메뉴 건너뛰기




Volumn 39, Issue 7, 2010, Pages 687-692

Filler materials for augmentation of osteoporotic vertebral fractures;Füllmaterialien zur Augmentation von osteoporotischen Wirbelkörperfrakturen

Author keywords

Calcium phosphate cement; Kyphoplasty; Polymethylmethacrylate; Vertebral compression fracture; Vertebroplasty

Indexed keywords

ARTICLE; BONE PROSTHESIS; EQUIPMENT DESIGN; HUMAN; METHODOLOGY; OSTEOPOROSIS; OSTEOSYNTHESIS; PERCUTANEOUS VERTEBROPLASTY; PLACEBO EFFECT; SPINE FRACTURE; TREATMENT OUTCOME;

EID: 77954457435     PISSN: 00854530     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00132-010-1619-z     Document Type: Article
Times cited : (4)

References (37)
  • 1
    • 0000671221 scopus 로고
    • Effects of polysaccharides on the cement properties in the cement monocalcium phosphate/β-tricalcium phosphate system
    • Andrianjatovo H, Lemaître L (1995) Effects of polysaccharides on the cement properties in the cement monocalcium phosphate/β-tricalcium phosphate system. Innov Tech Biol Med 16(1):140-147
    • (1995) Innov Tech Biol Med , vol.16 , Issue.1 , pp. 140-147
    • Andrianjatovo, H.1    Lemaître, L.2
  • 2
    • 0032810055 scopus 로고    scopus 로고
    • The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
    • Bai B, Jazrawi LM, Kummer FJ, Spivak JM (1999) The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine 15:1521-1526
    • (1999) Spine , vol.15 , pp. 1521-1526
    • Bai, B.1    Jazrawi, L.M.2    Kummer, F.J.3    Spivak, J.M.4
  • 3
    • 0035879117 scopus 로고    scopus 로고
    • The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior
    • Belkoff SM, Mathis JM, Jasper LE et al (2001) The biomechanics of vertebroplasty: the effect of cement volume on mechanical behavior. Spine 26:1537-1541
    • (2001) Spine , vol.26 , pp. 1537-1541
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3
  • 4
    • 0038638437 scopus 로고    scopus 로고
    • Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
    • Belkoff SM, Molloy S (2003) Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine 28:1555-1559
    • (2003) Spine , vol.28 , pp. 1555-1559
    • Belkoff, S.M.1    Molloy, S.2
  • 5
    • 0036328899 scopus 로고    scopus 로고
    • Adjacent vertebral failure after vertebroplasty, a biomechanical investigation
    • Berlemann U, Ferguson SJ, Nolte LP, Heini PF (2002) Adjacent vertebral failure after vertebroplasty, a biomechanical investigation. J Bone Joint Surg Br 84:748-752
    • (2002) J Bone Joint Surg Br , vol.84 , pp. 748-752
    • Berlemann, U.1    Ferguson, S.J.2    Nolte, L.P.3    Heini, P.F.4
  • 6
    • 64049086001 scopus 로고    scopus 로고
    • Suitibility of a calcium phosphate cement in osteoporotic vertebral body fracture augmentation, a controlled randomized clinical trial of balloon kyphoplasty comparing calcium phosphate versus polymethylmethacrylate
    • Blattert TR, Jestaedt L, Weckbach A (2009) Suitibility of a calcium phosphate cement in osteoporotic vertebral body fracture augmentation, a controlled randomized clinical trial of balloon kyphoplasty comparing calcium phosphate versus polymethylmethacrylate. Spine 34:108-114
    • (2009) Spine , vol.34 , pp. 108-114
    • Blattert, T.R.1    Jestaedt, L.2    Weckbach, A.3
  • 7
    • 37249083516 scopus 로고    scopus 로고
    • Adjacent vertebral failure after vertebroplasty: A biomechanical study of low modulus PMMA cement
    • Boger A, Heini P, Windolf M, Schneider E (2007) Adjacent vertebral failure after vertebroplasty: a biomechanical study of low modulus PMMA cement. Eur Spine J 16(12):2118-2125
    • (2007) Eur Spine J , vol.16 , Issue.12 , pp. 2118-2125
    • Boger, A.1    Heini, P.2    Windolf, M.3    Schneider, E.4
  • 8
    • 40849094273 scopus 로고    scopus 로고
    • Comparison of an experimental bone cement with surgical Simplex® P, Spineplex® and Cortoss®
    • Boyd D, Towler MR, Wren A, Clarkin OM (2008) Comparison of an experimental bone cement with surgical Simplex® P, Spineplex® and Cortoss® . J Mater Sci Mater Med 19:1745-1752
    • (2008) J Mater Sci Mater Med , vol.19 , pp. 1745-1752
    • Boyd, D.1    Towler, M.R.2    Wren, A.3    Clarkin, O.M.4
  • 10
    • 0027128220 scopus 로고
    • Vertebral fractures
    • Cooper C, Melton LJ (1992) Vertebral fractures. BMJ 304(6842):1634-1635
    • (1992) BMJ , vol.304 , Issue.6842 , pp. 1634-1635
    • Cooper, C.1    Melton, L.J.2
  • 11
    • 0028301306 scopus 로고
    • Toxic effect of methylmetacrylate monomere on leukocytes and endothelial cells in vitro
    • Dahl OE, Garvik LJ, Lyberg T (1994) Toxic effect of methylmetacrylate monomere on leukocytes and endothelial cells in vitro. Acta Orthop Scand 65:147-153
    • (1994) Acta Orthop Scand , vol.65 , pp. 147-153
    • Dahl, O.E.1    Garvik, L.J.2    Lyberg, T.3
  • 12
    • 0027053705 scopus 로고
    • Hyperthermia induced damage to rat sciatic nerv assessed in vivo with functional methods and with electrophysiology
    • De Vrind HH, Wondergem J, Haveman J (1992) Hyperthermia induced damage to rat sciatic nerv assessed in vivo with functional methods and with electrophysiology. J Neurosci Methods 45:165-174
    • (1992) J Neurosci Methods , vol.45 , pp. 165-174
    • De Vrind, H.H.1    Wondergem, J.2    Haveman, J.3
  • 13
    • 0021712493 scopus 로고
    • Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit
    • Eriksson RA, Albrektsson T, Magnusson B (1984) Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit. Scand J Plast Reconstr Surg 18:261-268
    • (1984) Scand J Plast Reconstr Surg , vol.18 , pp. 261-268
    • Eriksson, R.A.1    Albrektsson, T.2    Magnusson, B.3
  • 14
    • 14944341603 scopus 로고    scopus 로고
    • Incidence of subsequent vertebral fracture after kyphoplasty
    • Fribourg D, Tang C, Sra P et al (2004) Incidence of subsequent vertebral fracture after kyphoplasty. Spine 29:2270-2276
    • (2004) Spine , vol.29 , pp. 2270-2276
    • Fribourg, D.1    Tang, C.2    Sra, P.3
  • 15
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • Galibert P, Deramont H, Rosat P et al (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166-168
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramont, H.2    Rosat, P.3
  • 16
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
    • Garfin SR, Yuan HA, Reiley MA (2001) New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine 26:1511-1515
    • (2001) Spine , vol.26 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 17
    • 0029942682 scopus 로고    scopus 로고
    • The clinical impact of vertebral fractures: Quality of life in women with osteoporosis
    • Gold DT (1996) The clinical impact of vertebral fractures: Quality of life in women with osteoporosis. Bone 18:185-189
    • (1996) Bone , vol.18 , pp. 185-189
    • Gold, D.T.1
  • 18
    • 43549118408 scopus 로고    scopus 로고
    • Calciumphosphate and polymethylmethacrylate cement in long term outcome after kyphoplasty of painful osteoporotic vertebral fractures
    • Grafe IA, Baier M, Nöldge G et al (2008) Calciumphosphate and polymethylmethacrylate cement in long term outcome after kyphoplasty of painful osteoporotic vertebral fractures. Spine 33(11): 1284-1290
    • (2008) Spine , vol.33 , Issue.11 , pp. 1284-1290
    • Grafe, I.A.1    Baier, M.2    Nöldge, G.3
  • 19
    • 0035054442 scopus 로고    scopus 로고
    • Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements
    • Heini PF, Berlemann U, Kaufmann M et al (2001) Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements. Eur Spine J 10:164-171
    • (2001) Eur Spine J , vol.10 , pp. 164-171
    • Heini, P.F.1    Berlemann, U.2    Kaufmann, M.3
  • 20
    • 0029967823 scopus 로고    scopus 로고
    • Advances in osteoporosis: Better identification of risk factors can reduce morbidity and mortality
    • Johnell O (1996) Advances in osteoporosis: Better identification of risk factors can reduce morbidity and mortality. J Intern Med 239:299-304
    • (1996) J Intern Med , vol.239 , pp. 299-304
    • Johnell, O.1
  • 21
    • 0033373395 scopus 로고    scopus 로고
    • Heat shock-induced necrosis and apoptosis in osteoblasts
    • Li S, Chien S, Branemark PI (1999) Heat shock-induced necrosis and apoptosis in osteoblasts. J Orthop Res 17:891-899
    • (1999) J Orthop Res , vol.17 , pp. 891-899
    • Li, S.1    Chien, S.2    Branemark, P.I.3
  • 22
    • 0037096636 scopus 로고    scopus 로고
    • Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty
    • Lim TH, Brebach GT, Renner SM et al (2002) Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27:1297-1302
    • (2002) Spine , vol.27 , pp. 1297-1302
    • Lim, T.H.1    Brebach, G.T.2    Renner, S.M.3
  • 23
    • 0031425488 scopus 로고    scopus 로고
    • Epidemiology of spinal osteoporosis
    • Melton LJ (1997) Epidemiology of spinal osteoporosis. Spine 22:2-11
    • (1997) Spine , vol.22 , pp. 2-11
    • Melton, L.J.1
  • 24
    • 29144511632 scopus 로고    scopus 로고
    • Clinical results of an open prospective study of a bis-GMA composite in percutaneous vertebral augmentation
    • Palussiere J, Berge J, Gangi A et al (2005) Clinical results of an open prospective study of a bis-GMA composite in percutaneous vertebral augmentation. Eur Spine J 14:982-991
    • (2005) Eur Spine J , vol.14 , pp. 982-991
    • Palussiere, J.1    Berge, J.2    Gangi, A.3
  • 25
    • 0002896535 scopus 로고
    • Orthopaedic prosthesis fixation
    • Bronzino JD (ed) CRC, Boca Raton
    • Park JB (1995) Orthopaedic prosthesis fixation. In: Bronzino JD (ed) The biomedical engineering handbook. CRC, Boca Raton, pp 704-724
    • (1995) The Biomedical Engineering Handbook , pp. 704-724
    • Park, J.B.1
  • 26
    • 0037648845 scopus 로고    scopus 로고
    • The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit. Finite-element analysis
    • Polikeit A, Nolte LP, Ferguson SJ (2003) The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit. Finite-element analysis. Spine 28:991-996
    • (2003) Spine , vol.28 , pp. 991-996
    • Polikeit, A.1    Nolte, L.P.2    Ferguson, S.J.3
  • 27
    • 77954540446 scopus 로고    scopus 로고
    • Bioceramic vertebral augmentation with a calcium sulphate/hydroxyapatite composite (Cerament™ Spinesupport) in vertebral compression fractures due to osteoporosis
    • (in press)
    • Rauschmann M, Vogel T, Verheyden A et al (2010) Bioceramic vertebral augmentation with a calcium sulphate/hydroxyapatite composite (Cerament™ Spinesupport) in vertebral compression fractures due to osteoporosis. Eur Spine J (in press)
    • (2010) Eur Spine J
    • Rauschmann, M.1    Vogel, T.2    Verheyden, A.3
  • 28
    • 0032227999 scopus 로고    scopus 로고
    • Osteoporosis: Epidemiology and risk assessment
    • Ross PD (1998) Osteoporosis: epidemiology and risk assessment. J Nutr Health Aging 2:178-183
    • (1998) J Nutr Health Aging , vol.2 , pp. 178-183
    • Ross, P.D.1
  • 29
    • 1942500920 scopus 로고    scopus 로고
    • In vivo evaluation of resorbable bone graft substitutes in a rabbit tibial defect model
    • Stubbs D, Deakin M, Chapman-Sheath P et al (2004) In vivo evaluation of resorbable bone graft substitutes in a rabbit tibial defect model. Biomaterials 25:5037-5044
    • (2004) Biomaterials , vol.25 , pp. 5037-5044
    • Stubbs, D.1    Deakin, M.2    Chapman-Sheath, P.3
  • 30
    • 33750571887 scopus 로고    scopus 로고
    • Balloon kyphoplasty and vertebroplasty for vertebral compression fracture - A comparative systematic review of efficacy and safety
    • Taylor RS, Taylor RJ, Fritzell P (2006) Balloon kyphoplasty and vertebroplasty for vertebral compression fracture - a comparative systematic review of efficacy and safety. Spine 31:2747-2755
    • (2006) Spine , vol.31 , pp. 2747-2755
    • Taylor, R.S.1    Taylor, R.J.2    Fritzell, P.3
  • 31
    • 0038376699 scopus 로고    scopus 로고
    • Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethylmethacrylate
    • Togawa D, Bauer TW, Liebermann ICH et al (2003) Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethylmethacrylate. Spine 28:1521-1527
    • (2003) Spine , vol.28 , pp. 1521-1527
    • Togawa, D.1    Bauer, T.W.2    Ich, L.3
  • 32
    • 33644801211 scopus 로고    scopus 로고
    • Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine - Percutaneous vertebroplasty and kyphoplasty
    • Togawa D, Kovacic JJ, Liebermann ICH et al (2006) Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine - percutaneous vertebroplasty and kyphoplasty. Spine 31:1-4
    • (2006) Spine , vol.31 , pp. 1-4
    • Togawa, D.1    Kovacic, J.J.2    Ich, L.3
  • 33
    • 33644867089 scopus 로고    scopus 로고
    • New fractures after vertebroplasty: Adjacent fractures occurs significantly sooner
    • Trout AT, Kallmes DF, Kaufmann TJ (2006) New fractures after vertebroplasty: adjacent fractures occurs significantly sooner. Am J Neuroradiol 27:217-223
    • (2006) Am J Neuroradiol , vol.27 , pp. 217-223
    • Trout, A.T.1    Kallmes, D.F.2    Kaufmann, T.J.3
  • 35
    • 0037231525 scopus 로고    scopus 로고
    • Response of a calcium sulfate bone graft substitute in a confined cancellous defect
    • Walsh WR, Morberg P, Yu Y et al (2003) Response of a calcium sulfate bone graft substitute in a confined cancellous defect. Clin Orthop 406:228-236
    • (2003) Clin Orthop , vol.406 , pp. 228-236
    • Walsh, W.R.1    Morberg, P.2    Yu, Y.3
  • 36
    • 0029922033 scopus 로고    scopus 로고
    • Vertebral fracture epidemiology
    • Wasnich U (1996) Vertebral fracture epidemiology. Bone 18:1791-1796
    • (1996) Bone , vol.18 , pp. 1791-1796
    • Wasnich, U.1
  • 37
    • 33845358253 scopus 로고    scopus 로고
    • Biomechanical evaluation of vertebroplasty and kyphoplasty with polymethylmetacrylate or calcium phosphate cement under cyclic loading
    • Wilke HJ, Mehnert U, Claes LE et al (2006) Biomechanical evaluation of vertebroplasty and kyphoplasty with polymethylmetacrylate or calcium phosphate cement under cyclic loading. Spine 31:2934-2941
    • (2006) Spine , vol.31 , pp. 2934-2941
    • Wilke, H.J.1    Mehnert, U.2    Claes, L.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.