:67-74.
    • (2002) J Heart Valve Dis , vol.11 , pp. 67-74
    • Melina, G.1    Rajappan, K.2    Amrani, M.3    Khaghani, A.4    Pennell, D.J.5    Yacoub, M.H.6
  • 7
    • 0032882007 scopus 로고    scopus 로고
    • Role of sinus wall compliance in aortic leaflet function
    • Robicsek F, Thubrikar M. Role of sinus wall compliance in aortic leaflet function. Am J Cardiol 1999;84:944-946.
    • (1999) Am J Cardiol , vol.84 , pp. 944-946
    • Robicsek, F.1    Thubrikar, M.2
  • 8
    • 0037402766 scopus 로고    scopus 로고
    • A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve
    • De Hart J, Baaijens FP, Peters GW, Schreurs PJ. A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve. J Biomech 2003;36:699-712.
    • (2003) J Biomech , vol.36 , pp. 699-712
    • de Hart, J.1    Baaijens, F.P.2    Peters, G.W.3    Schreurs, P.J.4
  • 9
    • 0027715526 scopus 로고
    • The value of the stentless biovalve prosthesis. An experimental study
    • Hazekamp MG, Goffin YA, Huysmans HA. The value of the stentless biovalve prosthesis. An experimental study. Eur J Cardiothorac Surg 1993;7:514-519.
    • (1993) Eur J Cardiothorac Surg , vol.7 , pp. 514-519
    • Hazekamp, M.G.1    Goffin, Y.A.2    Huysmans, H.A.3
  • 11
    • 33746635455 scopus 로고    scopus 로고
    • Is the degeneration of aortic valve bioprostheses similar to that of native aortic valves? Insights into valvular pathology
    • Skowasch D, Steinmetz M, Nickenig G, Bauriedel G. Is the degeneration of aortic valve bioprostheses similar to that of native aortic valves? Insights into valvular pathology. Expert Rev Medical Devices 2006; 3:453-462.
    • (2006) Expert Rev Medical Devices , vol.3 , pp. 453-462
    • Skowasch, D.1    Steinmetz, M.2    Nickenig, G.3    Bauriedel, G.4
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.