Volumn 18, Issue 3, 2010, Pages 186-197

Potentiometric biosensing of glucose by fullerene-based silver selective electrodes

Author keywords

Ag+ selective electrode; fullerenes; glucose; sensors; silver nanoparticle

Indexed keywords

AG+-SELECTIVE ELECTRODE; BIOANALYSIS; BIOSENSING; BLOOD PLASMA; CALIBRATION GRAPHS; CONCENTRATION RANGES; GLUCOSE DETECTION; LIMIT OF DETECTION; LINEAR RANGE; LOWER DETECTION LIMIT; METHANOFULLERENES; PHOSPHATE BUFFERS; REPRODUCIBILITIES; RESPONSE TIME; SELECTIVE ELECTRODES; SELECTIVITY COEFFICIENT; SILVER NANOPARTICLES; SILVER-SELECTIVE ELECTRODES; WIDE PH RANGE;

EID: 77954256902     PISSN: 1536383X     EISSN: 15364046     Source Type: Journal    
DOI: 10.1080/15363831003782890     Document Type: Article
Times cited : (13)

References (29)
  • 1
    • 0034491295 scopus 로고    scopus 로고
    • The MiniMed continuous glucose monitoring system
    • Mastrototaro, J. J. (2000) The MiniMed continuous glucose monitoring system. Diabetes Technol. Ther., 2(Suppl 1): 13-18
    • (2000) Diabetes Technol. Ther. , vol.2 , Issue.SUPPL. 1 , pp. 13-18
    • Mastrototaro, J.J.1
  • 2
    • 1542439960 scopus 로고    scopus 로고
    • Performance assessment of the Medtronic-MiniMed continuous glucose monitoring system and its use for measurement of glycaemic control in type 1 diabetes
    • Sachedina, N. and Pickup, J. C. (2003) Performance assessment of the Medtronic-MiniMed continuous glucose monitoring system and its use for measurement of glycaemic control in type 1 diabetes. Diabet. Med., 20: 1012-1015
    • (2003) Diabet. Med. , vol.20 , pp. 1012-1015
    • Sachedina, N.1    Pickup, J.C.2
  • 3
    • 0033579205 scopus 로고    scopus 로고
    • Noninvasive glucose monitoring: Comprehensive clinical results
    • Tamada, J. A., Garg, S., Jovanovic, L., Pitzer, K. R., Fermi, S., and Potts, R. O. (1999) Noninvasive glucose monitoring: Comprehensive clinical results. JAMA, 282: 1839-1844
    • (1999) JAMA , vol.282 , pp. 1839-1844
    • Tamada, J.A.1    Garg, S.2    Jovanovic, L.3    Pitzer, K.R.4    Fermi, S.5    Potts, R.O.6
  • 4
    • 0032882086 scopus 로고    scopus 로고
    • Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
    • Garg, S. K., Potts, R. O., Ackerman, N. R., Fermi, S. J., Tamada, J. A., and Chase, H. P. (1999) Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care, 22: 1708-1714
    • (1999) Diabetes Care , vol.22 , pp. 1708-1714
    • Garg, S.K.1    Potts, R.O.2    Ackerman, N.R.3    Fermi, S.J.4    Tamada, J.A.5    Chase, H.P.6
  • 5
    • 14644390594 scopus 로고    scopus 로고
    • Glucose sensors: Present and future
    • r ed.; Defronzo, R., Ferrannini, E., Keen, H., and Zimmet, P. (eds.), John Wiley: Chichester, UK
    • r ed.; Defronzo, R., Ferrannini, E., Keen, H., and Zimmet, P. (eds.), John Wiley: Chichester, UK, pp. 1685-1694
    • (2004) International Textbook of Diabetes , pp. 1685-1694
    • Pickup, J.C.1
  • 6
    • 34548260353 scopus 로고    scopus 로고
    • Enzymatic detection of glucose using fluoride-selective electrodes with polymeric membranes
    • Gòrski, Ł., Klimaszewska, D., Pietrzak, M., and Malinowska, E. (2007) Enzymatic detection of glucose using fluoride-selective electrodes with polymeric membranes. Anal. Bioanal. Chem., 389: 533-539
    • (2007) Anal. Bioanal. Chem. , vol.389 , pp. 533-539
    • Gòrski, Ł.1    Klimaszewska, D.2    Pietrzak, M.3    Malinowska, E.4
  • 7
    • 34247356089 scopus 로고    scopus 로고
    • Determination of glucose using a coupled-enzymatic reaction with new fluoride selective optical sensing polymeric film coated in microtiter plate wells
    • Abd-Rabboh, H. S. M. and Meyerhoff, M. E. (2007) Determination of glucose using a coupled-enzymatic reaction with new fluoride selective optical sensing polymeric film coated in microtiter plate wells. Talanta, 72: 1129-1133
    • (2007) Talanta , vol.72 , pp. 1129-1133
    • Abd-Rabboh, H.S.M.1    Meyerhoff, M.E.2
  • 8
    • 8144226471 scopus 로고    scopus 로고
    • Preparation and application of a new glucose sensor based on iodide ion selective electrode
    • Kalayci, S., Somer, G., and Ekmekci, G. (2005) Preparation and application of a new glucose sensor based on iodide ion selective electrode. Talanta, 65: 87-91.
    • (2005) Talanta , vol.65 , pp. 87-91
    • Kalayci, S.1    Somer, G.2    Ekmekci, G.3
  • 9
    • 51649102251 scopus 로고    scopus 로고
    • New silver selective electrode fabricated from benzothiazole calix[4]arene: Speciation analysis of silver nanoparticles
    • Ngeontae, W., Janrungroatsakul, W., Morakot, N., Aeungmaitrepirom, W., and Tuntulani, T. (2008) New silver selective electrode fabricated from benzothiazole calix[4]arene: Speciation analysis of silver nanoparticles. Sens. Actuators B, 134: 377-385
    • (2008) Sens. Actuators B , vol.134 , pp. 377-385
    • Ngeontae, W.1    Janrungroatsakul, W.2    Morakot, N.3    Aeungmaitrepirom, W.4    Tuntulani, T.5
  • 10
    • 0034738701 scopus 로고    scopus 로고
    • Silver(I) ion selective PVC membrane based on bis-pyridine tetramide macrocycle
    • Mahajan, R. K. and Parkash, O. (2000) Silver(I) ion selective PVC membrane based on bis-pyridine tetramide macrocycle. Talanta, 52: 691-693
    • (2000) Talanta , vol.52 , pp. 691-693
    • Mahajan, R.K.1    Parkash, O.2
  • 11
    • 0037127502 scopus 로고    scopus 로고
    • Calix[2] furano[2]pyrrole and related compounds as the neutral carrier in silver ion-selective electrode
    • Kim, S. M., Chung, H. J., Paeng, K.-J., Lee, C.-H., Choi, H. N., and Lee, W.-Y. (2002) Calix[2] furano[2]pyrrole and related compounds as the neutral carrier in silver ion-selective electrode. Anal. Chim. Acta, 453: 81-88
    • (2002) Anal. Chim. Acta , vol.453 , pp. 81-88
    • Kim, S.M.1    Chung, H.J.2    Paeng, K.-J.3    Lee, C.-H.4    Choi, H.N.5    Lee, W.-Y.6
  • 12
    • 33644915290 scopus 로고    scopus 로고
    • 5, 10, 15-Tris(penta-fluorophenyl)corrole as highly selective neutral carrier for a silver ion-sensitive electrode
    • Zhang, X.-B., Han, Z.-X., Fang, Z.-H., Shen, G.-L., and Yu, R.-Q. (2006) 5, 10, 15-Tris(penta-fluorophenyl)corrole as highly selective neutral carrier for a silver ion-sensitive electrode. Anal. Chim. Acta, 562: 210-215
    • (2006) Anal. Chim. Acta , vol.562 , pp. 210-215
    • Zhang, X.-B.1    Han, Z.-X.2    Fang, Z.-H.3    Shen, G.-L.4    Yu, R.-Q.5
  • 13
    • 18844450174 scopus 로고    scopus 로고
    • Silver(I) ion selective ionophores containing dithiocarbamoyl moieties on steroid backbone
    • Kim, B. Y, Hong, H. P., Cho, K. T., On, J. H., Jun, Y M., Jeong, I. S., Cha, G. S., and Nam, H. (2005) Silver(I) ion selective ionophores containing dithiocarbamoyl moieties on steroid backbone. Talanta, 66: 794-804.
    • (2005) Talanta , vol.66 , pp. 794-804
    • Kim, B.Y.1    Hong, H.P.2    Cho, K.T.3    On, J.H.4    Jun, Y.M.5    Jeong, I.S.6    Cha, G.S.7    Nam, H.8
  • 14
    • 33847017273 scopus 로고    scopus 로고
    • Silver ion-selective electrodes based on bis(dialkyldithiocarba-mates) as neutral ionophores
    • Yan, Z., Lu, Y, and Li, X. (2007) Silver ion-selective electrodes based on bis(dialkyldithiocarba-mates) as neutral ionophores. Sens. Actuators B, 122: 174-181
    • (2007) Sens. Actuators B , vol.122 , pp. 174-181
    • Yan, Z.1    Lu, Y.2    Li, X.3
  • 16
    • 0031327809 scopus 로고    scopus 로고
    • Synthesis and H NMR studies of vinyl-substituted calix[4]arene derivatives: Enhanced cation-p interactions with extended calix[4] arene p-systems
    • Lhotak, P., Nakamura, R., and Shinkai, S. (1997) Synthesis and H NMR studies of vinyl-substituted calix[4]arene derivatives: Enhanced cation-p interactions with extended calix[4] arene p-systems. Supramol. Chem., 8: 333-344
    • (1997) Supramol. Chem. , vol.8 , pp. 333-344
    • Lhotak, P.1    Nakamura, R.2    Shinkai, S.3
  • 18
    • 1842663025 scopus 로고    scopus 로고
    • Synthesis and receptor properties of calix[4]arene-bisphenol-A copolymers
    • Dondoni, A., Ghiglione, C, Marra, A., and Scoponi, M. (1997) Synthesis and receptor properties of calix[4]arene-bisphenol-A copolymers. Chem. Commun., 673-674
    • (1997) Chem. Commun. , pp. 673-674
    • Dondoni, A.1    Ghiglione, C.2    Marra, A.3    Scoponi, M.4
  • 19
    • 0002699887 scopus 로고    scopus 로고
    • 'Soft' calixarenes-structural aspects of calixarene allyl ethers and of thiacalixarene synthesis
    • Delaigue, X., Harrowfield, J. M., Hosseini, M. W., Mocerino, M., Skelton, B. W., and White, A. H. (1998) 'Soft' calixarenes-structural aspects of calixarene allyl ethers and of thiacalixarene synthesis. Aust. J. Chem., 51: 111-121
    • (1998) Aust. J. Chem. , vol.51 , pp. 111-121
    • Delaigue, X.1    Harrowfield, J.M.2    Hosseini, M.W.3    Mocerino, M.4    Skelton, B.W.5    White, A.H.6
  • 20
    • 0001060066 scopus 로고    scopus 로고
    • Ionophores and receptors using cation-p interactions: Collarenes
    • Choi, H. S., Suh, S. B., Cho, S. J., and Kim, K. S. (1998) Ionophores and receptors using cation-p interactions: Collarenes. Proc. Natl. Acad. Sci. USA, 95: 12094-12099
    • (1998) Proc. Natl. Acad. Sci. USA , vol.95 , pp. 12094-12099
    • Choi, H.S.1    Suh, S.B.2    Cho, S.J.3    Kim, K.S.4
  • 21
    • 0034332646 scopus 로고    scopus 로고
    • Silver ion-selective electrodes using p-coordinate calix[4]arene derivatives as soft neutral carriers
    • Kimaura, K., Yajima, S., Tatsumi, K., Yokoyama, M., and Oue, M. (2000) Silver ion-selective electrodes using p-coordinate calix[4]arene derivatives as soft neutral carriers. Anal. Chem., 72: 5290-5294
    • (2000) Anal. Chem. , Issue.72 , pp. 5290-5294
    • Kimaura, K.1    Yajima, S.2    Tatsumi, K.3    Yokoyama, M.4    Oue, M.5
  • 23
    • 0000421151 scopus 로고    scopus 로고
    • The molecular world cup: Synthesis of a fullerene-calix[4]arene conjugate containing two malonamide substituents within the upper rim
    • Hirsch, A. and Soi, A. (1998) The molecular world cup: Synthesis of a fullerene-calix[4]arene conjugate containing two malonamide substituents within the upper rim. New J. Chem., 12: 1337-1339
    • (1998) New J. Chem. , vol.12 , pp. 1337-1339
    • Hirsch, A.1    Soi, A.2
  • 24
    • 47749085138 scopus 로고    scopus 로고
    • Fullerene-based electrochemical buffer layer for ionselective electrodes
    • Fouskaki, M. and Chaniotakis, N. (2008) Fullerene-based electrochemical buffer layer for ionselective electrodes. Analyst, 133: 1072-1075
    • (2008) Analyst , vol.133 , pp. 1072-1075
    • Fouskaki, M.1    Chaniotakis, N.2
  • 26
    • 0032541274 scopus 로고    scopus 로고
    • Regioselective synthesis of trans-1 fullerene bis-adducts directed by a crown ether tether: Alkali metal cation modulated redox properties of fullerene-crown ether conjugates
    • Bourgeois, J.-P., Echegoyen, L., Fibbioli, M., Pretsch, E., and Diederich, F. (1998) Regioselective synthesis of trans-1 fullerene bis-adducts directed by a crown ether tether: Alkali metal cation modulated redox properties of fullerene-crown ether conjugates. Angew. Chem., Int. Ed. Engl., 37: 2118-2121
    • (1998) Angew. Chem. Int. Ed. Engl. , vol.37 , pp. 2118-2121
    • Bourgeois, J.-P.1    Echegoyen, L.2    Fibbioli, M.3    Pretsch, E.4    Diederich, F.5
  • 27
    • 11244253689 scopus 로고    scopus 로고
    • Potentiometric performance of silver ion-selective electrodes based on tridentate Schiff base derivatives
    • Ueda, M., Saito, T., Fujimori, K., Moriuchi, T., and Shibutani, Y. (2004) Potentiometric performance of silver ion-selective electrodes based on tridentate Schiff base derivatives. Anal. Sci., 20: 1649-1653
    • (2004) Anal. Sci. , vol.20 , pp. 1649-1653
    • Ueda, M.1    Saito, T.2    Fujimori, K.3    Moriuchi, T.4    Shibutani, Y.5
  • 28
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrodes recommended methods for reporting Kpot values
    • Umezawa, Y., Umezawa, K., and Sato, H. (1995) Selectivity coefficients for ion-selective electrodes recommended methods for reporting Kpot values. Pure Appl. Chem., 6: 507-516
    • (1995) Pure Appl. Chem. , vol.6 , pp. 507-516
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.