1
-
-
0036555399
-
Modern approach of diagnosis and management of acute flank pain: Review of all imaging modalities
-
Heidenreich A, Desgrandschamps F, Terrier F. Modern approach of diagnosis and management of acute flank pain: review of all imaging modalities. Eur Urol. 2002;41:351-362.
-
(2002)
Eur Urol
, vol.41
, pp. 351-362
-
-
Heidenreich, A.1
Desgrandschamps, F.2
Terrier, F.3
-
2
-
-
33947704171
-
Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic
-
Poletti PA, Platon A, Rutschmann OT, et al. Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic. Am J Roentge-nol. 2007;188:927-933.
-
(2007)
Am J Roentge-nol
, vol.188
, pp. 927-933
-
-
Poletti, P.A.1
Platon, A.2
Rutschmann, O.T.3
-
3
-
-
17644389579
-
Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: Phantom and clinical studies
-
Kalra MK, Maher MM, D'Souza RV, et al. Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies. Radiology. 2005;235:523-529.
-
(2005)
Radiology
, vol.235
, pp. 523-529
-
-
Kalra, M.K.1
Maher, M.M.2
D'Souza, R.V.3
-
4
-
-
0035515936
-
Acute renal colic: Value of unenhanced spiral computed tomography compared with intravenous urography
-
Wong SK, Ng LG, Tan BS, et al. Acute renal colic: value of unenhanced spiral computed tomography compared with intravenous urography. Ann Acad Med Singapore. 2001;30:568-572.
-
(2001)
Ann Acad Med Singapore
, vol.30
, pp. 568-572
-
-
Wong, S.K.1
Ng, L.G.2
Tan, B.S.3
-
5
-
-
21544480007
-
Determination of the chemical composition of urinary calculi by noncontrast spiral computerized tomography
-
Sheir KZ, Mansour O, Madbouly K, et al. Determination of the chemical composition of urinary calculi by noncontrast spiral computerized tomography. Urol Res. 2005;33:99-104.
-
(2005)
Urol Res
, vol.33
, pp. 99-104
-
-
Sheir, K.Z.1
Mansour, O.2
Madbouly, K.3
-
6
-
-
34247267196
-
In-vivo relation between CT attenuation value and shockwave fragmentation
-
Hurtado F, Gutierrez J, Castano-Tostado E, et al. In-vivo relation between CT attenuation value and shockwave fragmentation. J Endourol. 2007;21:343-346.
-
(2007)
J Endourol
, vol.21
, pp. 343-346
-
-
Hurtado, F.1
Gutierrez, J.2
Castano-Tostado, E.3
-
7
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16:256-268.
-
(2006)
Eur Radiol
, vol.16
, pp. 256-268
-
-
Flohr, T.G.1
McCollough, C.H.2
Bruder, H.3
-
8
-
-
36148936386
-
Noninvasive differentiation of uric acid versus non-uric acid kidney stones using Dual-Energy CT
-
Primak AN, Fletcher JG, Vrtiska TJ, et al. Noninvasive differentiation of uric acid versus non-uric acid kidney stones using Dual-Energy CT. Acad Radiol. 2007;14:1441-1447.
-
(2007)
Acad Radiol
, vol.14
, pp. 1441-1447
-
-
Primak, A.N.1
Fletcher, J.G.2
Vrtiska, T.J.3
-
9
-
-
39749113025
-
Characterization of human renal stones with MDCT: Advantage of dual energy and limitations due to respiratory motion
-
Grosjean R, Sauer B, Guerra RM, et al. Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion. Am J Roentgenol. 2008;190:720-728.
-
(2008)
Am J Roentgenol
, vol.190
, pp. 720-728
-
-
Grosjean, R.1
Sauer, B.2
Guerra, R.M.3
-
10
-
-
38149109994
-
Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience
-
Graser A, Johnson TR, Bader M, et al. Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol. 2008; 43:112-119.
-
(2008)
Invest Radiol
, vol.43
, pp. 112-119
-
-
Graser, A.1
Johnson, T.R.2
Bader, M.3
-
11
-
-
48349118166
-
Dual-energy computed tomography for the differentiation of uric acid stones: Ex vivo performance evaluation
-
Stolzmann P, Scheffel H, Rentsch K, et al. Dual-energy computed tomography for the differentiation of uric acid stones: ex vivo performance evaluation. Urol Res. 2008;36:133-138.
-
(2008)
Urol Res
, vol.36
, pp. 133-138
-
-
Stolzmann, P.1
Scheffel, H.2
Rentsch, K.3
-
12
-
-
67349191462
-
Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol
-
Thomas C, Patschan O, Ketelsen D, et al. Dual-energy CT for the characterization of urinary calculi: in vitro and in vivo evaluation of a low-dose scanning protocol. Eur Radiol. 2009;19:1553-1559.
-
(2009)
Eur Radiol
, vol.19
, pp. 1553-1559
-
-
Thomas, C.1
Patschan, O.2
Ketelsen, D.3
-
13
-
-
62649160055
-
Renal stone assessment with dual-energy multidetector CT and advanced postprocessing techniques: Improved characterization of renal stone composition\pilot study
-
Boll DT, Patil NA, Paulson EK, et al. Renal stone assessment with dual-energy multidetector CT and advanced postprocessing techniques: improved characterization of renal stone composition\pilot study. Radiology. 2009; 250:813-820.
-
(2009)
Radiology
, vol.250
, pp. 813-820
-
-
Boll, D.T.1
Patil, N.A.2
Paulson, E.K.3
-
14
-
-
59249098264
-
Dual energy CT: Preliminary observations and potential clinical applications in the abdomen
-
Graser A, Johnson TR, Chandarana H, et al. Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol. 2008;19:13-23.
-
(2008)
Eur Radiol
, vol.19
, pp. 13-23
-
-
Graser, A.1
Johnson, T.R.2
Chandarana, H.3
-
15
-
-
63849101176
-
Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
-
Primak AN, Ramirez Giraldo JC, Liu X, et al. Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration. Med Phys. 2009;36:1359-1369.
-
(2009)
Med Phys
, vol.36
, pp. 1359-1369
-
-
Primak, A.N.1
Ramirez Giraldo, J.C.2
Liu, X.3
-
16
-
-
0031929709
-
Accurate determination of chemical composition of urinary calculi by spiral computerized tomography
-
Mostafavi MR, Ernst RD, Saltzman B. Accurate determination of chemical composition of urinary calculi by spiral computerized tomography. J Urol. 1998;159:673-675.
-
(1998)
J Urol
, vol.159
, pp. 673-675
-
-
Mostafavi, M.R.1
Ernst, R.D.2
Saltzman, B.3
-
17
-
-
4143066033
-
Spiral computed tomography: Role in determination of chemical compositions of pure and mixed urinary stones\an in vitro study
-
Deveci S, Coskun M, Tekin MI, et al. Spiral computed tomography: role in determination of chemical compositions of pure and mixed urinary stones\an in vitro study. Urology. 2004;64:237-240.
-
(2004)
Urology
, vol.64
, pp. 237-240
-
-
Deveci, S.1
Coskun, M.2
Tekin, M.I.3
-
18
-
-
67651047052
-
The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography
-
Sommer WH, Johnson TR, Becker CR, et al. The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography. Invest Radiol. 2009;44:285-292.
-
(2009)
Invest Radiol
, vol.44
, pp. 285-292
-
-
Sommer, W.H.1
Johnson, T.R.2
Becker, C.R.3
-
19
-
-
67651037373
-
Cervical and cranial computed tomo-graphic angiography with automated bone removal: Dual energy computed tomography versus standard computed tomography
-
Morhard D, Fink C, Graser A, et al. Cervical and cranial computed tomo-graphic angiography with automated bone removal: dual energy computed tomography versus standard computed tomography. Invest Radiol. 2009;44: 293-297.
-
(2009)
Invest Radiol
, vol.44
, pp. 293-297
-
-
Morhard, D.1
Fink, C.2
Graser, A.3
-
20
-
-
67651119947
-
Carotid computed tomography angiog-raphy with automated bone suppression: A comparative study between dual energy and bone subtraction techniques
-
Lell MM, Kramer M, Klotz E, et al. Carotid computed tomography angiog-raphy with automated bone suppression: a comparative study between dual energy and bone subtraction techniques. Invest Radiol. 2009;44:322-328.
-
(2009)
Invest Radiol
, vol.44
, pp. 322-328
-
-
Lell, M.M.1
Kramer, M.2
Klotz, E.3
-
21
-
-
77950342321
-
Automatic bone and plaque removal using dual energy CT for head and neck angiography: Feasibility and initial performance evaluation
-
June 10. [Epub ahead of print]
-
Thomas C, Korn A, Krauss B, et al. Automatic bone and plaque removal using dual energy CT for head and neck angiography: feasibility and initial performance evaluation. Eur J Radiol. 2009 June 10. [Epub ahead of print]
-
(2009)
Eur J Radiol
-
-
Thomas, C.1
Korn, A.2
Krauss, B.3
-
22
-
-
67650901483
-
Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: Utility and comparison with digital subtraction angiography
-
Uotani K, Watanabe Y, Higashi M, et al. Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography. Eur Radiol. 2009;19:2060-2065.
-
(2009)
Eur Radiol
, vol.19
, pp. 2060-2065
-
-
Uotani, K.1
Watanabe, Y.2
Higashi, M.3
-
23
-
-
36248997114
-
Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease
-
Scheffel H, Stolzmann P, Frauenfelder T, et al. Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease. Invest Radiol. 2007;42:823-829.
-
(2007)
Invest Radiol
, vol.42
, pp. 823-829
-
-
Scheffel, H.1
Stolzmann, P.2
Frauenfelder, T.3
-
24
-
-
43649084259
-
Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: A phantom study
-
Takahashi N, Hartman RP, Vrtiska TJ, et al. Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. Am J Roentgenol. 2008;190:1169-1173.
-
(2008)
Am J Roentgenol
, vol.190
, pp. 1169-1173
-
-
Takahashi, N.1
Hartman, R.P.2
Vrtiska, T.J.3
-
25
-
-
65349110338
-
Image fusion in dual energy computed tomography: Effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography
-
Behrendt FF, Schmidt B, Plumhans C, et al. Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography. Invest Radiol. 2009;44:1-6.
-
(2009)
Invest Radiol
, vol.44
, pp. 1-6
-
-
Behrendt, F.F.1
Schmidt, B.2
Plumhans, C.3
-
26
-
-
77954089654
-
Single-phase Dual Energy CT allows for characterization of renal masses as benign or malignant
-
Graser A, Staehler M, Macari M, et al. Single-phase Dual Energy CT allows for characterization of renal masses as benign or malignant. Invest Radiol. 2010;45:399-405.
-
(2010)
Invest Radiol.
, vol.45
, pp. 399-405
-
-
Graser, A.1
Staehler, M.2
MacAri, M.3
|