메뉴 건너뛰기




Volumn 181, Issue 1, 2009, Pages 67-73

Accuracy of liver lesion assessment using automated measurement and segmentation software in biphasic multislice CT (MSCT);Einfluss des vaskularisationsgrades auf die automatische segmentierung und messung von lebertumoren nach RECIST in einer biphasischen multi-slice-CT (MSCT)

Author keywords

CT spiral; Liver lesions; RECIST; Segmentation software; Volumetry

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; COMPUTER PROGRAM; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; HEPATIC ARTERY; HUMAN; LIVER ABSCESS; LIVER CANCER; LIVER CARCINOMA; LIVER CIRCULATION; LIVER CYST; LIVER DISEASE; LIVER HEMANGIOMA; LIVER METASTASIS; LYMPHOMA; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PORTAL VEIN; PRIORITY JOURNAL; BLOOD FLOW VELOCITY; CONE BEAM COMPUTED TOMOGRAPHY; CYST; DIFFERENTIAL DIAGNOSIS; HEMANGIOMA; IMAGE ENHANCEMENT; IMAGE PROCESSING; LIVER; LIVER CELL CARCINOMA; LIVER TUMOR; METASTASIS; METHODOLOGY; MIDDLE AGED; NEOVASCULARIZATION (PATHOLOGY); PHYSIOLOGY; RADIOGRAPHY; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; VASCULARIZATION;

EID: 58249088928     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-2008-1027848     Document Type: Article
Times cited : (19)

References (19)
  • 1
    • 0019365237 scopus 로고
    • Reporting results of cancer traetment
    • Miller AB, Hogestraeten B, Staquet M et al. Reporting results of cancer traetment. Cancer 1981; 47: 207-214
    • (1981) Cancer , vol.47 , pp. 207-214
    • Miller, A.B.1    Hogestraeten, B.2    Staquet, M.3
  • 4
    • 33644890197 scopus 로고    scopus 로고
    • Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
    • DOI 10.1007/s00330-005-0036-x
    • Marten K, Auer F, Schmidt S et al. Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria. Eur Radiol 2006; 16: 781-790 (Pubitemid 43380236)
    • (2006) European Radiology , vol.16 , Issue.4 , pp. 781-790
    • Marten, K.1    Auer, F.2    Schmidt, S.3    Kohl, G.4    Rummeny, E.J.5    Engelke, C.6
  • 5
    • 40149092494 scopus 로고    scopus 로고
    • Computer-aided detection in CT colonography: Initial clinical experience using a prototype system
    • Graser A, Kolligs FT, Mang T et al. Computer-aided detection in CT colonography: initial clinical experience using a prototype system. Eur Radiol 2007; 17: 2608-2615
    • (2007) Eur Radiol , vol.17 , pp. 2608-2615
    • Graser, A.1    Kolligs, F.T.2    Mang, T.3
  • 6
    • 0036828526 scopus 로고    scopus 로고
    • Colonic polyps: Complementary role of computer-aided detection in CT colonography
    • Summers RM, Jerebko AK, Franaszek M et al. Colonic polyps: complemetary role of computer-aided detection in CT colonography. Radiology 2002; 225: 391-399 (Pubitemid 35239238)
    • (2002) Radiology , vol.225 , Issue.2 , pp. 391-399
    • Summers, R.M.1    Jerebko, A.K.2    Franaszek, M.3    Malley, J.D.4    Johnson, C.D.5
  • 7
    • 0038417130 scopus 로고    scopus 로고
    • Radiological measurement of breast cancer metastases to lung and liver: Comparison between WHO (bidimensional) and RECIST (unidimensional) guidelines
    • DOI 10.1097/00004728-200305000-00014
    • Prasad SR, Saini S, Sumner JE et al. Radiological measurements of breast cancer metastases to lung and liver: comparison between WHO (bidimensional) and RECIST (unidimensional) guidelines. J Comput Assist Tomogr 2003; 27: 380-384 (Pubitemid 36793188)
    • (2003) Journal of Computer Assisted Tomography , vol.27 , Issue.3 , pp. 380-384
    • Prasad, S.R.1    Saini, S.2    Sumner, J.E.3    Hahn, P.F.4    Sahani, D.5    Boland, G.W.6
  • 8
    • 0031059383 scopus 로고    scopus 로고
    • Size quantification of liver metastases in patients undergoing cancer treatment: Reproducibility of one-, two-, and three-dimensional measurements determined with spiral CT
    • van Hoe L, van Cutsem E, Vergote I et al. Size quantification of liver-metastases in patients undergoing cancer treatment: reproducibility of one-, two-, and three-dimensional measurements determined with spiral CT. Radiology 1997; 202: 671-675 (Pubitemid 27093435)
    • (1997) Radiology , vol.202 , Issue.3 , pp. 671-675
    • Van Hoe, L.1    Van Cutsem, E.2    Vergote, I.3    Baert, A.L.4    Bellon, E.5    Dupont, P.6    Marchal, G.7
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland A, Altman D. Statistical methods for assessing agreement between twomethods of clinical measurement. Lancet 1986; 1: 307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 17044423012 scopus 로고    scopus 로고
    • Monitoring of liver metastases after stereotactic radiotherapy using low-MI contrast-enhanced ultrasound - Initial results
    • DOI 10.1007/s00330-004-2620-x
    • Krix M, Plathow C, Essig M et al. Monitoring of liver metastases after stereotactic radiotherapy using low-MI contrast-enhanced untrasound-initial results. Eur Radiol 2005; 15: 677-684 (Pubitemid 40500735)
    • (2005) European Radiology , vol.15 , Issue.4 , pp. 677-684
    • Krix, M.1    Plathow, C.2    Essig, M.3    Herfarth, K.4    Debus, J.5    Kauczor, H.-U.6    Delorme, S.7
  • 11
    • 3242802962 scopus 로고    scopus 로고
    • Perfusion CT in patients with advanced bronchial carcinomas: A novel chance for characterization and treatment monitoring?
    • Kiessling F, Boese J, Corvinus C et al. Perfusion CT in patients with advanced bronchial carcinomas: a novel chance for characterization and treatment monitoring? Eur Radiol 2004; 14: 1226-1233
    • (2004) Eur Radiol , vol.14 , pp. 1226-1233
    • Kiessling, F.1    Boese, J.2    Corvinus, C.3
  • 12
    • 33846942648 scopus 로고    scopus 로고
    • Radiofrewuenzablation von malignen Lebertumoren: Erlaubt ein volumetrischer Nekrose-/Tumor-Quotient eine Vorhersage zur lokalen Tumorkontrolle?
    • Kühl H, Stattaus J, Kühl B et al. Radiofrewuenzablation von malignen Lebertumoren: Erlaubt ein volumetrischer Nekrose-/Tumor-Quotient eine Vorhersage zur lokalen Tumorkontrolle? Fortschr Röntgenstr 2006; 178: 1243-1249
    • (2006) Fortschr Röntgenstr , vol.178 , pp. 1243-1249
    • Kühl, H.1    Stattaus, J.2    Kühl, B.3
  • 13
    • 0642372937 scopus 로고    scopus 로고
    • Measuring response in solid tumors: Comparison of RECIST and WHO response criteria
    • Park JO, Lee SI, Song SYet al. Measuring response in solid tumors: comparison of RECIST and WHO response criteria. Jpn J Clin Oncol 2003; 33: 533-537
    • (2003) Jpn J Clin Oncol , vol.33 , pp. 533-537
    • Park, J.O.1    Lee, S.I.2    Song, S.Y.3
  • 14
    • 38149124062 scopus 로고    scopus 로고
    • Vergleich uni- und bidimensionaler Messverfahren zur Beurteilung des Therapieansprechens bei der Behandlung solider Tumoren
    • 630-634
    • Hauth EAM, Stattaus J, Forsting M. Vergleich uni- und bidimensionaler Messverfahren zur Beurteilung des Therapieansprechens bei der Behandlung solider Tumoren. Radiologe 2007; 47: 628, 630-634
    • (2007) Radiologe , vol.47 , pp. 628
    • Hauth, E.A.M.1    Stattaus, J.2    Forsting, M.3
  • 15
    • 0036828529 scopus 로고    scopus 로고
    • CT tumor measurement for therapeutic response assessment: Comparison of unidimensional, bidimensional, and volumetric techniques - Initial observations
    • Prasad SR, Jhaveri KS, Saini S et al. CT tumor measurement for therapeutic response assessment: comparison of unidimensional, bidimensional, and volumetric techniques - initial observations. Radiology 2002; 225: 416-419 (Pubitemid 35239241)
    • (2002) Radiology , vol.225 , Issue.2 , pp. 416-419
    • Prasad, S.R.1    Jhaveri, K.S.2    Saini, S.3    Hahn, P.F.4    Halpern, E.F.5    Sumner, J.E.6
  • 17
    • 67949125564 scopus 로고    scopus 로고
    • Volumetric measurement of pulmonary nodules at multi-row detector CT: In vivo reproducibility
    • Wormanns D, Kohl G, Klotz E et al. Volumetric measurement of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 2005; 15: 203-212
    • (2005) Eur Radiol , vol.15 , pp. 203-212
    • Wormanns, D.1    Kohl, G.2    Klotz, E.3
  • 18
    • 10444278156 scopus 로고    scopus 로고
    • Comparison of treatment response classifications between unidimensional, bidimensional und volumetric measurements of metastatic lung lesions on chest computed tomography
    • Tran LN, Brown MS, Goldin JG et al. Comparison of treatment response classifications between unidimensional, bidimensional und volumetric measurements of metastatic lung lesions on chest computed tomography. Acad Radiol 2004; 11: 1355-1360
    • (2004) Acad Radiol , vol.11 , pp. 1355-1360
    • Tran, L.N.1    Brown, M.S.2    Goldin, J.G.3
  • 19
    • 0032961363 scopus 로고    scopus 로고
    • Liver metastasis: Comparison of 2 methods for reporting of disease in patients receiving chemotherapy
    • Garant M, Trudeau M, Reinhold C et al. Liver metastasis: comparison of 2 methods for reporting of disease in patients receiving chemotherapy. Can Assoc Radiol J 1999; 50: 13-16 (Pubitemid 29162144)
    • (1999) Canadian Association of Radiologists Journal , vol.50 , Issue.1 , pp. 13-16
    • Garant, M.1    Trudeau, M.2    Reinhold, C.3    Bret, P.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.