메뉴 건너뛰기




Volumn 182, Issue 7, 2010, Pages 581-588

Suitability of semi-automated tumor response assessment of liver metastases using a dedicated software package

Author keywords

CT spiral; liver metastases; RECIST; semi automated segmentation; software; tumor response

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CHEMOTHERAPY; CLINICAL ARTICLE; COLORECTAL CANCER; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; DIGITAL CALIPER; FEMALE; FOLLOW UP; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; LIVER METASTASIS; MALE; MEDICAL INSTRUMENTATION; PRACTICE GUIDELINE; PRIORITY JOURNAL; RESPONSE EVALUATION CRITERIA IN SOLID TUMOR GUIDELINE; TUMOR VOLUME;

EID: 77953843479     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0029-1245193     Document Type: Article
Times cited : (16)

References (28)
  • 1
    • 0019365237 scopus 로고
    • Reporting results of cancer treatment
    • Miller A B., Hoogstraten B, Staquet M et al. Reporting results of cancer treatment. Cancer 1981 47 207-214
    • (1981) Cancer , vol.47 , pp. 207-214
    • Miller, A.B.1    Hoogstraten, B.2    Staquet, M.3
  • 2
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada
    • Therasse P, Arbuck S G., Eisenhauer E A. et al. New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J Natl Cancer Inst 2000 92 205-216
    • (2000) J Natl Cancer Inst , vol.92 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3
  • 3
    • 57849117384 scopus 로고    scopus 로고
    • New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
    • Eisenhauer E A., Therasse P, Bogaerts J et al. New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). Eur J Cancer 2009 45 228-247
    • (2009) Eur J Cancer , vol.45 , pp. 228-247
    • Eisenhauer, E.A.1    Therasse, P.2    Bogaerts, J.3
  • 4
    • 33644890197 scopus 로고    scopus 로고
    • Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
    • Marten K, Auer F, Schmidt S et al. Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria. Eur Radiol 2006 16 781-790
    • (2006) Eur Radiol , vol.16 , pp. 781-790
    • Marten, K.1    Auer, F.2    Schmidt, S.3
  • 5
    • 0038352143 scopus 로고    scopus 로고
    • Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    • Erasmus J J., Gladish G W., Broemeling L et al. Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: implications for assessment of tumor response. J Clin Oncol 2003 21 2574-2582
    • (2003) J Clin Oncol , vol.21 , pp. 2574-2582
    • Erasmus, J.J.1    Gladish, G.W.2    Broemeling, L.3
  • 6
    • 0037388483 scopus 로고    scopus 로고
    • Tumour size measurement in an oncology clinical trial: Comparison between off-site and on-site measurements
    • Belton A L., Saini S, Liebermann K et al. Tumour size measurement in an oncology clinical trial: comparison between off-site and on-site measurements. Clin Radiol 2003 58 311-314
    • (2003) Clin Radiol , vol.58 , pp. 311-314
    • Belton, A.L.1    Saini, S.2    Liebermann, K.3
  • 7
    • 0842345498 scopus 로고    scopus 로고
    • Volumetric measurements of pulmonary nodules at multi-row detector CT: In vivo reproducibility
    • Wormanns D, Kohl G, Klotz E et al. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 2004 14 86-92
    • (2004) Eur Radiol , vol.14 , pp. 86-92
    • Wormanns, D.1    Kohl, G.2    Klotz, E.3
  • 8
    • 66149132180 scopus 로고    scopus 로고
    • Semi-Automated Quantification of Hepatic Lesions in a Phantom
    • Keil S, Plumhans C, Behrendt F F. et al. Semi-Automated Quantification of Hepatic Lesions in a Phantom. Invest Radiol 2008 44 82-88
    • (2008) Invest Radiol , vol.44 , pp. 82-88
    • Keil, S.1    Plumhans, C.2    Behrendt, F.F.3
  • 9
    • 54049148579 scopus 로고    scopus 로고
    • Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria
    • Keil S, Behrendt F F., Stanzel S et al. Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria. Eur Radiol 2008 18 2456-2465
    • (2008) Eur Radiol , vol.18 , pp. 2456-2465
    • Keil, S.1    Behrendt, F.F.2    Stanzel, S.3
  • 10
    • 58249088928 scopus 로고    scopus 로고
    • Einfluss des Vaskularisationsgrades auf die automatische Segmentierung und Messung von Lebertumoren nach RECIST in einer biphasischen Multi-Slice-CT (MSCT)
    • Puesken M, Juergens K U., Edenfeld A et al. Einfluss des Vaskularisationsgrades auf die automatische Segmentierung und Messung von Lebertumoren nach RECIST in einer biphasischen Multi-Slice-CT (MSCT). Fortschr Röntgenstr 2009 181 67-73
    • (2009) Fortschr Röntgenstr , vol.181 , pp. 67-73
    • Puesken, M.1    Juergens, K.U.2    Edenfeld, A.3
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J M., Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 1 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0031684291 scopus 로고    scopus 로고
    • Liver volume in patients with or without chronic liver diseases
    • Lin X Z., Sun Y N., Liu Y H. et al. Liver volume in patients with or without chronic liver diseases. Hepatogastroenterology 1998 45 1069-1074
    • (1998) Hepatogastroenterology , vol.45 , pp. 1069-1074
    • Lin, X.Z.1    Sun, Y.N.2    Liu, Y.H.3
  • 13
    • 0029975750 scopus 로고    scopus 로고
    • Measurement error and correlation coefficients
    • Bland J M., Altman D G. Measurement error and correlation coefficients. Bmj 1996 313 41-42
    • (1996) Bmj , vol.313 , pp. 41-42
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 41149158204 scopus 로고    scopus 로고
    • Comparison of manual and automated size measurements of lung metastases on MDCT images: Potential influence on therapeutic decisions
    • Pauls S, Kurschner C, Dharaiya E et al. Comparison of manual and automated size measurements of lung metastases on MDCT images: potential influence on therapeutic decisions. Eur J Radiol 2008 66 19-26
    • (2008) Eur J Radiol , vol.66 , pp. 19-26
    • Pauls, S.1    Kurschner, C.2    Dharaiya, E.3
  • 15
    • 58249084811 scopus 로고    scopus 로고
    • Linear and volume measurements of pulmonary nodules at different CT dose levels intrascan and interscan analysis
    • Hein P A., Romano V C., Rogalla P et al. Linear and volume measurements of pulmonary nodules at different CT dose levels intrascan and interscan analysis. Fortschr Röntgenstr 2009 181 24-31
    • (2009) Fortschr Röntgenstr , vol.181 , pp. 24-31
    • Hein, P.A.1    Romano, V.C.2    Rogalla, P.3
  • 16
    • 35148874156 scopus 로고    scopus 로고
    • Quantitative CT-Verlaufskontrolle von Lebermalignomen nach RECIST und WHO im Vergleich zur Volumetrie
    • Heussel C P., Meier S, Wittelsberger S et al. Quantitative CT-Verlaufskontrolle von Lebermalignomen nach RECIST und WHO im Vergleich zur Volumetrie. Fortschr Röntgenstr 2007 179 958-964
    • (2007) Fortschr Röntgenstr , vol.179 , pp. 958-964
    • Heussel, C.P.1    Meier, S.2    Wittelsberger, S.3
  • 17
    • 0029769512 scopus 로고    scopus 로고
    • Analysis of interobserver and intraobserver variability in CT tumor measurements
    • Hopper K D., Kasales C J., Van Slyke M A. et al. Analysis of interobserver and intraobserver variability in CT tumor measurements. Am J Roentgenol 1996 167 851-854
    • (1996) Am J Roentgenol , vol.167 , pp. 851-854
    • Hopper, K.D.1    Kasales, C.J.2    Van Slyke, M.A.3
  • 18
    • 0033671429 scopus 로고    scopus 로고
    • CT assessment of tumour response to treatment: Comparison of linear, cross-sectional and volumetric measures of tumour size
    • Sohaib S A., Turner B, Hanson J A. et al. CT assessment of tumour response to treatment: comparison of linear, cross-sectional and volumetric measures of tumour size. Br J Radiol 2000 73 1178-1184
    • (2000) Br J Radiol , vol.73 , pp. 1178-1184
    • Sohaib, S.A.1    Turner, B.2    Hanson, J.A.3
  • 19
    • 0026892757 scopus 로고
    • Computed tomographic staging of esophageal carcinoma: A study on interobserver variation and correlation with pathological findings
    • Goei R, Lamers R J., Engelshove H A. et al. Computed tomographic staging of esophageal carcinoma: a study on interobserver variation and correlation with pathological findings. Eur J Radiol 1992 15 40-44
    • (1992) Eur J Radiol , vol.15 , pp. 40-44
    • Goei, R.1    Lamers, R.J.2    Engelshove, H.A.3
  • 20
    • 0035202667 scopus 로고    scopus 로고
    • The RECIST (Response Evaluation Criteria in Solid Tumors) criteria: Implications for diagnostic radiologists
    • Padhani A R., Ollivier L. The RECIST (Response Evaluation Criteria in Solid Tumors) criteria: implications for diagnostic radiologists. Br J Radiol 2001 74 983-986
    • (2001) Br J Radiol , vol.74 , pp. 983-986
    • Padhani, A.R.1    Ollivier, L.2
  • 21
    • 0031679831 scopus 로고    scopus 로고
    • A semi-automated program for volume measurement in focal hepatic lesions: A first clinical experience
    • De Vriendt G, Rigauts H, and M eeus L. A semi-automated program for volume measurement in focal hepatic lesions: a first clinical experience. J Belge Radiol 1998 81 181-183
    • (1998) J Belge Radiol , vol.81 , pp. 181-183
    • De Vriendt, G.1    Rigauts, H.2    L, M.E.3
  • 22
    • 41949136449 scopus 로고    scopus 로고
    • Automated CT volumetry of pulmonary metastases: The effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria
    • Marten K, Auer F, Schmidt S et al. Automated CT volumetry of pulmonary metastases: the effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria. Eur Radiol 2007 17 2561-2571
    • (2007) Eur Radiol , vol.17 , pp. 2561-2571
    • Marten, K.1    Auer, F.2    Schmidt, S.3
  • 23
    • 70149105545 scopus 로고    scopus 로고
    • RECIST and WHO criteria evaluation of cervical, thoracic and abdominal lymph nodes in patients with malignant lymphoma: Manual versus semi-automated measurement on standard MDCT slices
    • Keil S, Behrendt F F., Stanzel S et al. RECIST and WHO criteria evaluation of cervical, thoracic and abdominal lymph nodes in patients with malignant lymphoma: manual versus semi-automated measurement on standard MDCT slices. Fortschr Röntgenstr 2009 181 888-895
    • (2009) Fortschr Röntgenstr , vol.181 , pp. 888-895
    • Keil, S.1    Behrendt, F.F.2    Stanzel, S.3
  • 24
    • 52249100989 scopus 로고    scopus 로고
    • Lungenrundherdvolumetrie mit optimiertem Segmentierungsalgorithmus. Genauigkeit bei verschiedenen Schichtdicken verglichen mit ein-und zweidimensionalen Messungen
    • Vogel M N., Vonthein R, Schmucker S et al. Lungenrundherdvolumetrie mit optimiertem Segmentierungsalgorithmus. Genauigkeit bei verschiedenen Schichtdicken verglichen mit ein-und zweidimensionalen Messungen. Fortschr Röntgenstr 2008 180 791-797
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 791-797
    • Vogel, M.N.1    Vonthein, R.2    Schmucker, S.3
  • 25
    • 0030658087 scopus 로고    scopus 로고
    • Response rate accuracy in oncology trials: Reasons for interobserver variability. Groupe Francais dImmunotherapie of the Federation Nationale des Centres de Lutte Contre le Cancer
    • Thiesse P, Ollivier L, Di Stefano-Louineau D et al. Response rate accuracy in oncology trials: reasons for interobserver variability. Groupe Francais dImmunotherapie of the Federation Nationale des Centres de Lutte Contre le Cancer. J Clin Oncol 1997 15 3507-3514
    • (1997) J Clin Oncol , vol.15 , pp. 3507-3514
    • Thiesse, P.1    Ollivier, L.2    Di Stefano-Louineau, D.3
  • 26
    • 0036861177 scopus 로고    scopus 로고
    • Assessment of tumour response to chemotherapy for metastatic colorectal cancer: Accuracy of the RECIST criteria
    • Trillet-Lenoir V, Freyer G, Kaemmerlen P et al. Assessment of tumour response to chemotherapy for metastatic colorectal cancer: accuracy of the RECIST criteria. Br J Radiol 2002 75 903-908
    • (2002) Br J Radiol , vol.75 , pp. 903-908
    • Trillet-Lenoir, V.1    Freyer, G.2    Kaemmerlen, P.3
  • 27
    • 0344237226 scopus 로고    scopus 로고
    • Tumor response to chemotherapy: The validity and reproducibility of RECIST guidelines in NSCLC patients
    • Watanabe H, Yamamoto S, Kunitoh H et al. Tumor response to chemotherapy: the validity and reproducibility of RECIST guidelines in NSCLC patients. Cancer Sci 2003 94 1015-1020
    • (2003) Cancer Sci , vol.94 , pp. 1015-1020
    • Watanabe, H.1    Yamamoto, S.2    Kunitoh, H.3
  • 28
    • 0642372937 scopus 로고    scopus 로고
    • Measuring response in solid tumors: Comparison of RECIST and WHO response criteria
    • Park J O., Lee S I., Song S Y. et al. Measuring response in solid tumors: comparison of RECIST and WHO response criteria. Jpn J Clin Oncol 2003 33 533-537
    • (2003) Jpn J Clin Oncol , vol.33 , pp. 533-537
    • Park, J.O.1    Lee, S.I.2    Song, S.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.